Searcharxiv⌕ Search

arXiv subjects

G. Quéméner

Publications and source records attributed to G. Quéméner.

At least 19 recordsLinked to original sources

d(e,e'p) Studies of Exclusive Deuteron Electro-Disintegration

The d(e,e'p) cross section was measured at momentum transfers $Q^2 = $ 0.8, 2.1 and 3.5 $(GeV/c)^2$ covering a wide range of proton kinematics at each $Q^2$ setting that made it possible to study this reaction as a function of missing momentum as well as a function of the neutron laboratory recoil angle $θ_{nq}$. Missing momentum distributions were determined for fixed values of $θ_{nq}$ up to missing momenta of 0.65 $GeV/c$. For the two larger momentum transfer settings, the characteristics of the experimental momentum distributions confirm the theoretical prediction that final state interactions (FSI) contribute maximally around a $θ_{nq} \sim 70^\circ$, while for $θ_{nq} < 45^\circ$ FSI are significantly reduced. The data at reduced FSI settings were best reproduced by calculations using the CD-Bonn potential wave functions.

nucl-ex↗

Backscattering Study of Electrons from 0.1 to 3.4 MeV

Benchmarking simulation codes for electron transport and scattering in matter is a crucial step for estimating uncertainties in many applications. However, experimental data for electron energies of a few MeV is scarce to make such comparisons. We report here the measurement and the quantitative analysis of backscattering probabilities of electrons in the energy range 0.1 to 3.4~MeV impinging on YAP:Ce scintillator. The setup consists of a $2\times 2π$ calorimeter which enables, in particular, the inclusion of large incidence angles. The results are used to benchmark various scattering models incorporated in Geant4, showing relative deviations smaller than 5% between experiment and simulations. They demonstrate the current rather high reliability of the simulations when employing appropriate electromagnetic Physics Lists.

nucl-ex↗

Determination of the moments of the proton charge density

A global analysis of proton electric form factor experimental data from Rosenbluth separation and low squared four-momentum transfer experiments is discussed for the evaluation of the spatial moments of the proton charge density based on the recently published integral method. Specific attention is paid to the evaluation of the systematic errors of the method, particularly the sensitivity to the choice of the mathematical expression of the form factor fitting function. Within this comprehensive analysis of proton electric form factor data, the moments of the proton charge density are determined for integer order moments, particularly: $\langle r^2 \rangle$=0.694(09)$_{Sta.}$(16)$_{Sys.}$~fm$^2$, $\langle r^3 \rangle$=0.870(46)$_{Sta.}$(80)$_{Sys.}$~fm$^3$, and $\langle r^4 \rangle$=1.47(25)$_{Sta.}$(45)$_{Sys.}$~fm$^4$.

nucl-ex↗

High precision measurement of the $^6$He half-life

The half-life of $^{6}$He has been measured using a low energy radioactive beam implanted in a YAP scintillator and recording decay events in a 4$π$ geometry. Events were time-stamped with a digital data acquisition system enabling a reliable control of dead-time effects and detector gain variations. The result, $T_{1/2} = (807.25 \pm 0.16_{\rm stat} \pm 0.11_{\rm sys}$)~ms, provides the most precise value obtained so far and is consistent with the only previous measurement having a precision smaller than 0.1%. This resolves the longstanding discrepancy previously observed between two sets of measurements.

nucl-ex↗

Mapping of the magnetic field to correct systematic effects in a neutron electric dipole moment experiment

Experiments dedicated to the measurement of the electric dipole moment of the neutron require outstanding control of the magnetic field uniformity. The neutron electric dipole moment (nEDM) experiment at the Paul Scherrer Institute uses a 199Hg co-magnetometer to precisely monitor magnetic field variations. This co-magnetometer, in the presence of field non-uniformity, is responsible for the largest systematic effect of this measurement. To evaluate and correct that effect, offline measurements of the field non-uniformity were performed during mapping campaigns in 2013, 2014 and 2017. We present the results of these campaigns, and the improvement the correction of this effect brings to the neutron electric dipole moment measurement.

physics.ins-det↗

OuroborosBEM: A fast multi-GPU microscopic Monte Carlo simulation for gaseous detectors and charged particle dynamics

The design of gaseous detectors for accelerator, particle and nuclear physics requires simulations relying on multi-physics aspects. In fact, these simulations deal with the dynamics of a large number of charged particles interacting in a gaseous medium immersed in the electric field generated by a more or less complex assembly of electrodes and dielectric materials. We report here on a homemade software, called OUROBOROSBEM, able to tackle the different features involved in such simulations. After solving the electrostatic problem for which a solver based on the boundary element method (BEM) has been implemented, particles are tracked and will microscopically interact with the gas medium. Dynamical effects have been included such as the electron-ion recombination process, the charging-up of the dielectric materials and other space charge effects that might alter the detector performances. These were made possible thanks to the nVidia CUDA language specifically optimised to run on Graphical Processor Units (GPUs) to minimize the computing times. Comparisons of the results obtained for parallel plate avalanche counters and GEM detectors to literature data on swarm parameters fully validate the performances of OUROBOROSBEM. Moreover, we were able to precisely reproduce the measured gains of single and double GEM detectors as a function of the applied voltage.

physics.ins-det↗

The design of the n2EDM experiment

We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnitude better sensitivity with provision for further substantial improvements. An overview is given of the experimental method and setup, the sensitivity requirements for the apparatus are derived, and its technical design is described.

physics.ins-det↗

Connecting spatial moments and momentum densities

The precision of experimental data and analysis techniques is a key feature of any discovery attempt. A striking example is the proton radius puzzle where the accuracy of the spectroscopy of muonic atoms challenges traditional electron scattering measurements. The present work proposes a novel method for the determination of spatial moments from densities expressed in the momentum space. This method provides a direct access to even, odd, and more generally any real, negative and positive moment with order larger than $-3$. As an illustration, the application of this method to the electric form factor of the proton is discussed in detail.

nucl-th↗

Optically Pumped Cs Magnetometers Enabling a High-Sensitivity Search for the Neutron Electric Dipole Moment

An array of sixteen laser-pumped scalar Cs magnetometers was part of the neutron electric dipole moment (nEDM) experiment taking data at the Paul Scherrer Institute in 2015 and 2016. It was deployed to measure the gradients of the experiment's magnetic field and to monitor their temporal evolution. The originality of the array lies in its compact design, in which a single near-infrared diode laser drives all magnetometers that are located in a high-vacuum chamber, with a selection of the sensors mounted on a high-voltage electrode. We describe details of the Cs sensors' construction and modes of operation, emphasizing the accuracy and sensitivity of the magnetic field readout. We present two applications of the magnetometer array directly beneficial to the nEDM experiment: (i) the implementation of a strategy to correct for the drift of the vertical magnetic field gradient and (ii) a procedure to homogenize the magnetic field. The first reduces the uncertainty of the new nEDM result. The second enables transverse neutron spin relaxation times exceeding 1500 s, improving the statistical sensitivity of the nEDM experiment by about 35% and effectively increasing the rate of nEDM data taking by a factor of 1.8.

physics.atom-ph↗

Simultaneous Measurements of the Beta Neutrino Angular Correlation in $^{32}$Ar Pure Fermi and Pure Gamow-Teller Transitions using Beta-Proton Coincidences

We report first time measurements of the beta-neutrino angular correlation based on the kinetic energy shift of protons emitted in parallel or anti-parallel directions with respect to the positron in the beta decay of $^{32}$Ar. This proof of principle experiment provided simultaneous measurements for the superallowed 0$^+$~$\rightarrow$~0$^+$ transition followed by a 3356~keV proton emission and for a Gamow-Teller transition followed by a 2123~keV proton emission. The results, respectively ${\tilde a_{βν}}=1.01(3)_{(stat)}(2)_{(syst)}$ and ${\tilde a_{βν}}=-0.22(9)_{(stat)}(2)_{(syst)}$, are found in agreement with the Standard Model. A careful analysis of the data shows that future measurements can reach a precision level of 10$^{-3}$ for both pure Fermi and pure Gamow-Teller decay channels, providing new constraints on both scalar and tensor weak interactions.

nucl-ex↗

Geometry optimisation of a transparent axisymmetric ion trap for the MORA project

In the frame of the project MORA (Matter's Origin from the Radio Activity of trapped and oriented ions), a transparent axially symmetric radio-frequency ion trap (MORATrap) was designed in order to measure the triple correlation parameter $D$ in nuclear $β-$decay of laser-polarised ions. The trap design was inspired from the LPCTrap geometry, operated at GANIL from 2005 to 2013. In a real (non-ideal) Paul trap, the quadrupole electric potential is not perfect leading to instabilities in ion motion and therefore affecting the overall trapping efficiency. This paper presents a numerical method aiming to optimise the geometry of a trap. It is applied to MORATrap in order to improve the trapping efficiency and to enlarge the axial transparent solid angle compared to LPCTrap. In the whole optimisation process, numerical computation of electric potential and field was carried out using an electrostatic solver based on boundary element method (BEM). The optimisation consisted in minimising an objective function (fitness function) depending on higher order multipoles of the potential. Finally, systematic changes of trap dimensions and electrode displacements were applied to investigate geometrical effects on the potential quality.

physics.ins-det↗

The open LPC Paul trap for precision measurements in beta decay

The LPCTrap experiment uses an open Paul trap which was built to enable precision measurements in the beta decay of radioactive ions. The initial goal was the precise measurement of the beta-neutrino angular correlation coefficient in the decay of 6He. Its geometry results from a careful optimization of the harmonic potential created by cylindrical electrodes. It supersedes previously considered geometries that presented a smaller detection solid angle to the beta particle and the recoiling ion. We describe here the methods which were used for the potential optimization, and we present the measured performances in terms of trapping time, cloud size and temperature, and space charge related limits. The properties of the ion cloud at equilibrium are well reproduced by a simple numerical simulation using hard sphere collisions, which additionally gives insights on the trapping loss mechanism. The interpretation for the observed trapping liftetimes is further corroborated by a model recently developed for ion clouds in Paul traps. The open trap shall serve other projects. It is currently used for commissioning purpose in the TRAPSENSOR experiment and is also considered in tests of the Standard Model involving the beta decay of polarized $^{23}$Mg and $^{39}$Ca ion in the frame of the MORA experiment. The latter tests require in-trap polarization of the ions and further optimization of the trapping and detection setup. Based on the results of the simulations and of their interpretations given by the model, different improvements of the trapping setup are discussed.

physics.ins-det↗

Measurement of the permanent electric dipole moment of the neutron

We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-199 co-magnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic field changes. The statistical analysis was performed on blinded datasets by two separate groups while the estimation of systematic effects profited from an unprecedented knowledge of the magnetic field. The measured value of the neutron EDM is $d_{\rm n} = (0.0\pm1.1_{\rm stat}\pm0.2_{\rm sys})\times10^{-26}e\,{\rm cm}$.

hep-ex↗

Magnetic field uniformity in neutron electric dipole moment experiments

Magnetic field uniformity is of the utmost importance in experiments to measure the electric dipole moment of the neutron. A general parametrization of the magnetic field in terms of harmonic polynomial modes is proposed, going beyond the linear-gradients approximation. We review the main undesirable effects of non-uniformities: depolarization of ultracold neutrons, and Larmor frequency shifts of neutrons and mercury atoms. The theoretical predictions for these effects were verified by dedicated measurements with the single-chamber nEDM apparatus installed at the Paul Scherrer Institute.

physics.ins-det↗

Merits and constraints of low-${\bm K^2}$ experimental data for the proton radius determination

The question of the determination of the proton charge radius $R_p$ from electron scattering data led to an unprecedented experimental effort for measurements of the electric form factor of the proton at low and very low momentum transfer in electron and muon elastic scattering. On the basis of basic properties of densities and fitting bias considerations, a procedure is developed in order to evaluate the impact of forthcoming data on $R_p$. Particularly, it is shown that a 0.1\% precision on these future cross section data is necessary to establish indisputably the $R_p$-value as determined from lepton scattering. The ProRad (Proton Radius) experiment at the PRAE (Platform for Research and Applications with Electrons) facility in Orsay is further discussed, especially the experimental method to meet this stringent constraint.

nucl-ex↗

The STEREO Experiment

The STEREO experiment is a very short baseline reactor antineutrino experiment aiming at testing the hypothesis of light sterile neutrinos as an explanation of the deficit of the observed neutrino interaction rate with respect to the predicted rate, known as the Reactor Antineutrino Anomaly. The detector center is located 10 m away from the compact, highly $^{235}$U enriched core of the research nuclear reactor of the Institut Laue Langevin in Grenoble, France. This paper describes the STEREO site, the detector components and associated shielding designed to suppress the external sources of background which were characterized on site. It reports the performances in terms of detector response and energy reconstruction.

physics.ins-det↗

Demonstration of sensitivity increase in mercury free-spin-precession magnetometers due to laser-based readout for neutron electric dipole moment searches

We report on a laser based $^{199}$Hg co-magnetometer deployed in an experiment searching for a permanent electric dipole moment of the neutron. We demonstrate a more than five times increased signal to-noise-ratio in a direct comparison measurement with its $^{204}$Hg discharge bulb-based predecessor. An improved data model for the extraction of important system parameters such as the degrees of absorption and polarization is derived. Laser- and lamp-based data-sets can be consistently described by the improved model which permits to compare measurements using the two different light sources and to explain the increase in magnetometer performance. The laser-based magnetometer satisfies the magnetic field sensitivity requirements for the next generation nEDM experiments.

physics.ins-det↗

Electron shakeoff following the \b{eta}+ decay of 19Ne+ and 35Ar+ trapped ions

The electron shakeoff of 19F and 35Cl atoms resulting from the \b{eta}+ decay of 19Ne+ and 35Ar+ ions has been investigated using a Paul trap coupled to a time of flight recoil-ion spectrometer. The charge-state distributions of the recoiling daughter nuclei were compared to theoretical calculations based on the sudden approximation and accounting for subsequent Auger processes. The excellent agreement obtained for 35Cl is not reproduced in 19F. The shortcoming is attributed to the inaccuracy of the independent particle model employed to calculate the primary shakeoff probabilities in systems with rather low atomic numbers. This calls for more elaborate calculations, including explicitly the electron-electron correlations.

nucl-ex↗