SearcharxivSearch

arXiv subjects

G. Randall

Publications and source records attributed to G. Randall.

5 recordsLinked to original sources

The DarkLight Experiment at TRIUMF

This paper reports on the commissioning of the DarkLight experiment at the ARIEL superconducting electron linear accelerator located at TRIUMF in Vancouver, Canada. DarkLight was designed to utilize the ARIEL electron beam to search for a new boson, $A^\prime$, which preferentially couples to leptons, with a mass in the range 13-17 MeV/$c^2$. Such a boson could be produced via the $e^-~X\rightarrow e^-~X~A^\prime$ process, and the resulting $A^\prime\rightarrow e^+~e^-$ decay used to reconstruct the invariant mass of the $A^\prime$. The $e^+e^-$ pair is detected using a pair of magnetic spectrometers. Each spectrometer is instrumented with two triple GEM detectors and a scintillating strip hodoscope to trigger the event readout. Electron beam energies between 10 and 30 MeV were used to commission the experiment with a 1$~\mu$m thick carbon target. With both spectrometer polarities set to select electrons, elastic and M{\o}ller scattering were used to examine detector performance and compare with predicted distributions from Monte Carlo simulations. Planned upgrades to the e-linac will allow searches to be made with beam energies up to 50 MeV using a 1$~\mu$m thick tantalum target.

physics.ins-det

Effects of Temperature Anneal Cycling on a Cryogenically Proton Irradiated CCD

Throughout a typical Earth orbit a satellite is constantly bombarded by radiation with trapped and solar protons being of particular concern as they gradually damage the focal plane devices throughout the mission and degrade their performance. To understand the impact the damage has on CCDs and how it varies with their thermal history a proton radiation campaign has been carried out using a CCD280. The CCD is irradiated at 153 K and gradually warmed to 188 K in 5 K increments with Fe55 X-ray, dark current and trap pumping images taken at 153 K after each anneal step. The results show that despite the trap landscape changing throughout the anneal it has little impact on parallel charge transfer inefficiency. This is thought to be because most traps are unaffected and a lot of those that do anneal only move from the continuum between distinct trap species and into a nearby divacancy trap 'peak' whose emission time constant is similar enough to still impact the CTI. In terms of using a CCD280 or similar devices in a mission the CTI being unaffected by thermal annealing up to 188 K means that any CTI correction needed as the radiation damage builds up does not have to take into account the thermal history of the focal plane. However, it is possible that a significant amount of annealing will occur at temperatures greater than 188 K and care should be taken when a mission is operating in this range to gather accurate pre-flight data.

physics.ins-det

Design and Operation of a Windowless Gas Target Internal to a Solenoidal Magnet for Use with a Megawatt Electron Beam

A windowless hydrogen gas target of nominal thickness $10^{19}$ cm$^{-2}$ is an essential component of the DarkLight experiment, which is designed to utilize the megawatt electron beam at an Energy Recovery Linac (ERL). The design of such a target is challenging because the pressure drops by many orders of magnitude between the central, high-density section of the target and the surrounding beamline, resulting in laminar, transitional, and finally molecular flow regimes. The target system was assembled and operated at Jefferson Lab's Low Energy Recirculator Facility (LERF) in 2016, and subsequently underwent several revisions and calibration tests at MIT Bates in 2017. The system at dynamic equilibrium was simulated in COMSOL to provide a better understanding of its optimal operation at other working points. We have determined that a windowless gas target with sufficiently high density for DarkLight's experimental needs is feasible in an ERL environment.

physics.ins-det

The Nab Experiment: A Precision Measurement of Unpolarized Neutron Beta Decay

Neutron beta decay is one of the most fundamental processes in nuclear physics and provides sensitive means to uncover the details of the weak interaction. Neutron beta decay can evaluate the ratio of axial-vector to vector coupling constants in the standard model, $\lambda = g_A / g_V$, through multiple decay correlations. The Nab experiment will carry out measurements of the electron-neutrino correlation parameter $a$ with a precision of $\delta a / a = 10^{-3}$ and the Fierz interference term $b$ to $\delta b = 3\times10^{-3}$ in unpolarized free neutron beta decay. These results, along with a more precise measurement of the neutron lifetime, aim to deliver an independent determination of the ratio $\lambda$ with a precision of $\delta \lambda / \lambda = 0.03\%$ that will allow an evaluation of $V_{ud}$ and sensitively test CKM unitarity, independent of nuclear models. Nab utilizes a novel, long asymmetric spectrometer that guides the decay electron and proton to two large area silicon detectors in order to precisely determine the electron energy and an estimation of the proton momentum from the proton time of flight. The Nab spectrometer is being commissioned at the Fundamental Neutron Physics Beamline at the Spallation Neutron Source at Oak Ridge National Lab. We present an overview of the Nab experiment and recent updates on the spectrometer, analysis, and systematic effects.

nucl-ex

The DarkLight Experiment: A Precision Search for New Physics at Low Energies

We describe the current status of the DarkLight experiment at Jefferson Laboratory. DarkLight is motivated by the possibility that a dark photon in the mass range 10 to 100 MeV/c$^2$ could couple the dark sector to the Standard Model. DarkLight will precisely measure electron proton scattering using the 100 MeV electron beam of intensity 5 mA at the Jefferson Laboratory energy recovering linac incident on a windowless gas target of molecular hydrogen. The complete final state including scattered electron, recoil proton, and e+e- pair will be detected. A phase-I experiment has been funded and is expected to take data in the next eighteen months. The complete phase-II experiment is under final design and could run within two years after phase-I is completed. The DarkLight experiment drives development of new technology for beam, target, and detector and provides a new means to carry out electron scattering experiments at low momentum transfers.

physics.ins-det