SearcharxivSearch

arXiv subjects

G. Rizzo

Publications and source records attributed to G. Rizzo.

15 recordsLinked to original sources

Development for the Belle II vertex detector upgrade with depleted monolithic active pixel sensors

The vertex detector upgrade project for the Belle II experiment, based on CMOS depleted monolithic active pixel sensor technology, is planned to be carried out in conjunction with the major modification of the interaction region of the SuperKEKB collider during Long Shutdown 2 from 2032 to 2034. The MAPS sensor, named OBELIX currently under development, is derived from the successor to TJ-Monopix2, with modifications implemented to ensure compatibility with the Belle II trigger system. The new vertex detector consists of two layers of four self-supported consecutive OBELIX sensors, and three layers of discrete OBELIX sensors mounted on mechanical support structures with readout flex circuits attached to the sensors. The detector is arranged cylindrically around the beam pipe at radii ranging from 14 mm to 140 mm. The minimization of the material budget is required in order to enhance physics performance. We present an overview of the project and its latest developments, with particular emphasis on the development of low-material-budget flex circuits employing aluminum conductors.

physics.ins-det

Application of exhaustive simulation flow for advanced performance prediction of monolithic active pixel sensors

Monolithic active pixel sensor (MAPS) developments have pushed the detection performance in various directions, especially relative to timing where nanosecond-level precision is now considered. This evolution calls for a simultaneous upgrade of the simulation tools. We have developed a simulation flow that covers steps from the signal creation in the sensitive volume to the output of the pixel digital logic that performs the time-of-arrival and time-over-threshold (ToA/ToT) measurements. This approach adds several new features to the traditional use the of the TCAD - Allpix Squared duo, among which : the integration of the pixel wells from the layout in order to precisely describe the pixel key characteristics such as leakage and punch-through currents and the coupling of Monte Carlo simulations (Allpix Squared) with high precision electrical simulations (SPICE). The first (Allpix Squared) for the precise description of the current induced at the collection electrode and the second (SPICE) to guarantee high precision simulation of the front-end electronics using realistic signal events. Irradiation is also modeled, both from the charge propagation side (charge trapping) and from the front-end response side (high input signal discharge). We have applied this methodology to the MAPS developed in the context of the Belle II vertex detector upgrade. In this contribution, we detail the key features of the exhaustive simulation flow, present the outcome of the comparison with the TJ-Monopix2 measurements and discuss the interest of the methodology for the development of modern MAPS.

physics.ins-det

Radiation damage study of Belle II silicon strip sensors with 90 MeV electron irradiation

The silicon strip sensors of the Belle II silicon vertex detector were irradiated with 90 MeV electron beams up to an equivalent 1-MeV-neutron fluence of $3.0\times 10^{13}~{\rm n}_{\rm eq}/{\rm cm^2}$. We measure changes in sensor properties induced by radiation damage in the semiconductor bulk. Electrons around this energy are a major source of beam-induced background during Belle II operation. We discuss observed changes in full depletion voltage, sensor leakage current, noise, and charge collection. The sensor bulk type inverts at an equivalent 1-MeV-neutron fluence of $6.0\times 10^{12}~{\rm n}_{\rm eq}/{\rm cm^2}$. The leakage current increases proportionally to the radiation dose. We determine a damage constant of $3.9 \times 10^{-17}$ A/cm at 17 C$^\circ$ immediately after irradiation, which drops significantly to approximately 40% of the initial value in 200 hours, then stabilizes to approximately 30% of the initial value in 1000 hours. We measure sensor noise and signal charge for a sensor irradiated with the equivalent 1-MeV-neutron fluence of $3.0\times 10^{13}~{\rm n}_{\rm eq}/{\rm cm^2}$. Noise increases by approximately 44% after irradiation, while signal charge does not change significantly when a sufficiently high bias voltage is applied.

physics.ins-det

Operational experience and performance of the Silicon Vertex Detector after the first long shutdown of Belle II

In 2024, the Belle II experiment resumed data taking after the Long Shutdown 1, which was required to install a two-layer pixel detector and upgrade accelerator components. We describe the challenges of this shutdown and the operational experience thereafter. With new data, the silicon-strip vertex detector (SVD) confirmed the high hit efficiency, the large signal-to-noise ratio, and the excellent cluster position resolution. In the coming years, the SuperKEKB peak luminosity is expected to increase to its target value, resulting in a larger SVD occupancy caused by beam background. Considerable efforts have been made to improve SVD reconstruction software by exploiting the excellent SVD hit-time resolution to determine the collision time and reject off-time particle hits. A novel procedure to group SVD hits event-by-event, based on their time, has been developed using the grouping information during reconstruction, significantly reducing the fake rate while preserving the tracking efficiency. The front-end chip (APV25) is operated in the multi-peak mode, which reads six samples. A 3/6-mixed acquisition mode, based on the timing precision of the trigger, reduces background occupancy, trigger dead-time, and data size. Studies of the radiation damage show that the SVD performance will not seriously degrade during the lifetime of the detector, despite moderate radiation-induced increases in sensor current and strip noise.

physics.ins-det

Silicon Vertex Detector of the Belle II Experiment

The silicon vertex detector (SVD) is installed at the heart of the Belle II experiment, taking data at the high-luminosity $B$-Factory SuperKEKB since 2019. The detector has shown a stable and above-99\% hit efficiency, with a large signal-to-noise in all sensors since the beginning of data taking. Cluster position and time resolution have been measured with 2020 and 2022 data and show excellent performance and stability. The effect of radiation damage is visible, but not affecting the performance. As the luminosity increases, higher machine backgrounds are expected and the excellent hit-time information in SVD can be exploited for background rejection. In particular, we have recently developed a novel procedure to select hits by grouping them event-by-event based on their time. This new procedure allows a significant reduction of the fake rate, while preserving the tracking efficiency, and it has therefore replaced the previous cut-based procedure. We have developed a method that uses the SVD hits to estimate the track time (previously unavailable) and the collision time. It has a similar precision to the estimate based on the drift chamber but its execution time is three orders of magnitude smaller, allowing a faster online reconstruction that is crucial in a high luminosity regime. The track time is a powerful information provided to analysis that allows, together with the above-mention grouping selection, to raise the occupancy limit above that expected at nominal luminosity, leaving room for a safety factor. Finally, in June 2022 the data taking of the Belle II experiment was stopped to install a new two-layer DEPFET detector (PXD) and upgrade components of the accelerator. The whole silicon tracker (PXD+SVD) has been extracted from Belle II, the new PXD installed, the detector closed and commissioned. We briefly describe the SVD results of this upgrade.

hep-ex

Upgrade of Belle II Vertex Detector with CMOS Pixel Technology

The Belle II experiment at KEK in Japan considers upgrading its vertex detector system to address the challenges posed by high background levels caused by the increased luminosity of the SuperKEKB collider. One proposal for upgrading the vertex detector aims to install a 5-layer all monolithic pixel vertex detector based on fully depleted CMOS sensors in 2027. The new system will use the OBELIX MAPS chips to improve background robustness and reduce occupancy levels through small and fast pixels. This causes better track finding, especially for low transverse momenta tracks. This text will focus on the predecessor of the OBELIX sensor, the TJ-Monopix2, presenting laboratory and test beam results on pixel response, efficiency, and spatial resolution.

physics.ins-det

Measured and projected beam backgrounds in the Belle II experiment at the SuperKEKB collider

The Belle II experiment at the SuperKEKB electron-positron collider aims to collect an unprecedented data set of $50~{\rm ab}^{-1}$ to study $CP$-violation in the $B$-meson system and to search for Physics beyond the Standard Model. SuperKEKB is already the world's highest-luminosity collider. In order to collect the planned data set within approximately one decade, the target is to reach a peak luminosity of $\rm 6 \times 10^{35}~cm^{-2}s^{-1}$ by further increasing the beam currents and reducing the beam size at the interaction point by squeezing the betatron function down to $\beta^{*}_{\rm y}=\rm 0.3~mm$. To ensure detector longevity and maintain good reconstruction performance, beam backgrounds must remain well controlled. We report on current background rates in Belle II and compare these against simulation. We find that a number of recent refinements have significantly improved the background simulation accuracy. Finally, we estimate the safety margins going forward. We predict that backgrounds should remain high but acceptable until a luminosity of at least $\rm 2.8 \times 10^{35}~cm^{-2}s^{-1}$ is reached for $\beta^{*}_{\rm y}=\rm 0.6~mm$. At this point, the most vulnerable Belle II detectors, the Time-of-Propagation (TOP) particle identification system and the Central Drift Chamber (CDC), have predicted background hit rates from single-beam and luminosity backgrounds that add up to approximately half of the maximum acceptable rates.

hep-ex

Measurement of the cluster position resolution of the Belle II Silicon Vertex Detector

The Silicon Vertex Detector (SVD), with its four double-sided silicon strip sensor layers, is one of the two vertex sub-detectors of Belle II operating at SuperKEKB collider (KEK, Japan). Since 2019 and the start of the data taking, the SVD has demonstrated a reliable and highly efficient operation, even running in an environment with harsh beam backgrounds that are induced by the world's highest instantaneous luminosity. In order to provide the best quality track reconstruction with an efficient pattern recognition and track fit, and to correctly propagate the uncertainty on the hit's position to the track parameters, it is crucial to precisely estimate the resolution of the cluster position measurement. Several methods for estimating the position resolution directly from the data will be discussed.

physics.ins-det

Beam background expectations for Belle II at SuperKEKB

The Belle II experiment at the SuperKEKB electron-positron collider aims to collect an unprecedented data set of $\rm 50~{\rm ab}^{-1}$ to study $CP$-violation in the $B$-meson system and to search for Physics beyond the Standard Model (BSM). SuperKEKB is already the world's highest-luminosity collider. In order to collect the planned data set within approximately one decade, the target is to reach a peak luminosity of $\rm 6.3 \times 10^{35}~cm^{-2}s^{-1}$ by further increasing the beam currents and reducing the beam-size at the interaction point by squeezing the betatron function down to $\beta^{*}_{\rm y}=\rm 0.3~mm$. Beam backgrounds are a key challenge in this context. We estimate the expected background evolution in the next ten years and discuss potential challenges and background mitigation strategies. We find that backgrounds will remain high but acceptable until a luminosity of at least $\rm 2.8\times 10^{35}~cm^{-2}s^{-1}$ is reached at $\beta^{*}_{\rm y}=\rm 0.6~mm$. Beyond this luminosity, predictions are highly uncertain, owing to a planned redesign of the interaction region. Improved background estimates with reduced uncertainties for the final, maximum-luminosity operation will require completion of this redesign.

hep-ex

The Silicon Vertex Detector of the Belle II Experiment

In 2019 the Belle II experiment started data taking at the asymmetric SuperKEKB collider (KEK, Japan) operating at the Y(4S) resonance. Belle II will search for new physics beyond the Standard Model by collecting an integrated luminosity of 50~ab$^{-1}$. The silicon vertex detector (SVD), consisting of four layers of double-sided silicon strip sensors, is one of the two vertex sub-detectors. The SVD extrapolates the tracks to the inner pixel detector (PXD) with enough precision to correctly identify hits in the PXD belonging to the track. In addition the SVD has standalone tracking capability and utilizes ionization to enhance particle identification in the low momentum region. The SVD is operating reliably and with high efficiency, despite exposure to the harsh beam background of the highest peak-luminosity collider ever built. High signal-to-noise ratio and hit efficiency have been measured, as well as the spatial resolution; all these quantities show excellent stability over time. Data-simulation agreement on cluster properties has recently been improved through a careful tuning of the simulation. The precise hit-time resolution can be exploited to reject out-of-time hits induced by beam background, which will make the SVD more robust against higher levels of background. During the first three years of running, radiation damage effects on strip noise, sensor currents and depletion voltage have been observed, as well as some coupling capacitor failure due to intense radiation bursts. None of these effects cause significant degradation in the detector performance.

physics.ins-det

Performance of the diamond-based beam-loss monitor system of Belle II

We designed, constructed and have been operating a system based on single-crystal synthetic diamond sensors, to monitor the beam losses at the interaction region of the SuperKEKB asymmetric-energy electron-positron collider. The system records the radiation dose-rates in positions close to the inner detectors of the Belle II experiment, and protects both the detector and accelerator components against destructive beam losses, by participating in the beam-abort system. It also provides complementary information for the dedicated studies of beam-related backgrounds. We describe the performance of the system during the commissioning of the accelerator and during the first physics data taking.

physics.ins-det

Quantum Computation in a radio single mode cavity: the dissipative Jaynes and Cummings Model

In this paper we have considered the interaction of a Jaynes and Cummings system with the electromagnetic field in its vacuum state and, solving the dynamical problem, we have analyzed the amount of entanglement induced in the bipartite system (atom + cavity mode) by the common electromagnetic reservoir. This has allowed us to quantitatively characterize the regime under which field-induced cooperative effects are not vanished by dissipation. Once the Decoherence Free Regime is reached, transient entanglement tends to become stationary and, therefore, usable for quantum gate implementation.

quant-ph

R&D Paths of Pixel Detectors for Vertex Tracking and Radiation Imaging

This report reviews current trends in the R&D of semiconductor pixellated sensors for vertex tracking and radiation imaging. It identifies requirements of future HEP experiments at colliders, needed technological breakthroughs and highlights the relation to radiation detection and imaging applications in other fields of science.

physics.ins-det

Obtaining Traffic Information by Urban Air Quality Inspection

The level of air quality in urban centres is affected by emission of several pollutants, mainly coming from the vehicles flowing in their road networks. This is a well known phenomenon that influences the quality of life of people. Despite the deep concern of researchers and technicians, we are far from a total understanding of this phenomenon. On the contrary, the availability of reliable forecasting models would constitute an important tool for administrators in order of assessing suitable actions concerning the transportation policies, public as well private. Referring to the situation of the running fleet and the measured pollutant concentrations concerning the Italian town of Palermo, a data-deduced traffic model is here derived, its truthfulness being justified by a fuzzyfication of the phenomenon. A first validation of the model is supplied by utilising the emissions characteristics and the pollutant concentrations referring to a two years period of time. This work could represent a first attempt in defining a new approach to the problem of the pollution of the urban contexts, in order of providing administrators with a reliable and easier tool.

physics.flu-dyn

Measurement of the Charge Collection Efficiency after Heavy Non-Uniform Irradiation in BaBar Silicon Detectors

We have investigated the depletion voltage changes, the leakage current increase and the charge collection efficiency of a silicon microstrip detector identical to those used in the inner layers of the BaBar Silicon Vertex Tracker (SVT) after heavy non-uniform irradiation. A full SVT module with the front-end electronics connected has been irradiated with a 0.9 GeV electron beam up to a peak fluence of 3.5 x 10^14 e^-/cm^2, well beyond the level causing substrate type inversion. We irradiated one of the two sensors composing the module with a non-uniform profile with sigma=1.4 mm that simulates the conditions encountered in the BaBar experiment by the modules intersecting the horizontal machine plane. The position dependence of the charge collection properties and the depletion voltage have been investigated in detail using a 1060 nm LED and an innovative measuring technique based only on the digital output of the chip.

physics.ins-det