SearcharxivSearch

arXiv subjects

G. Rogers

Publications and source records attributed to G. Rogers.

5 recordsLinked to original sources

Hydrofluoric acid-free titanium etching for rare-event searches

Rare-event search experiments require construction materials with high radiopurity to minimise background contributions. Thanks to its high mechanical strength, low density, machinability, and commercial availability in relatively radiopure forms, titanium is a suitable material for structural elements in rare-event searches. In such applications, a chemical etching stage is typically performed to remove surface contamination or to prepare the surface for further treatment. However, due to its chemical resistance, the etching of titanium conventionally requires hydrofluoric acid, posing serious health and safety concerns that are further exacerbated in deep underground laboratory settings. An alternative approach is proposed, which uses sulphuric acid. Grade 1 titanium samples were etched in 20\% and 40\% sulphuric acid solutions at 20$^\circ$C and 40$^\circ$C for up to 24\,h. The effects of etching were quantified through mass change measurements, surface roughness analysis, and scanning electron microscopy. Sulphuric acid effectively etches titanium, with up to $3.5\,\pm\,0.3$ mg/cm$^2$ of titanium removed for an unagitated solution of 40\% sulphuric acid at $40^\circ$C for 24\,h. Furthermore, sulphuric acid is shown to be effective at etching at lower concentration and temperature. The formation of a passivation layer during the etching may enable control of the total mass removed.

physics.ins-det

Titanium for rare-event searches: Hydrofluoric acid-free etching

Rare-event search experiments require construction materials with high radiopurity to minimise background contributions. Thanks to its high mechanical strength, low density, machinability, and commercial availability in relatively radio-pure forms, titanium is a suitable material for structural elements in rare event searches. To remove surface deposits on materials used, a chemical etching stage is usually performed. However, the chemical resistance of titanium means that, conventionally, such etching is done with hydrofluoric acid. Hydrofluoric acid presents serious health risks to users, and such hazards are compounded in the case of construction in deep underground laboratories. An alternative chemical etching using sulphuric acid is presented. This is demonstrated to etch titanium, removing 3.7 $\mu$m of material from the surface over the course of 20 hours. Scanning electron microscopy with back-scattered electron spectroscopy was used to study the surface and contamination of the titanium, demonstrating the removal of surface contaminants after etching. The proposed method is a potential alternative to those currently employed.

physics.ins-det

First operation of an ACHINOS-equipped Spherical Proportional Counter with individual anode read-out

The multi-anode sensor ACHINOS revolutionised the capabilities of the spherical proportional counter by enabling large-size, high-pressure, operation and TPC-like reconstruction capabilities through individual anode read-out. First measurements with an individually read out ACHINOS are performed, which enables improved calibration and response homogenisation. Experimental results demonstrating the improvement in energy resolution brought by the individual anode calibration are presented. These are complemented by detailed simulation studies on the effect of sensor design and manufacturing imperfections, and how they may be corrected both in hardware and analysis.

physics.ins-det

Sensitive radio-frequency measurements of a quantum dot by tuning to perfect impedance matching

Electrical readout of spin qubits requires fast and sensitive measurements, but these are hindered by poor impedance matching to the device. We demonstrate perfect impedance matching in a radio-frequency readout circuit, realized by incorporating voltage-tunable varactors to cancel out parasitic capacitances. In the optimized setup, a capacitance sensitivity of $1.6~\mathrm{aF}/\sqrt{\mathrm{Hz}}$ is achieved at a maximum source-drain bias of $170~μ$V root-mean-square and with bandwidth above $15~$MHz. Coulomb blockade is measured via both conductance and capacitance in a quantum dot, and the two contributions are found to be proportional, as expected from a quasistatic tunneling model. We benchmark our results against the requirements for single-shot qubit readout using quantum capacitance, a goal that has so far been elusive.

cond-mat.mes-hall

The CMS Tracker Readout Front End Driver

The Front End Driver, FED, is a 9U 400mm VME64x card designed for reading out the Compact Muon Solenoid, CMS, silicon tracker signals transmitted by the APV25 analogue pipeline Application Specific Integrated Circuits. The FED receives the signals via 96 optical fibers at a total input rate of 3.4 GB/sec. The signals are digitized and processed by applying algorithms for pedestal and common mode noise subtraction. Algorithms that search for clusters of hits are used to further reduce the input rate. Only the cluster data along with trigger information of the event are transmitted to the CMS data acquisition system using the S-LINK64 protocol at a maximum rate of 400 MB/sec. All data processing algorithms on the FED are executed in large on-board Field Programmable Gate Arrays. Results on the design, performance, testing and quality control of the FED are presented and discussed.

physics.ins-det