Searcharxiv⌕ Search

arXiv subjects

G. S. Li

Publications and source records attributed to G. S. Li.

43 records · Page 3Linked to original sources

The Water Purification System for the Daya Bay Reactor Neutrino Experiment

We describe the design, installation, and operation of a purification system that is able to provide large volumes of high purity ASTM (D1193-91) Type-I water to a high energy physics experiment. The water environment is underground in a lightly sealed system, and this provides significant challenges to maintaining high purity in the storage pools, each of which contains several thousand cubic meters. High purity is dictated by the need for large optical absorption length, which is critical for the operation of the experiment. The system is largely successful, and the water clarity criteria are met. We also include a discussion of lessons learned.

physics.ins-det↗

Independent Measurement of Theta13 via Neutron Capture on Hydrogen at Daya Bay

A new measurement of the $θ_{13}$ mixing angle has been obtained at the Daya Bay Reactor Neutrino Experiment via the detection of inverse beta decays tagged by neutron capture on hydrogen. The antineutrino events for hydrogen capture are distinct from those for gadolinium capture with largely different systematic uncertainties, allowing a determination independent of the gadolinium-capture result and an improvement on the precision of $θ_{13}$ measurement. With a 217-day antineutrino data set obtained with six antineutrino detectors and from six 2.9 GW$_{th}$ reactors, the rate deficit observed at the far hall is interpreted as $\sin^22θ_{13}=0.083\pm0.018$ in the three-flavor oscillation model. When combined with the gadolinium-capture result from Daya Bay, we obtain $\sin^22θ_{13}=0.089\pm0.008$ as the final result for the six-antineutrino-detector configuration of the Daya Bay experiment.

hep-ex↗

Spectral measurement of electron antineutrino oscillation amplitude and frequency at Daya Bay

A measurement of the energy dependence of antineutrino disappearance at the Daya Bay Reactor Neutrino Experiment is reported. Electron antineutrinos ($\overlineν_{e}$) from six $2.9$ GW$_{\rm th}$ reactors were detected with six detectors deployed in two near (effective baselines 512 m and 561 m) and one far (1579 m) underground experimental halls. Using 217 days of data, 41589 (203809 and 92912) antineutrino candidates were detected in the far hall (near halls). An improved measurement of the oscillation amplitude $\sin^{2}2θ_{13} = 0.090^{+0.008}_{-0.009} $ and the first direct measurement of the $\overlineν_{e}$ mass-squared difference $|Δm^{2}_{ee}|= (2.59_{-0.20}^{+0.19}) \times 10^{-3}\ {\rm eV}^2 $ is obtained using the observed $\overlineν_{e}$ rates and energy spectra in a three-neutrino framework. This value of $|Δm^{2}_{ee}|$ is consistent with $|Δm^{2}_{μμ}|$ measured by muon neutrino disappearance, supporting the three-flavor oscillation model.

hep-ex↗

Assembly and Installation of the Daya Bay Antineutrino Detectors

The Daya Bay reactor antineutrino experiment is designed to make a precision measurement of the neutrino mixing angle theta13, and recently made the definitive discovery of its nonzero value. It utilizes a set of eight, functionally identical antineutrino detectors to measure the reactor flux and spectrum at baselines of 300 - 2000m from the Daya Bay and Ling Ao Nuclear Power Plants. The Daya Bay antineutrino detectors were built in an above-ground facility and deployed side-by-side at three underground experimental sites near and far from the nuclear reactors. This configuration allows the experiment to make a precision measurement of reactor antineutrino disappearance over km-long baselines and reduces relative systematic uncertainties between detectors and nuclear reactors. This paper describes the assembly and installation of the Daya Bay antineutrino detectors.

physics.ins-det↗

Automated Calibration System for a High-Precision Measurement of Neutrino Mixing Angle $θ_{13}$ with the Daya Bay Antineutrino Detectors

We describe the automated calibration system for the antineutrino detectors in the Daya Bay Neutrino Experiment. This system consists of 24 identical units instrumented on 8 identical 20-ton liquid scintillator detectors. Each unit is a fully automated robotic system capable of deploying an LED and various radioactive sources into the detector along given vertical axes. Selected results from performance studies of the calibration system are reported.

physics.ins-det↗

Improved Measurement of Electron Antineutrino Disappearance at Daya Bay

We report an improved measurement of the neutrino mixing angle $θ_{13}$ from the Daya Bay Reactor Neutrino Experiment. We exclude a zero value for $\sin^22θ_{13}$ with a significance of 7.7 standard deviations. Electron antineutrinos from six reactors of 2.9 GW$_{\rm th}$ were detected in six antineutrino detectors deployed in two near (flux-weighted baselines of 470 m and 576 m) and one far (1648 m) underground experimental halls. Using 139 days of data, 28909 (205308) electron antineutrino candidates were detected at the far hall (near halls). The ratio of the observed to the expected number of antineutrinos assuming no oscillations at the far hall is $0.944\pm 0.007({\rm stat.}) \pm 0.003({\rm syst.})$. An analysis of the relative rates in six detectors finds $\sin^22θ_{13}=0.089\pm 0.010({\rm stat.})\pm0.005({\rm syst.})$ in a three-neutrino framework.

hep-ex↗

A side-by-side comparison of Daya Bay antineutrino detectors

The Daya Bay Reactor Neutrino Experiment is designed to determine precisely the neutrino mixing angle $θ_{13}$ with a sensitivity better than 0.01 in the parameter sin$^22θ_{13}$ at the 90% confidence level. To achieve this goal, the collaboration will build eight functionally identical antineutrino detectors. The first two detectors have been constructed, installed and commissioned in Experimental Hall 1, with steady data-taking beginning September 23, 2011. A comparison of the data collected over the subsequent three months indicates that the detectors are functionally identical, and that detector-related systematic uncertainties exceed requirements.

physics.ins-det↗