SearcharxivSearch

arXiv subjects

G. Schepers

Publications and source records attributed to G. Schepers.

At least 19 recordsLinked to original sources

The PANDA Barrel DIRC: From design to assembly

The Barrel DIRC counter will serve as the primary particle identification detector in the PANDA experiment, enabling high-precision hadron physics studies through antiproton-proton annihilations across a momentum range of 1.5 GeV/c to 15 GeV/c. It is designed to distinguish charged pions from kaons with a separation of at least 3 standard deviations up to 3.5 GeV/c within polar angles of 22 degrees to 140 degrees. A lens focusing is used the first time in a DIRC detector. After a successful evaluation in particle beams, the key components, i.e. radiator bars and photon sensors, were purchased and tested.

physics.ins-det

The PANDA Barrel DIRC

The PANDA experiment at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR), Darmstadt, Germany, will address fundamental questions of hadron physics using $\bar{p}p$ annihilations. Excellent Particle Identification (PID) over a large range of solid angles and particle momenta will be essential to meet the objectives of the rich physics program. Charged PID in the target region will be provided by a Barrel DIRC (Detection of Internally Reflected Cherenkov light) counter. The Barrel DIRC, covering the polar angle range of 22-140 degrees, will provide a $\pi/K$ separation power of at least 3 standard deviations for charged particle momenta up to 3.5 GeV/c. The design of the Barrel DIRC features narrow radiator bars made from synthetic fused silica, an innovative multi-layer spherical lens focusing system, a prism-shaped synthetic fused silica expansion volume, and an array of lifetime-enhanced Microchannel Plate PMTs (MCP-PMTs) to detect the hit location and arrival time of the Cherenkov photons. Detailed Monte-Carlo simulations were performed, and reconstruction methods were developed to study the performance of the system. All critical aspects of the design and the performance were validated with system prototypes in a mixed hadron beam at the CERN PS. In 2020 the PANDA Barrel DIRC project advanced from the design stage to component fabrication. The series production of the fused silica bars was successfully completed in 2021 and delivery of the MCP-PMTs started in May 2022.

hep-ex

Lifetime and performance of the very latest microchannel-plate photomultipliers

The PANDA experiment at the FAIR facility at GSI will study hadron physics using a high intensity antiproton beam of up to 15 GeV/c momentum to perform high precision spectroscopy. Two DIRC detectors with their image planes residing in an $\sim$1 T magnetic field will be used in the experiment. The only suitable photon detectors for both DIRCs were identified to be Microchannel-Plate Photomultipliers (MCP-PMTs). Since the aging problems of MCP-PMTs were solved recently by coating the MCPs with the so-called ALD-technique (atomic layer deposition) we are investigating devices which are significantly improved with respect to other parameters, as, e.g., the collection efficiency (CE) and the quantum efficiency (QE). The latest generation of MCP-PMTs can reach a detective quantum efficiency DQE = QE - CE of 30%. This paper will present the performance of the most advanced 53 $\times$ 53 mm$^2$ ALD-coated MCP-PMTs from Photonis (8 $\times$ 8 and 3 $\times$ 100 anodes) and Photek (8 $\times$ 8 anodes), also inside the magnetic field. With a picosecond laser and a multi-hit capable DAQ system which allows read out up to 300 pixels simultaneously, parameters like darkcount rate, afterpulse probability and time resolution can be investigated as a function of incident photon position.

physics.ins-det

Performance of the most recent Microchannel-Plate PMTs for the PANDA DIRC detectors at FAIR

In the PANDA experiment at the FAIR facility at GSI two DIRC (Detection of Internally Reflected Cherenkov light) detectors will be used for $\pi$/K separation up to 4 GeV/c. Due to their location in a high magnetic field and other stringent requirements like high detection efficiency, low dark count rate, radiation hardness, long lifetime and good timing, MCP-PMTs (microchannel-plate photomultiplier) were the best choice of photon sensors for the DIRC detectors in the PANDA experiment. This paper will present the performance of some of the latest 2$\times$2 inch$^2$ MCP-PMTs from Photek and Photonis, including the first mass production tubes for the PANDA Barrel DIRC from Photonis. Performance parameters like the collection efficiency (CE), quantum efficiency (QE), and gain homogeneity were determined. The effect of magnetic fields on some properties like gain and charge cloud width was investigated as well. Apart from that the spatial distribution of many internal parameters like time resolution, dark count rate, afterpulse ratio, charge sharing crosstalk and recoil electrons were measured simultaneously with a multihit capable DAQ system. The latest generation of Photonis MCP-PMTs shows an unexpected "escalation" effect where the MCP-PMT itself produces photons.

physics.ins-det

The PANDA DIRCs

The PANDA experiment at the FAIR facility adresses open questions in hadron physics with antiproton beams in the momentum range of 1.5-15 GeV/c. The antiprotons are stored and cooled in a High Energy Storage RING (HESR) with a momentum spread down to Dp/p = 4*10^-5. A high luminosity of up to 2*10^32 cm-2 s-1 can be achieved. An excellent hadronic particle identification (PID) will be provided by two Cherenkov detectors using the priciple of Detection of Internally Reflected Cherenkov light (DIRC). In the forward direction from polar angles of 5 degree to 22 degree, the Endcap Disc DIRC (EDD) separates pions from kaons up to momenta of 4 GeV/c. Between 22 degree and 140 degree the Barrel DIRC cleanly separates pions from kaons for momenta up to 3.5 GeV/c. This article describes the design of the Barrel DIRC and of the Endcap Disc DIRC and the validation of their designs in particle beams at the CERN PS.

physics.ins-det

Time imaging reconstruction for the PANDA Barrel DIRC

The innovative Barrel DIRC (Detection of Internally Reflected Cherenkov light) counter will provide hadronic particle identification (PID) in the central region of the PANDA experiment at the new Facility for Antiproton and Ion Research (FAIR), Darmstadt, Germany. This detector is designed to separate charged pions and kaons with at least 3 standard deviations for momenta up to 3.5 GeV/c, covering the polar angle range of 22$^{\circ}$-140$^{\circ}$. An array of microchannel plate photomultiplier tubes is used to detect the location and arrival time of the Cherenkov photons with a position resolution of 2 mm and time precision of about 100 ps. The time imaging reconstruction has been developed to make optimum use of the observables and to determine the performance of the detector. This reconstruction algorithm performs particle identification by directly calculating the maximum likelihoods using probability density functions based on detected photon propagation time in each pixel, determined directly from the data, or analytically, or from detailed simulations.

physics.ins-det

Status of the PANDA Barrel DIRC

The PANDA experiment will use cooled antiproton beams with high intensity stored1 in the High Energy Storage Ring at FAIR. Reactions on a fixed target producing charmed hadrons will shed light on the strong QCD. Three ring imaging Cherenkov counters are used for charged particle identification. The status of the Barrel DIRC (Detection of Internally Reflected Cherenkov light) is described. Its design is robust and its performance validated in experiments with test beams. The PANDA Barrel DIRC has entered the construction phase and will be installed in 2023/2024.

physics.ins-det

Particle Identification with DIRCs at PANDA

The DIRC technology (Detection of Internally Reflected Cherenkov light) offers an excellent possibility to minimize the form factor of Cherenkov detectors in hermetic high energy detectors. The PANDA experiment at FAIR in Germany will combine a barrel-shaped DIRC with a disc-shaped DIRC to cover an angular range of 5 to 140 degrees. Particle identification for pions and kaons with a separation power of 3 standard deviations or more will be provided for momenta between 0.5 GeV/c and 3.5 GeV/c in the barrel region and up to 4 GeV/c in the forward region. Even though the concept is simple, the design and construction of a DIRC is challenging. High precision optics and mechanics are required to maintain the angular information of the Cherenkov photons during multiple internal reflections and to focus the individual photons onto position sensitive photon detectors. These sensors must combine high efficiencies for single photons with low dark count rates and good timing resolution at high rates. The choice of radiation hard fused silica for the optical material and of MCP-PMT photon sensors is essential for DIRC detectors to survive in an environment of radiation and strong magnetic field. The two DIRC detectors differ in the focusing optics, in the treatment of chromatic dispersion and in the electronic readout systems. The technical design of the two DIRC detectors and their validation by testing prototypes in a mixed particle beam at CERN are presented.

physics.ins-det

The Innovative Design of the Endcap Disc DIRC Detector for PANDA at FAIR

The key component of the future PANDA experiment at FAIR is a fixed-target detector for collisions of antiprotons with a proton target up to a beam momentum of 15 GeV/c and is designed to address a large number of open questions in the hadron physics sector. In order to guarantee an excellent PID for charged hadrons in the polar angle range between $5^\circ$ and $22^\circ$, a new type of Cherenkov detector called Endcap Disc DIRC (EDD) has been developed for the forward endcap of the PANDA target spectrometer. The desired separation power of at least 3 s.d. for the separation of $\pi^\pm$ and $K^\pm$ up to particle momenta of 4 GeV/c was determined with simulation studies and validated during various testbeam campaigns at CERN and DESY.

physics.ins-det

The Innovative Design of the PANDA Barrel DIRC

The Barrel DIRC of the PANDA experiment at FAIR will cleanly separate pions from kaons for the physics program of PANDA. Innovative solutions for key components of the detector sitting in the strong magnetic field of the compact PANDA target spectrometer as well as two reconstruction methods were developed in an extensive prototype program. The technical design and present results from the test beam campaigns at the CERN PS in 2017 and 2018 are discussed.

physics.ins-det

The Barrel DIRC detector of PANDA

The PANDA experiment is one of the four large experiments being built at FAIR in Darmstadt. It will use a cooled antiproton beam on a fixed target within the momentum range of 1.5 to 15 GeV/c to address questions of strong QCD, where the coupling constant $\alpha_s \gtrsim 0.3$. The luminosity of up to $2 \cdot 10^{32} cm^{-2}s^{-1}$ and the momentum resolution of the antiproton beam down to \mbox{$\Delta$p/p = 4$\cdot10^{-5}$} allows for high precision spectroscopy, especially for rare reaction processes. Above the production threshold for open charm mesons the production of kaons plays an important role for identifying the reaction. The DIRC principle allows for a compact particle identification for charged particles in a hermetic detector, limited in size by the electromagnetic lead tungstate calorimeter. The Barrel DIRC in the target spectrometer covers polar angles between $22^\circ$ and $140^\circ$ and will achieve a pion-kaon separation of 3 standard deviations up to 3.5 GeV/$c$. Here, results of a test beam are shown for a single radiator bar coupled to a prism with $33^\circ$ opening angle, both made from synthetic fused silica read out with a photon detector array with 768 pixels.

physics.ins-det

The PANDA DIRC Detectors at FAIR

The PANDA detector at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR) addresses fundamental questions of hadron physics. An excellent hadronic particle identification (PID) will be accomplished by two DIRC (Detection of Internally Reflected Cherenkov light) counters in the target spectrometer. The design for the barrel region covering polar angles between 22 deg. to 140 deg. is based on the successful BABAR DIRC with several key improvements, such as fast photon timing and a compact imaging region. The novel Endcap Disc DIRC will cover the smaller forward angles between 5 deg. (10 deg.) to 22 deg. in the vertical (horizontal) direction. Both DIRC counters will use lifetime-enhanced microchannel plate PMTs for photon detection in combination with fast readout electronics. Geant4 simulations and tests with several prototypes at various beam facilities have been used to evaluate the designs and validate the expected PID performance of both PANDA DIRC counters.

physics.ins-det

Technical Design Report for the: PANDA Straw Tube Tracker

This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory and the measurement of the specific energy-loss for a particle identification. Dedicated simulations with full analysis studies of certain proton-antiproton reactions, identified as being benchmark tests for the whole PANDA scientific program, have been performed to test the STT layout and performance. The results are presented, and the time lines to construct the STT are described.

physics.ins-det

Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets

This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.

physics.ins-det

Physics Performance Report for PANDA: Strong Interaction Studies with Antiprotons

To study fundamental questions of hadron and nuclear physics in interactions of antiprotons with nucleons and nuclei, the universal PANDA detector will be built. Gluonic excitations, the physics of strange and charm quarks and nucleon structure studies will be performed with unprecedented accuracy thereby allowing high-precision tests of the strong interaction. The proposed PANDA detector is a state-of-the art internal target detector at the HESR at FAIR allowing the detection and identification of neutral and charged particles generated within the relevant angular and energy range. This report presents a summary of the physics accessible at PANDA and what performance can be expected.

hep-ex

Technical Design Report for PANDA Electromagnetic Calorimeter (EMC)

This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and radiation hardness studies. The document shows that the EMC is ready for construction up to the front-end electronics interface.

physics.ins-det

Drift chamber with a c-shaped frame

We present the construction of a planar drift chamber with wires stretched between two arms of a c-shaped aluminium frame. The special shape of the frame allows to extendthe momentum acceptance of the COSY-11 detection system towards lower momenta without suppressing the high momentum particles. The proposed design allows for construction of tracking detectors covering small angles with respect to the beam, which can be installed and removed without dismounting the beam-pipe. For a three-dimensional track reconstruction a computer code was developed using a simple algorithm of hit preselection.

nucl-ex

Energy dependence of the Lambda/Sigma0 production cross section ratio in proton proton interactions

The production of the Lambda and Sigma0 hyperons has been measured via the pp->pK+Lambda / Sigma0 reaction at the internal COSY-11 facility in the excess energy range between 14 and 60 MeV. The transition of the Lambda/Sigma0 cross section ratio from about 28 at Q<=13 MeV to the high energy level of about 2.5 is covered by the data showing a strong decrease of the ratio between 10 and 20 MeV excess energy. Effects from the final state interactions in the p-Sigma0 channel seem to be much smaller compared to the p-Lambda one. Estimates of the effective range parameters are given for the N-Lambda and the N-Sigma systems.

nucl-ex