SearcharxivSearch

arXiv subjects

G. Serianni

Publications and source records attributed to G. Serianni.

At least 19 recordsLinked to original sources

Negative ion density in the ion source SPIDER in Cs free conditions

The SPIDER experiment, operated at the Neutral Beam Test Facility of Consorzio RFX, Padua, hosts the prototype of the H-/D- ion source for the ITER neutral beam injectors. The maximization of the ion current extracted from the source and the minimization of the amount of co-extracted electrons are among the most relevant targets to accomplish. The Cavity Ring-Down Spectroscopy diagnostic measures the negative ion density in the source close to the plasma grid (the plasma-facing grid of the ion acceleration system), so to identify the source operational parameters that maximize the amount of negative ions which can be extracted. In this study SPIDER was operated in hydrogen and deuterium in Cs-free conditions, therefore negative ions were mostly produced by reactions in the plasma volume. This work shows how the magnetic filter field and the bias currents, present in SPIDER to limit the amount of co-extracted electrons, affect the density of negative ions available for extraction. The results indicate that the magnetic filter field in front of the acceleration system should be set between about 1.6 mT, condition that maximizes the density of available negative ions, and about 3.2 mT, condition that minimizes the ratio of electron current to ion current. The negative ion density also resulted to be maximized when the plasma grid and its surrounding bias plate was positively biased against the source body with a total current in the range 0 A÷100 A. The paper shows also how much, in Cs-free conditions, the electric fields in the acceleration system can affect the density of negative ions in the source, close to the plasma grid apertures.

physics.plasm-ph

Characterization of Cs-free negative ion production in the ion source SPIDER by Cavity Ring-Down Spectroscopy

The Neutral beam Injectors of the ITER experiment will be based on negative ion sources for the generation of beams composed by 1 MeV H/D particles. The prototype of these sources is currently under testing in the SPIDER experiment, part of the Neutral Beam Test Facility of Consorzio RFX, Padua, Italy. Among the targets of the experimentation in SPIDER, it is of foremost importance to maximize the beam current density extracted from the source acceleration system. The SPIDER operating conditions can be optimized thanks to a Cavity Ring-down Spectroscopy diagnostic, which is able to give line-integrated measurements of negative ion density in proximity of the acceleration system apertures. Regarding the diagnostic technique, this work presents a phenomenon of drift in ring down time measurements, which develops in a time scale of few hours. This issue may significantly affect negative ion density measurements for plasma pulses of 1 h duration, as required by ITER. Causes and solutions are discussed. Regarding the source performance, this paper presents how negative ion density is influenced by the RF power used to sustain the plasma, and by the magnetic filter field present in SPIDER to limit the amount of co-extracted electrons. In this study, SPIDER was operated in hydrogen and deuterium, in Cs-free conditions.

physics.plasm-ph

Characterization of cesium and H-/D- density in the negative ion source SPIDER

The Heating Neutral Beam Injectors (HNBs) for ITER will have to deliver 16.7 MW beams of H/D particles at 1 MeV energy. The beams will be produced from H-/D- ions, generated by a radiofrequency plasma source coupled to an ion acceleration system. A prototype of the ITER HNB ion source is being tested in the SPIDER experiment, part of the ITER Neutral Beam Test Facility at Consorzio RFX. Reaching the design targets for beam current density and fraction of coextracted electrons is only possible by evaporating cesium in the source, in particular on the plasma facing grid (PG) of the acceleration system. In this way the work function of the surfaces decreases, significantly increasing the amount of surface reactions that convert neutrals and positive ions into H-/D-. It is then of paramount importance to monitor the density of negative ions and the density of Cs in the proximity of the PG. Monitoring the Cs spatial distribution along the PG is also essential to guarantee the uniformity of the beam current. In SPIDER, this is possible thanks to the Cavity Ringdown Spectroscopy (CRDS) and the Laser absorption Spectroscopy diagnostics (LAS), which provide line-integrated measurements of negative ion density and neutral, ground state Cs density, respectively. The paper discusses the CRDS and LAS measurements as a function of input power and of the magnetic and electric fields used to reduce the coextraction of electrons. Negative ion density data are in qualitative agreement with the analogous measurements in Cs-free conditions. In agreement with simulations, Cs density is peaked in the center of the source; a top/bottom non uniformity is also present. Several effects of plasma on Cs deposition and negative ion production are presented.

physics.plasm-ph

Direct current measurements of the SPIDER beam: a comparison to existing beam diagnostics

For negative ion beam sources there are several methods of measuring the accelerated beam current, most commonly electrical measurements at the power supply and calorimetric measurements. On SPIDER, the ITER Heating Neutral Beam full-scale beam source prototype, electrical measurements at the acceleration grid power supply (AGPS) are complemented by polarizing the diagnostic calorimeter STRIKE to provide an additional electrical measurement of the accelerated current. This is in addition to the calorimetric measurements provided by STRIKE. These diagnostics give differing measurements of the beam current. Exploiting the reduced number of open apertures on SPIDER a new beam diagnostic has been installed to measure the individual beamlet currents directly. The so called Beamlet Current Monitor (BCM) has been used to measure the current of five beamlets during the most recent SPIDER campaign. This work compares the BCM current to the electrical measurements at the AGPS and STRIKE. The average BCM current agrees well with the STRIKE electrical measurements, indicating that the AGPS overestimates the beam current. The individual beamlets are compared to the STRIKE calorimetric measurements, showing similar current trends with the source parameters.

physics.acc-ph

2D electromagnetic simulations of RF heating via inductive coupling in the SPIDER device

SPIDER is the prototype ion source of MITICA, the full-size neutral beam heating system conceived for the ITER tokamak. It includes eight drivers to heat and sustain the inductively coupled plasma (ICP). Owing to their near cylindrical symmetry, the coupling between the radio-frequency (RF) active currents and the source plasma is studied using a 2D electromagnetic approach with simplified expressions for the plasma electrical conductivity taken from the literature. The power absorbed by the plasma and the effect of the induced plasma currents in lowering the inductance of the driver are based on data from the dedicated S16 experimental campaign (y.~2020) of SPIDER: plasma electron densities on the order of $10^{18}$ m$^{-3}$, electron temperatures $\sim 10$ eV; neutral gas pressure $\sim 0.3$ Pa and up to $50$ kW of net power per driver. It is found that the plasma conductivity cannot be explained by the friction forces associated to local collisional processes alone. The inclusion of an effective collisionality associated to non-local processes seems also insufficient to explain the experimental information. Only when the electrical conductivity is reduced where the RF magnetic field is more intense, can the heating power and driver inductance be acceptably reproduced. We present the first 2D electromagnetic ICP calculations in SPIDER for two types of plasma, without and with the addition of a static magnetic field. The power transfer efficiency to the plasma of the first drivers of SPIDER, in view of these models, is around 50%

physics.plasm-ph

Spider Ion Source and Extraction Power Supplies -- An update of the design after four years of operation

SPIDER, the ion source prototype for ITER neutral beam injectors, has been in operation since 2018. The experiment includes a system of Ion Source and Extraction Power Supplies (ISEPS), whose design dates back to 2011. Since then the experience gained has led to substantial changes, the most dramatic modification being the complete replacement of the radiofrequency power supply, described elsewhere. This contribution details operating experience and calculations that have led to defining new requirements for a specific subset of power supplies, the bias power supplies. The bias power supplies perform the function of filtering out electrons extracted together with the negative ions and in the original 2011 ISEPS design are single quadrant resonant converters. For the two bias power supplies, the picture resulting from the review described in the paper is a substantial redesign, with the ability to operate in four quadrants and a twofold increase of the rated output voltage the most significant new specifications.

physics.plasm-ph

First results from beam emission spectroscopy in SPIDER negative ion source

The SPIDER experiment, part of the Neutral Beam Test Facility (NBTF) at Consorzio RFX (Padua, Italy), is the prototype of the negative ion source for the ITER neutral beam injectors; the source is coupled to a 100 kV three-grid acceleration system. A Beam Emission Spectroscopy (BES) diagnostic was installed in SPIDER to study and optimize energy distribution, aiming, uniformity and divergence of the H-/D- beam extracted from the source. The diagnostic is based on the analysis of the Doppler shifted Hα/Dα light emitted in the interaction between the beam particles and the H2/D2 molecules of the background. In 2019 the BES diagnostic in SPIDER was installed and calibrated, and it allowed to characterize the first hydrogen beams extracted from the SPIDER source, in cesium free conditions. The number of active beamlets composing the beam was reduced from 1280 to 80, affecting the BES diagnostic capabilities. This paper presents the BES diagnostic setup and discusses the first collected results. Under limited extracted current density ($\sim$ 10 A/m^2) and ion energy ($\leq$35 keV), no significant vertical beam deflection caused by the magnetic filter field in the source was detected. In some cases the beamlets were observed to be elongated in horizontal direction; beamlet divergence values down to 20 mrad and 30 mrad e-folding were measured in vertical and horizontal direction, respectively; the intensity of the Doppler shifted radiation was found to be strongly correlated to the beam current and to the beam divergence. The progressive compensation of beamlet deflections (caused by electron suppression filter fields) with increasing voltage in the extraction gap was studied.

physics.plasm-ph

Lessons learned after three years of SPIDER operation and the first MITICA integrated tests

ITER envisages the use of two heating neutral beam injectors plus an optional one as part of the auxiliary heating and current drive system. The 16.5 MW expected neutral beam power per injector is several notches higher than worldwide existing facilities. A Neutral Beam Test Facility (NBTF) was established at Consorzio RFX, exploiting the synergy of two test beds, SPIDER and MITICA. SPIDER is dedicated to developing and characterizing large efficient negative ion sources at relevant parameters in ITER-like conditions: source and accelerator located in the same vacuum where the beam propagates, immunity to electromagnetic interferences of multiple radio-frequency (RF) antennas, avoidance of RF-induced discharges on the outside of the source. Three years of experiments on SPIDER have addressed to the necessary design modifications to enable full performances. The source is presently under a long shut-down phase to incorporate learnings from the experimental campaign. Parallelly, developments on MITICA, the full-scale prototype of the ITER NBI featuring a 1 MV accelerator and ion neutralization, are underway including manufacturing of in-vessel components, while power supplies and auxiliary plants are already under final testing and commissioning. Integration, commissioning and tests of the 1MV power supplies are essential for this first-of-kind system, unparalleled both in research and industry field. The integrated test to confirm 1MV output by combining invertor systems, DC generators and transmission lines extracted errors/accidents in some components. To realize a concrete system for ITER, solutions for the repair and the improvement of the system were developed. Hence, NBTF is emerging as a necessary facility, due to the large gap with existing injectors, effectively dedicated to identify issues and find solutions to enable successful ITER NBI operations in a time bound fashion.

physics.plasm-ph

Numerical and experimental investigations of a microwave interferometer for the negative ion source SPIDER

The electron density close to the extraction grids and the co-extracted electrons represent a crucial issue when operating negative ion sources for fusion reactors. An excessive electron density in the plasma expansion region can indeed inhibit the negative ion production and introduce potentially harmful electrons in the accelerator. Among the set of plasma and beam diagnostics proposed for SPIDER upgrade, a heterodyne microwave (mw) interferometer at 100 GHz is being explored as a possibility to measure electron density in the plasma extraction region. The major issue in applying this technique in SPIDER is the poor accessibility of the probing microwave beam through the source metal walls and the long distance of 4 m at which mw modules should be located outside the vacuum vessel. Numerical investigations in a full-scale geometry showed that the power transmitted through the plasma source apertures was sufficient for the microwave module sensitivity. An experimental proof-of-principle of the setup was then performed. The microwave system was tested on an experimental full-scale test-bench mimicking SPIDER viewports accessibility constraints, including the presence of a SPIDER-like plasma. The outcome of first tests revealed that, despite the geometrical constraints, in certain conditions, the electron density measurements are possible. The main issue arises from decoupling the one-pass signal from spurious multipaths generated by mw beam reflections, requiring signal cross correlation analysis. These preliminary tests demonstrate that despite the 4 m distance between the mw modules and the presence of metal walls, plasma density measurement is possible when the 80-mm diameter ports are available. In this contribution, we discuss the numerical simulations, the preliminary experimental tests and suggest design upgrades of the interferometric setup to enhance signal transmission.

physics.plasm-ph

Development and first operation of a Cavity Ring Down Spectroscopy diagnostic in the negative ion source SPIDER

The Neutral Beam Injectors of the ITER experiment will rely on negative ion sources to produce 16.7 MW beams of H/D particles accelerated at 1 MeV. The prototype of these sources was built and is currently operated in the SPIDER experiment (Source for the Production of Ions o Deuterium Extracted from an RF plasma), part of the Neutral Beam Test Facility of Consorzio RFX, Padua. In SPIDER, the H-/D- ion source is coupled to a three grids 100 kV acceleration system. One of the main targets of the experimentation in SPIDER is to uniformly maximize the extracted current density; to achieve this it is important to study the density of negative ions available in proximity of the ion acceleration system. In SPIDER, line-integrated measurements of negative ion density are performed by a Cavity Ring Down Spectroscopy (CRDS) diagnostic. Its principle of operation is based on the absorption of the photons of a laser beam pulse by H-/D- photo-detachment; the absorption detection is enhanced by trapping the laser pulse in an optical cavity, containing the absorbing medium (i.e. negative ions). The paper presents and discusses the CRDS diagnostic setup in SPIDER, including the first measurements of negative ion density, correlated to the main source parameters.

physics.plasm-ph

Electron Density and Temperature in NIO1 RF Source Operated in Oxygen and Argon

The NIO1 experiment, built and operated at Consorzio RFX, hosts an RF negative ion source, from which it is possible to produce a beam of maximum 130 mA in H- ions, accelerated up to 60 kV. For the preliminary tests of the extraction system the source has been operated in oxygen, whose high electronegativity allows to reach useful levels of extracted beam current. The efficiency of negative ions extraction is strongly influenced by the electron density and temperature close to the Plasma Grid, i.e. the grid of the acceleration system which faces the source. To support the tests, these parameters have been measured by means of the Optical Emission Spectroscopy diagnostic. This technique has involved the use of an oxygen-argon mixture to produce the plasma in the source. The intensities of specific Ar I and Ar II lines have been measured along lines of sight close to the Plasma Grid, and have been interpreted with the ADAS package to get the desired information. This work will describe the diagnostic hardware, the analysis method and the measured values of electron density and temperature, as function of the main source parameters (RF power, pressure, bias voltage and magnetic filter field). The main results show that not only electron density but also electron temperature increase with RF power; both decrease with increasing magnetic filter field. Variations of source pressure and plasma grid bias voltage appear to affect only electron temperature and electron density, respectively.

physics.plasm-ph

First Beam Characterization by Means of Emission Spectroscopy in the NIO1 Experiment

The NIO1 experiment hosts a flexible RF H- ion source, developed by INFN-LNL and Consorzio RFX to improve the present concepts for the production and acceleration of negative ions. The source is also used to benchmark the instrumentation dedicated to the ITER neutral beam test facility. Many diagnostics are installed in NIO1 to characterize the source and the extracted negative ion beam. Among them, Beam Emission Spectroscopy (BES) has been used in NIO1 to measure the divergence and the uniformity of the beam, together with the fraction of beam ions which was neutralized inside the acceleration system. The diagnostic method is based on the analysis of the Doppler shifted $H_α$ photons emitted by the fast beam particles and collected along a line of sight. The article presents the experimental setup and the analysis algorithms of the BES diagnostic, together with a discussion of the first measurements and of their correlation with the operational parameters.

physics.plasm-ph

First hydrogen operation of NIO1: characterization of the source plasma by means of an optical emission spectroscopy diagnostic

NIO1 is a compact and flexible radiofrequency H- ion source, developed by Consorzio RFX and INFN-LNL. Aim of the experimentation on NIO1 is the optimization of both the production of negative ions and their extraction and beam optics. In the initial phase of its commissioning, NIO1 was operated with nitrogen, but now the source is regularly operated also with hydrogen. To evaluate the source performances an optical emission spectroscopy diagnostic was installed. The system includes a low resolution spectrometer in the spectral range of 300-850 nm and a high resolution (50 pm) one, to study respectively the atomic and the molecular emissions in the visible range. The spectroscopic data have been interpreted also by means of a collisional-radiative model developed at IPP Garching. Besides the diagnostic hardware and the data analysis methods, the paper presents the first plasma measurements across a transition to the full H mode, in a hydrogen discharge. The characteristic signatures of this transition in the plasma parameters are described, in particular the sudden increase of the light emitted from the plasma above a certain power threshold.

physics.plasm-ph

Spatiotemporal synchronization of drift waves in a magnetron sputtering plasma

A feedforward scheme is applied for drift waves control in a magnetized magnetron sputtering plasma. A system of driven electrodes collecting electron current in a limited region of the explored plasma is used to interact with unstable drift waves. Drift waves actually appear as electrostatic modes characterized by discrete wavelengths of the order of few centimeters and frequencies of about 100 kHz. The effect of external quasi-periodic, both in time and space, travelling perturbations is studied. Particular emphasis is given to the role played by the phase relation between the natural and the imposed fluctuations. It is observed that it is possible by means of localized electrodes, collecting currents which are negligible with respect to those flowing in the plasma, to transfer energy to one single mode and to reduce that associated to the others. Due to the weakness of the external action, only partial control has been achieved.

physics.plasm-ph

Resistive g-modes in a reversed field pinch plasma

First direct experimental evidence of high frequency, high toroidal mode number (n>20), magnetic fluctuations due to unstable resistive interchange modes (g-modes) resonant in the edge region of a reversed field pinch (RFP) plasma is presented. Experimental characterization of time and space periodicities of the modes is provided by means of highly resolved in-vessel edge and insertable magnetic diagnostics. It is found that the spectral mode properties are in good agreement with the predictions of the theoretical linear resistive magnetohydrodynamic stability analysis. A simple model is proposed for the observed saturation levels of the modes.

physics.plasm-ph

Drift-Alfven vortex structures in the edge region of a fusion relevant plasma

Edge turbulent structures are commonly observed in fusion devices and are generally believed to be responsible for confinement degradation. Among their origin Drift-Alfven turbulence is one of the most commonly suggested. Drift-Alfven paradigm allows the existence of localized vortex-like structures observed also in various systems. Here we present the evidence of the presence of drift-Alfvén vortices in the edge region of RFX-Mod RFP device, showing how these structures are responsible for electromagnetic turbulence at the edge and its intermittent nature.

physics.plasm-ph

About the parabolic relation existing between the skewness and the kurtosis in time series of experimental data

In this work we investigate the origin of the parabolic relation between skewness and kurtosis often encountered in the analysis of experimental time-series. We argue that the numerical values of the coefficients of the curve may provide informations about the specific physics of the system studied, whereas the analytical curve per se is a fairly general consequence of a few constraints expected to hold for most systems.

physics.data-an

On the statistics of edge fluctuations: comparative study between various fusion devices

In this paper we present a statistical study of edge fluctuations taken with the Gas Puffing Imaging (GPI) diagnostics. We carry out a comparison of GPI signal from an extensive database including four devices (two Tokamaks and two Reversed Field Pinches). The data are analyzed in terms of their statistical moments Skewness and Kurtosis, as done in [B. Labit, et al, Phys. Rev. Lett. \textbf{98}, 255002 (2007)]. The data align along parabolic curves, although different from machine to machine, with some spread around the best-fitting curve. A discussion about the meaning of the parabolic trend as well as the departure of real data from it is provided. A phenomenological model is finally provided, attempting to accomodate experimental evidence.

physics.plasm-ph