SearcharxivSearch

arXiv subjects

G. Takahashi

Publications and source records attributed to G. Takahashi.

3 recordsLinked to original sources

A new search for the $K_{L} \to π^0 ν\overlineν$ and $K_{L} \to π^{0} X^{0}$ decays

We searched for the $CP$-violating rare decay of neutral kaon, $K_{L} \to π^0 ν\overlineν$, in data from the first 100 hours of physics running in 2013 of the J-PARC KOTO experiment. One candidate event was observed while $0.34\pm0.16$ background events were expected. We set an upper limit of $5.1\times10^{-8}$ for the branching fraction at the 90\% confidence level (C.L.). An upper limit of $3.7\times10^{-8}$ at the 90\% C.L. for the $K_{L} \to π^{0} X^{0}$decay was also set for the first time, where $X^{0}$ is an invisible particle with a mass of 135 MeV/$c^{2}$.

hep-ex

Long-lived neutral-kaon flux measurement for the KOTO experiment

The KOTO ($K^0$ at Tokai) experiment aims to observe the CP-violating rare decay $K_L \rightarrow π^0 ν\barν$ by using a long-lived neutral-kaon beam produced by the 30 GeV proton beam at the Japan Proton Accelerator Research Complex. The $K_L$ flux is an essential parameter for the measurement of the branching fraction. Three $K_L$ neutral decay modes, $K_L \rightarrow 3π^0$, $K_L \rightarrow 2π^0$, and $K_L \rightarrow 2γ$ were used to measure the $K_L$ flux in the beam line in the 2013 KOTO engineering run. A Monte Carlo simulation was used to estimate the detector acceptance for these decays. Agreement was found between the simulation model and the experimental data, and the remaining systematic uncertainty was estimated at the 1.4\% level. The $K_L$ flux was measured as $(4.183 \pm 0.017_{\mathrm{stat.}} \pm 0.059_{\mathrm{sys.}}) \times 10^7$ $K_L$ per $2\times 10^{14}$ protons on a 66-mm-long Au target.

physics.ins-det

A new method to correct deformations in emulsion using a precise photomask

A new method to correct the emulsion deformation, mainly produced in the development process, is developed to recover the high accuracy of nuclear emulsion as a tracking device. The method is based on a precise photomask and a careful treatment of the emulsion films. A position measurement accuracy of 0.6 μm is obtained over an area of 5 cm x 7 cm. The method allows to measure positions of track segments with submicron accuracy in an ECC brick with as few as 10 reference tracks for alignment. Such a performance can be important for hybrid emulsion experiments at underground laboratories where only a small number of reference tracks for alignment are available.

physics.ins-det