Fast and Efficient Detection of 511 keV Photons using Cherenkov Light in PbF$_2$ Crystal coupled to a MCP-PMT and SAMPIC Digitization Module

We study the possibility to use the Cherenkov light for the efficient detection of 511 keV photons with the goal to use it in TOF-PET. We designed and tested two detection modules consisting of PbF$_2$ crystals attached to Planacon MCP-PMT XP85012. Amplified PMT signals are digitized by the SAMPIC module with high readout rate, up to $10^5$ events/s, and a negligible contribution to the time resolution, below 20 ps (FWHM). We developed a fast 2D scanning system to calibrate the PMT time response and studied in details the timing characteristics of the Planacon PMT. Using a radioactive $^{22}$Na source we measured a detection efficiency of 24% for 511 keV photons in a 10 mm thick crystal and a coincidence resolving time of 280 ps. We analyzed the main factors limiting the time resolution of the large-surface detection module and proposed solutions to improve it, which will be tested in our future project.

physics.ins-det

Ionization parameters of Trimethylbismuth for high-energy photon detection

CaLIPSO is an innovative photon detector concept designed for high precision brain PET imaging. For the first time, liquid trimethylbismuth is used as sensitive medium. The detector operates as a time-projection chamber and detects both Cherenkov light and charge signal. Indeed, each 511-keV photon releases a single primary electron that triggers a Cherenkov radiation and ionizes the medium. As trimethylbismuth has never been studied before, we measured its free ion yield defined as the number of electron-ion pairs released by the primary electron. To this end, we developed a low-noise measuring system to determine the weak current induced by a 60Co source in the liquid with an accuracy better than 5 fA for an electric field up to 7kV/cm. We used tetramethylsilane as benchmark liquid to validate the apparatus and we measured a zero-field free ion yield of 0.53 +/- 0.03 in agreement with literature. However, we found a zero-field free ion yield of 0.083 +/- 0.003 for trimethylbismuth, which is a factor 7 lower than the typical values for similar dielectric liquids. Quantum chemistry computations on heavy atoms tend to demonstrate the high ability of trimethylbismuth to capture electrons, which could explain this weak value. This recombination mechanism marks a new step in understanding charge transport in liquid detectors. Finally, to verify the detectability of individual charge pulses, we developed a charge pulse measurement system which has been successfully validated with TMSi. Measurements with TMBi are ongoing.

physics.ins-det

Free ion yield of Trimethyl Bismuth used as sensitive medium for high-energy photon detection

The CaLIPSO project is an innovative high-energy photon detector concept using trimethylbismuth as sensitive medium in a liquid ionization chamber. The detector, designed for high precision brain PET imaging, works as a time-projection chamber and detects Cherenkov light and charge signal. We measured the free ion yield of trimethylbismuth, which represents the number of electron-ion pairs released by the incident photon. To do so, we developed a low-noise measuring system to determine the current induced by a 60Co source in the liquid with an accuracy better than 5 fA for an electric field up to 7 kV/cm. We used tetramethylsilane as benchmark liquid to validate the apparatus and we measured a zero-field free ion yield of 0.53 +/- 0.03 in agreement with measurements in literature. However, we found a zero-field free ion yield of 0.083 +/- 0.003 for trimethylbismuth, which is a factor 7 lower than the typical values for similar dielectric liquids. Quantum chemistry computations on heavy atoms tend to demonstrate a high capacity of trimethylbismuth to capture electrons which could explain the weak value. The consequences of a low free ion yield in terms of high-energy photon detection and brain PET imaging are finally discussed.

physics.ins-det

New determinations of gamma-ray line intensities of the Ep = 550 keV and Ep = 1747 keV resonances of the 13-C(p,gamma)14-N reaction

Gamma-ray angular distributions for the resonances at Ep = 550 keV and 1747 keV of the radiative capture reaction 13-C(p,g)14-N have been measured, using intense proton beams on isotopically pure 13-C targets. Relative intensities for the strongest transitions were extracted with an accuracy of typically five per cent, making these resonances new useful gamma-ray standards for efficiency calibration in the energy range Egamma = 1.6 to 9 MeV.

nucl-ex

INTEGRAL/SPI ground calibration

Three calibration campaigns of the spectrometer SPI have been performed before launch in order to determine the instrument characteristics, such as the effective detection area, the spectral resolution and the angular resolution. Absolute determination of the effective area has been obtained from simulations and measurements. At 1 MeV, the effective area is 65 cm^2 for a point source on the optical axis, the spectral resolution ~2.3 keV. The angular resolution is better than 2.5 deg and the source separation capability about 1 deg. Some temperature dependant parameters will require permanent in-flight calibration.

astro-ph