SearcharxivSearch

arXiv subjects

G. Varner

Publications and source records attributed to G. Varner.

28 records · Page 2Linked to original sources

IceRay: An IceCube-centered Radio-Cherenkov GZK Neutrino Detector

We discuss design considerations and simulation results for IceRay, a proposed large-scale ultra-high energy (UHE) neutrino detector at the South Pole. The array is designed to detect the coherent Askaryan radio emission from UHE neutrino interactions in the ice, with the goal of detecting the cosmogenic neutrino flux with reasonable event rates. Operating in coincidence with the IceCube neutrino detector would allow complete calorimetry of a subset of the events. We also report on the status of a testbed IceRay station which incorporates both ANITA and IceCube technology and will provide year-round monitoring of the radio environment at the South Pole.

astro-ph.HE

New Limits on the Ultra-high Energy Cosmic Neutrino Flux from the ANITA Experiment

We report initial results of the first flight of the Antarctic Impulsive Transient Antenna (ANITA-1) 2006-2007 Long Duration Balloon flight, which searched for evidence of a diffuse flux of cosmic neutrinos above energies of 3 EeV. ANITA-1 flew for 35 days looking for radio impulses due to the Askaryan effect in neutrino-induced electromagnetic showers within the Antarctic ice sheets. We report here on our initial analysis, which was performed as a blind search of the data. No neutrino candidates are seen, with no detected physics background. We set model-independent limits based on this result. Upper limits derived from our analysis rule out the highest cosmogenic neutrino models. In a background horizontal-polarization channel, we also detect six events consistent with radio impulses from ultra-high energy extensive air showers.

astro-ph

The Antarctic Impulsive Transient Antenna Ultra-high Energy Neutrino Detector Design, Performance, and Sensitivity for 2006-2007 Balloon Flight

We present a detailed report on the experimental details of the Antarctic Impulsive Transient Antenna (ANITA) long duration balloon payload, including the design philosophy and realization, physics simulations, performance of the instrument during its first Antarctic flight completed in January of 2007, and expectations for the limiting neutrino detection sensitivity. Neutrino physics results will be reported separately.

astro-ph

Hanohano:A Deep Ocean Antineutrino Observatory

This paper presents the science potential of a deep ocean antineutrino observatory being developed at Hawaii and elsewhere. The observatory design allows for relocation from one site to another. Positioning the observaory some 60 km distant from a nuclear reactor complex enables preecision measurement of neutrino mixing parameters, leading to a determination of neutrino mass hierarchy and theta_13. At a mid-Pacific location, the observatory measures the flux of uranium and thorium decay series antineutrinos from earth's mantle and performs a sensitive search for a hypothetical natural fission reactor in earth's core. A subequent deployment at another mid-ocean location would test lateral homogeneity of uranium and thorium in earth's mantle. These measurements have significance for earth energy studies.

hep-ex

Measuring energy dependent polarization in soft gamma-rays using Compton scattering in PoGOLite

Linear polarization in X- and gamma-rays is an important diagnostic of many astrophysical sources, foremost giving information about their geometry, magnetic fields, and radiation mechanisms. However, very few X-ray polarization measurements have been made, and then only mono-energetic detections, whilst several objects are assumed to have energy dependent polarization signatures. In this paper we investigate whether detection of energy dependent polarization from cosmic sources is possible using the Compton technique, in particular with the proposed PoGOLite balloon-experiment, in the 25-100 keV range. We use Geant4 simulations of a PoGOLite model and input photon spectra based on Cygnus X-1 and accreting magnetic pulsars (100 mCrab). Effective observing times of 6 and 35 hours were simulated, corresponding to a standard and a long duration flight respectively. Both smooth and sharp energy variations of the polarization are investigated and compared to constant polarization signals using chi-square statistics. We can reject constant polarization, with energy, for the Cygnus X-1 spectrum (in the hard state), if the reflected component is assumed to be completely polarized, whereas the distinction cannot be made for weaker polarization. For the accreting pulsar, constant polarization can be rejected in the case of polarization in a narrow energy band with at least 50% polarization, and similarly for a negative step distribution from 30% to 0% polarization.

astro-ph

Earth Radioactivity Measurements with a Deep Ocean Anti-neutrino Observatory

We consider the detector size, location, depth, background, and radio-purity required of a mid-Pacific deep-ocean instrument to accomplish the twin goals of making a definitive measurement of the electron anti-neutrino flux due to uranium and thorium decays from Earth's mantle and core, and of testing the hypothesis for a natural nuclear reactor at the core of Earth. We take the experience with the KamLAND detector in Japan as our baseline for sensitivity and background estimates. We conclude that an instrument adequate to accomplish these tasks should have an exposure of at least 10 kilotonne-years (kT-y), should be placed at least at 4 km depth, may be located close to the Hawaiian Islands (no significant background from them), and should aim for KamLAND radio-purity levels, except for radon where it should be improved by a factor of at least 100. With an exposure of 10 kT-y we should achieve a 24% measurement of the U/Th content of the mantle plus core. Exposure at multiple ocean locations for testing lateral heterogeneity is possible.

hep-ex

The Data Acquisition System Based on PMC Bus

High energy physics experiments in KEK/Japan rush into over KHz trigger stage. Thus, we need a successor of the data acquisition(DAQ) system that replaces the CAMAC or FASTBUS systems. To meet these needs, we have developed a DAQ system which includes a crate, base-board modules, daughter cards for front-end A/D or T/D conversion, and back-end communication cards for data transfer and timing control. The size of the crate is for the 9U Euro-cards with the standard VME32 bus and extension connectors for power supply. The base-board comprises of a local bus with the sequencer connected to the front-end daughter cards via event buffering FIFOs, and the standard PMC (PCI mezzanine card) bus to be set a PMC processor unit to reduce data size from the front-end daughter cards. A data transfer module, which is connected to the event building system, and a trigger control unit, which communicates with the central timing controller are installed on the back-end communication card connected to the rear end of the base-board. We describe the design of this DAQ system and evaluate the performance of it.

physics.ins-det

Development of a PCI Based Data Acquisition Platform for High Intensity Accelerator Experiments

Data logging at an upgraded KEKB accelerator or the J-PARC facility, currently under commission, requires a high density data acquisition platform with integrated data reduction CPUs. To follow market trends, we have developed a DAQ platform based on the PCI bus, a choice which permits a fast DAQ and a long expected lifetime of the system. The platform is a 9U-VME motherboard consisting of four slots for signal digitization modules, readout FIFOs for data buffering, and three PMC slots, on one of which resides a data reduction CPU. We have performed long term and thermal stability tests. The readout speed on the platform has been measured up to 125 MB/s in DMA mode.

hep-ex

A Detailed Monte-Carlo Simulation for the Belle TOF System

We have developed a detailed Monte Carlo simulation program for the Belle TOF system. Based on GEANT simulation, it takes account of all physics processes in the TOF scintillation counters and readout electronics. The simulation reproduces very well the performance of the Belle TOF system, including the dE/dx response, the time walk effect, the time resolution, and the hit efficiency due to beam background. In this report, we will describe the Belle TOF simulation program in detail.

hep-ex

The Cherenkov Correlated Timing Detector: Beam Test Results from Quartz and Acrylic Bars

Several prototypes of a Cherenkov Correlated Timing (CCT) Detector have been tested at the KEK-PS test beam line. We describe the results for Cherenkov light yields and timing characteristics from quartz and acrylic bar prototypes. A Cherenkov angle resolution is found to be 15 mrad at a propagation distance of 100 cm with a 2 cm thick quartz bar prototype.

hep-ex