Searcharxiv⌕ Search

arXiv subjects

G. Wang

Publications and source records attributed to G. Wang.

At least 37 records · Page 2Linked to original sources

Results from a Prototype TES Detector for the Ricochet Experiment

Coherent elastic neutrino-nucleus scattering (CE$ν$NS) offers valuable sensitivity to physics beyond the Standard Model. The Ricochet experiment will use cryogenic solid-state detectors to perform a precision measurement of the CE$ν$NS spectrum induced by the high neutrino flux from the Institut Laue-Langevin nuclear reactor. The experiment will employ an array of detectors, each with a mass of $\sim$30 g and a targeted energy threshold of 50 eV. Nine of these detectors (the "Q-Array") will be based on a novel Transition-Edge Sensor (TES) readout style, in which the TES devices are thermally coupled to the absorber using a gold wire bond. We present initial characterization of a Q-Array-style detector using a 1 gram silicon absorber, obtaining a baseline root-mean-square resolution of less than 40 eV.

physics.ins-det↗

Modeling and characterization of TES-based detectors for the Ricochet experiment

Coherent elastic neutrino-nucleus scattering (CE$ν$NS) offers a valuable approach in searching for physics beyond the Standard Model. The Ricochet experiment aims to perform a precision measurement of the CE$ν$NS spectrum at the Institut Laue-Langevin nuclear reactor with cryogenic solid-state detectors. The experiment plans to employ an array of cryogenic thermal detectors, each with a mass around 30 g and an energy threshold of sub-100 eV. The array includes nine detectors read out by Transition-Edge Sensors (TES). These TES based detectors will also serve as demonstrators for future neutrino experiments with thousands of detectors. In this article we present an update in the characterization and modeling of a prototype TES detector.

hep-ex↗

A Measurement of the CMB Temperature Power Spectrum and Constraints on Cosmology from the SPT-3G 2018 TT/TE/EE Data Set

We present a sample-variance-limited measurement of the temperature power spectrum ($TT$) of the cosmic microwave background (CMB) using observations of a $\sim\! 1500 \,\mathrm{deg}^2$ field made by SPT-3G in 2018. We report multifrequency power spectrum measurements at 95, 150, and 220GHz covering the angular multipole range $750 \leq \ell < 3000$. We combine this $TT$ measurement with the published polarization power spectrum measurements from the 2018 observing season and update their associated covariance matrix to complete the SPT-3G 2018 $TT/TE/EE$ data set. This is the first analysis to present cosmological constraints from SPT $TT$, $TE$, and $EE$ power spectrum measurements jointly. We blind the cosmological results and subject the data set to a series of consistency tests at the power spectrum and parameter level. We find excellent agreement between frequencies and spectrum types and our results are robust to the modeling of astrophysical foregrounds. We report results for $Λ$CDM and a series of extensions, drawing on the following parameters: the amplitude of the gravitational lensing effect on primary power spectra $A_\mathrm{L}$, the effective number of neutrino species $N_{\mathrm{eff}}$, the primordial helium abundance $Y_{\mathrm{P}}$, and the baryon clumping factor due to primordial magnetic fields $b$. We find that the SPT-3G 2018 $T/TE/EE$ data are well fit by $Λ$CDM with a probability-to-exceed of $15\%$. For $Λ$CDM, we constrain the expansion rate today to $H_0 = 68.3 \pm 1.5\,\mathrm{km\,s^{-1}\,Mpc^{-1}}$ and the combined structure growth parameter to $S_8 = 0.797 \pm 0.042$. The SPT-based results are effectively independent of Planck, and the cosmological parameter constraints from either data set are within $<1\,σ$ of each other. (abridged)

astro-ph.CO↗

Emergence of high-temperature superconducting phase in the pressurized La3Ni2O7 crystals

The recent report of pressure-induced structure transition and signature of superconductivity with Tc = 80 K above 14 GPa in the La3Ni2O7 crystals has garnered considerable attention. To further elaborate this discovery, we carried out comprehensive resistance measurements on the La3Ni2O7 crystals grown with the optical-image floating zone furnace under oxygen pressure (15 bar) by using the diamond anvil cell (DAC) and cubic anvil cell (CAC), which employs the solid and liquid pressure transmitting medium, respectively. For the sample #1 measured in DAC, it exhibits a semiconducting-like behavior with large resistance at low pressures and becomes metallic gradually upon compression. At the pressures P >= 13.7 GPa, we observed the appearance of resistance drop as large as ~50% around 70 K, which evolves into a kink-like anomaly at pressures above 40 GPa and shifts to lower temperatures gradually with increasing magnetic field. These observations are consistent with the recent report mentioned above. On the other hand, the sample #2 measured in CAC retains the metallic behavior in the investigated pressure range up to 15 GPa. The hump-like anomaly in resistance around ~130 K at ambient pressure disappears at P >= 2 GPa. In the pressure range from 11 to 15 GPa, we observed the gradual development of a shoulder-like anomaly in resistance at low temperatures, which evolves into a pronounced drop of resistance by 98% below 62 K at 15 GPa, reaching a temperature-independent resistance of 20 uOhm below 20 K. Similarly, this resistance anomaly can be shifted to lower temperatures progressively by applying external magnetic fields, resembling a typical superconducting transition.

cond-mat.supr-con↗

Improved Calibration of RF Cavities for Relativistic Electron Beams: Effects of Secondary Corrections and Experimental Verification

In the aspect of longitudinal beam bunching, the bunching strength can be controlled by the RF cavity phase and voltage. However, these machine parameters are different from those that interact with the beam itself. In order to gain control of the beam-cavity interaction, cavity calibration must be performed. Furthermore, it relies on fitting the beam energy gain versus cavity phase to a calibration function. Under the conventional assumption of relativistic beam conditions, the calibration function is a first harmonic sinusoidal function (a sinusoidal function with a period of 2π). However, this expression is insufficient for a high-voltage bunching cavity. Due to beam acceleration inside the cavity, an energy bias and a second harmonic function should be included to modify the conventional calibration function, even for a relativistic electron beam. In this paper, we will derive this modification and provide a comparison to both the Coherent Electron Cooling Experiment and the IMPACT-T simulation, respectively.

physics.acc-ph↗

Snowmass2021 Cosmic Frontier: The landscape of low-threshold dark matter direct detection in the next decade

The search for particle-like dark matter with meV-to-GeV masses has developed rapidly in the past few years. We summarize the science case for these searches, the recent progress, and the exciting upcoming opportunities. Funding for Research and Development and a portfolio of small dark matter projects will allow the community to capitalize on the substantial recent advances in theory and experiment and probe vast regions of unexplored dark-matter parameter space in the coming decade.

hep-ph↗

Quasiparticle Generation-Recombination Noise in the Limit of Low Detector Volume

We have measured the quasiparticle generation-recombination (GR) noise in aluminium lumped element kinetic inductors with a wide range of detector volumes at various temperatures. The basic detector consists of meandering inductor and interdigitated capacitor fingers. The inductor volume is varied from 2 to 153 μm^{3} by changing the inductor width and length to maintain a constant inductance. We started with measuring the power spectrum density (PSD) of the detectors frequency noise which is a function of GR noise and we clearly observed the spectrum roll off at 10 kHz which corresponds to the quasiparticle lifetime. Using data from a temperature sweep of the resonator frequency we convert the frequency fluctuation to quasiparticle fluctuation and observe its strong dependence on detector volume: detectors with smaller volume display less quasiparticle noise amplitude. Meanwhile we observe a saturated quasiparticle density at low temperature from all detectors as the quasiparticle life time τqp approaches a constant value at low temperature.

astro-ph.IM↗

Noise Optimization for MKIDs with Different Design Geometries and Material Selections

The separation and optimization of noise components is critical to microwave-kinetic inductance detector (MKID) development. We analyze the effect of several changes to the lumped-element inductor and interdigitated capacitor geometry on the noise performance of a series of MKIDs intended for millimeter-wavelength experiments. We extract the contributions from two-level system noise in the dielectric layer, the generation-recombination noise intrinsic to the superconducting thin-film, and system white noise from each detector noise power spectrum and characterize how these noise components depend on detector geometry, material, and measurement conditions such as driving power and temperature. We observe a reduction in the amplitude of two-level system noise with both an elevated sample temperature and an increased gap between the fingers within the interdigitated capacitors for both aluminum and niobium detectors. We also verify the expected reduction of the generation-recombination noise and associated quasiparticle lifetime with reduced inductor volume. This study also iterates over different materials, including aluminum, niobium, and aluminum manganese, and compares the results with an underlying physical model.

astro-ph.IM↗

Fabrication Development for SPT-SLIM, a Superconducting Spectrometer for Line Intensity Mapping

Line Intensity Mapping (LIM) is a new observational technique that uses low-resolution observations of line emission to efficiently trace the large-scale structure of the Universe out to high redshift. Common mm/sub-mm emission lines are accessible from ground-based observatories, and the requirements on the detectors for LIM at mm-wavelengths are well matched to the capabilities of large-format arrays of superconducting sensors. We describe the development of an R = 300 on-chip superconducting filter-bank spectrometer covering the 120--180 GHz band optimized for future mm-LIM experiments, focusing on SPT-SLIM, a pathfinder LIM instrument for the South Pole Telescope. Radiation is coupled from the telescope optical system to the spectrometer chip via an array of feedhorn-coupled orthomode transducers. Superconducting microstrip transmission lines then carry the signal to an array of channelizing half-wavelength resonators, and the output of each spectral channel is sensed by a lumped element kinetic inductance detector (leKID). Key areas of development include incorporating new low-loss dielectrics to improve both the achievable spectral resolution and optical efficiency and development of a robust fabrication process to create a galvanic connection between ultra-pure superconducting thin-films to realize multi-material (hybrid) leKIDs. We provide an overview of the spectrometer design, fabrication process, and prototype devices.

astro-ph.IM↗

Low-loss Si-based Dielectrics for High Frequency Components of Superconducting Detectors

Silicon-based dielectric is crucial for many superconducting devices, including high-frequency transmission lines, filters, and resonators. Defects and contaminants in the amorphous dielectric and at the interfaces between the dielectric and metal layers can cause microwave losses and degrade device performance. Optimization of the dielectric fabrication, device structure, and surface morphology can help mitigate this problem. We present the fabrication of silicon oxide and nitride thin film dielectrics. We then characterized them using Scanning Electron Microscopy, Atomic Force Microscopy, and spectrophotometry techniques. The samples were synthesized using various deposition methods, including Plasma-Enhanced Chemical Vapor Deposition and magnetron sputtering. The films morphology and structure were modified by adjusting the deposition pressure and gas flow. The resulting films were used in superconducting resonant systems consisting of planar inductors and capacitors. Measurements of the resonator properties, including their quality factor, were performed.

astro-ph.IM↗

Measurement of Dielectric Loss in Silicon Nitride at Centimeter and Millimeter Wavelengths

This work presents a suite of measurement techniques for characterizing the dielectric loss tangent across a wide frequency range from $\sim$1 GHz to 150 GHz using the same test chip. In the first method, we fit data from a microwave resonator at different temperatures to a model that captures the two-level system (TLS) response to extract and characterize both the real and imaginary components of the dielectric loss. The inverse of the internal quality factor is a second measure of the overall loss of the resonator, where TLS loss through the dielectric material is typically the dominant source. The third technique is a differential optical measurement at 150 GHz. The same antenna feeds two microstrip lines with different lengths that terminate in two microwave kinetic inductance detectors (MKIDs). The difference in the detector response is used to estimate the loss per unit length of the microstrip line. Our results suggest a larger loss for SiN$_x$ at 150 GHz of ${\mathrm{\tan δ\sim 4\times10^{-3}}}$ compared to ${\mathrm{2.0\times10^{-3}}}$ and ${\mathrm{\gtrsim 1\times10^{-3}}}$ measured at $\sim$1 GHz using the other two methods. {These measurement techniques can be applied to other dielectrics by adjusting the microstrip lengths to provide enough optical efficiency contrast and other mm/sub-mm frequency ranges by tuning the antenna and feedhorn accordingly.

astro-ph.IM↗

Electromagnetic Properties of Aluminum-based Bilayers for Kinetic Inductance Detectors

The complex conductivity of a superconducting thin film is related to the quasiparticle density, which depends on the physical temperature and can also be modified by external pair breaking with photons and phonons. This relationship forms the underlying operating principle of Kinetic Inductance Detectors (KIDs), where the detection threshold is governed by the superconducting energy gap. We investigate the electromagnetic properties of thin-film aluminum that is proximitized with either a normal metal layer of copper or a superconducting layer with a lower $T_C$, such as iridium, in order to extend the operating range of KIDs. Using the Usadel equations along with the Nam expressions for complex conductivity, we calculate the density of states and the complex conductivity of the resulting bilayers to understand the dependence of the pair breaking threshold, surface impedance, and intrinsic quality factor of superconducting bilayers on the relative film thicknesses. The calculations and analyses provide theoretical insights in designing aluminum-based bilayer kinetic inductance detectors for detection of microwave photons and athermal phonons at the frequencies well below the pair breaking threshold of a pure aluminum film.

astro-ph.IM↗

The young mini-Neptune HD 207496b that is either a naked core or on the verge of becoming one

We report the discovery and characterisation of the transiting mini-Neptune HD~207496~b (TOI-1099) as part of a large programme that aims to characterise naked core planets. We obtained HARPS spectroscopic observations, one ground-based transit, and high-resolution imaging which we combined with the TESS photometry to confirm and characterise the TESS candidate and its host star. The host star is an active early K dwarf with a mass of $0.80 \pm 0.04\,$M$_\odot$, a radius of $0.769 \pm 0.026\,$R$_\odot$, and a G magnitude of 8. We found that the host star is young, $\sim 0.52\,$ Myr, allowing us to gain insight into planetary evolution. We derived a planetary mass of $6.1 \pm 1.6\,\mathrm{M}_E$,\, a planetary radius of $2.25 \pm 0.12\,\mathrm{R}_E$,\ and a planetary density of $ρ_p = 3.27_{-0.91}^{+0.97}\,\mathrm{g.cm^{-3}}$. From internal structure modelling of the planet, we conclude that the planet has either a water-rich envelope, a gas-rich envelope, or a mixture of both. We have performed evaporation modelling of the planet. If we assume the planet has a gas-rich envelope, we find that the planet has lost a significant fraction of its envelope and its radius has shrunk. Furthermore, we estimate it will lose all its remaining gaseous envelope in $\sim 0.52\,$ Gyr. Otherwise, the planet could have already lost all its primordial gas and is now a bare ocean planet. Further observations of its possible atmosphere and/or mass-loss rate would allow us to distinguish between these two hypotheses. Such observations would determine if the planet remains above the radius gap or if it will shrink and be below the gap.

astro-ph.EP↗

Simultaneous Millimeter-wave, Gamma-ray, and Optical Monitoring of the Blazar PKS 2326-502 During a Flaring State

Including millimeter-wave (mm-wave) data in multi-wavelength studies of the variability of active galactic nuclei (AGN) can provide insights into AGN physics that are not easily accessible at other wavelengths. We demonstrate in this work the potential of cosmic microwave background (CMB) telescopes to provide long-term, high-cadence mm-wave AGN monitoring over large fractions of sky. We report on a pilot study using data from the SPTpol instrument on the South Pole Telescope (SPT), which was designed to observe the CMB at arcminute and larger angular scales. Between 2013 and 2016, SPTpol was used primarily to observe a single 500 deg^2 field, covering the entire field several times per day with detectors sensitive to radiation in bands centered at 95 and 150 GHz. We use SPT 150 GHz observations to create AGN light curves, and we compare these mm-wave light curves to those at other wavelengths, in particular gamma-ray and optical. In this Letter, we focus on a single source, PKS 2326-502, which has extensive, day-timescale monitoring data in gamma-ray, optical, and now mm-wave between 2013 and 2016. We find PKS 2326-502 to be in a flaring state in the first two years of this monitoring, and we present a search for evidence of correlated variability between mm-wave, optical R band, and gamma-ray observations. This pilot study is paving the way for AGN monitoring with current and upcoming CMB experiments such as SPT-3G, Simons Observatory, and CMB-S4, including multi-wavelength studies with facilities such as VRO-LSST.

astro-ph.HE↗

Observation of Long-Radial-Range-Correlation in Turbulence in High-Collisionality High-Confinement Fusion Plasmas

We report on the observation of spatially asymmetric turbulent structures with a long radial correlation length in the core of high-collisionality H-mode plasmas on DIII-D tokamak. These turbulent structures develop from shorter wavelength turbulence and have a radially elongated structure. The envelope of turbulence spans a broad radial range in the mid-radius region, leading to streamer-like transport events. The underlying turbulence is featured by intermittency, long-term memory effect, and the characteristic spectrum of self-organized criticality. The amplitude and the radial scale increase substantially when the shearing rate of the mean flow is reduced below the turbulent scattering rate. The enhanced LRRC transport events are accompanied by apparent degradation of normalized energy confinement time. These findings constitute the first experimental observation of long-radial-range turbulent transport events in high-collisionality H-mode plasmas, and demonstrate the role of mean shear flows in the formation and propagation of turbulence with long-radial-range correlation.

physics.plasm-ph↗

A portable and high intensity 24 keV neutron source based on $^{124}$Sb-$^{9}$Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the $^{124}$Sb-$^9$Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from $^{124}$Sb decays while letting through the neutrons. To increase the $^{124}$Sb activity and thus the neutron flux, a $>$1 GBq $^{124}$Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20-25 keV to be 5.36$\pm$0.20 neutrons per cm$^2$ per second and the total gamma flux to be 213$\pm$6 gammas per cm$^2$ per second (numbers scaled to 1 GBq activity of the $^{124}$Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

physics.ins-det↗

QCD Phase Structure and Interactions at High Baryon Density: Continuation of BES Physics Program with CBM at FAIR

We advocate for an active US participation in the international collaboration of the CBM experiment that will allow the US nuclear physics program to build on its successful exploration of the QCD phase diagram, use the expertise gained at RHIC to make complementary measurements at FAIR, and contribute to achieving the scientific goals of the beam energy scan (BES) program.

nucl-ex↗

Electrostatic control of the proximity effect in the bulk of semiconductor-superconductor hybrids

The proximity effect in semiconductor-superconductor nanowires is expected to generate an induced gap in the semiconductor. The magnitude of this induced gap, together with the semiconductor properties like the spin-orbit coupling and $g$\,-\,factor, depends on the coupling between the materials. It is predicted that this coupling can be adjusted through the use of electric fields. We study this phenomena in InSb/Al/Pt hybrids using nonlocal spectroscopy. We show that these hybrids can be tuned such that the semiconductor and superconductor are strongly coupled. In this case, the induced gap is similar to the superconducting gap in the Al/Pt shell and closes only at high magnetic fields. In contrast, the coupling can be suppressed which leads to a strong reduction of the induced gap and critical magnetic field. At the crossover between the strong-coupling and weak-coupling regimes, we observe the closing and reopening of the induced gap in the bulk of a nanowire. Contrary to expectations, it is not accompanied by the formation of zero-bias peaks in the local conductance spectra. As a result, this cannot be attributed conclusively to the anticipated topological phase transition and we discuss possible alternative explanations.

cond-mat.supr-con↗