The optical calcium frequency standards of PTB and NIST

We describe the current status of the Ca optical frequency standards with laser-cooled neutral atoms realized in two different laboratories for the purpose of developing a possible future optical atomic clock. Frequency measurements performed at the Physikalisch-Technische Bundesanstalt (PTB) and the National Institute of Standards and Technology (NIST) make the frequency of the clock transition of 40Ca one of the best known optical frequencies (relative uncertainty 1.2e-14) and the measurements of this frequency in both laboratories agree to well within their respective uncertainties. Prospects for improvement by orders of magnitude in the relative uncertainty of the standard look feasible.

physics.atom-ph

Observation of Large Atomic-Recoil Induced Asymmetries in Cold Atom Spectroscopy

The atomic recoil effect leads to large (25 %) asymmetries in simple spectroscopic investigations of Ca atoms that have been laser-cooled to 10 microkelvin. Starting with spectra from the more familiar Doppler-broadened domain, we show how the fundamental asymmetry between absorption and stimulated emission of light manifests itself when shorter spectroscopic pulses lead to the Fourier transform regime. These effects occur on frequency scales much larger than the size of the recoil shift itself, and have not been observed before in saturation spectroscopy. These results are relevant to state-of-the-art optical atomic clocks based on freely expanding neutral atoms.

physics.atom-ph

Photoassociation spectroscopy of cold calcium atoms

Photoassociation spectroscopy experiments on 40Ca atoms close to the dissociation limit 4s4s 1S0 - 4s4p 1P1 are presented. The vibronic spectrum was measured for detunings of the photoassociation laser ranging from 0.6 GHz to 68 GHz with respect to the atomic resonance. In contrast to previous measurements the rotational splitting of the vibrational lines was fully resolved. Full quantum mechanical numerical simulations of the photoassociation spectrum were performed which allowed us to put constraints on the possible range of the calcium scattering length to between 50 a_0 and 300 a_0.

physics.atom-ph

An Optical Clock with Ultracold Neutral Atoms

We demonstrate how to realize an optical clock with neutral atoms that is competitive to the currently best single ion optical clocks in accuracy and superior in stability. Using ultracold atoms in a Ca optical frequency standard we show how to reduce the relative uncertainty to below 1E-15. We observed atom interferences for stabilization of the laser to the clock transition with a visibility of 0.36, which is 70 % of the ultimate limit achievable with atoms at rest. A novel scheme was applied to detect these atom interferences with the prospect to reach the quantum projection noise limit at an exceptional low instability of 4E-17 in 1 s.

physics.atom-ph

Doppler cooling and trapping on forbidden transitions

Ultracold atoms at temperatures close to the recoil limit have been achieved by extending Doppler cooling to forbidden transitions. A cloud of ^40Ca atoms has been cooled and trapped to a temperature as low as 6 μK by operating a magneto-optical trap on the spin-forbidden intercombination transition. Quenching the long-lived excited state with an additional laser enhanced the scattering rate by a factor of 15, while a high selectivity in velocity was preserved. With this method more than 10% of pre-cooled atoms from a standard magneto-optical trap have been transferred to the ultracold trap. Monte-Carlo simulations of the cooling process are in good agreement with the experiments.

physics.atom-ph

Phase-coherent frequency measurement of the Ca intercombination line at 657 nm with a Kerr-lens mode-locked femtosecond laser

The frequency of the Calcium ^3P_1--^1S_0 intercombination line at 657 nm is phase-coherently measured in terms of the output of a primary cesium frequency standard using an optical frequency comb generator comprising a sub-10 fs Kerr-lens mode-locked Ti:Sapphire laser and an external microstructure fiber for self-phase-modulation. The measured frequency of ν_Ca = 455 986 240 494 276 Hz agrees within its relative uncertainty of 4 10^-13 with the values previously measured with a conceptually different harmonic frequency chain and with the value recommended for the realization of the SI unit of length.