SearcharxivSearch

arXiv subjects

GERDA collaboration

Publications and source records attributed to GERDA collaboration.

11 recordsLinked to original sources

Final Results of GERDA on the Two-Neutrino Double-$\beta$ Decay Half-Life of $^{76}$Ge

We present the measurement of the two-neutrino double-$\beta$ decay rate of $^{76}$Ge performed with the GERDA Phase II experiment. With a subset of the entire GERDA exposure, 11.8 kg$\cdot$yr, the half-life of the process has been determined: $T^{2\nu}_{1/2} = (2.022 \pm 0.018_{stat} \pm 0.038_{sys})\times10^{21}$ yr. This is the most precise determination of the $^{76}$Ge two-neutrino double-$\beta$ decay half-life and one of the most precise measurements of a double-$\beta$ decay process. The relevant nuclear matrix element can be extracted: $M^{2\nu}_{\text{eff}} = (0.101\pm0.001).$

nucl-ex

Search for tri-nucleon decays of $^{76}$Ge in GERDA

We search for tri-nucleon decays of $^{76}$Ge in the dataset from the GERmanium Detector Array (GERDA) experiment. Decays that populate excited levels of the daughter nucleus above the threshold for particle emission lead to disintegration and are not considered. The ppp-, ppn-, and pnn-decays lead to $^{73}$Cu, $^{73}$Zn, and $^{73}$Ga nuclei, respectively. These nuclei are unstable and eventually proceed by the beta decay of $^{73}$Ga to $^{73}$Ge (stable). We search for the $^{73}$Ga decay exploiting the fact that it dominantly populates the 66.7 keV $^{73m}$Ga state with half-life of 0.5 s. The nnn-decays of $^{76}$Ge that proceed via $^{73m}$Ge are also included in our analysis. We find no signal candidate and place a limit on the sum of the decay widths of the inclusive tri-nucleon decays that corresponds to a lower lifetime limit of 1.2x10$^{26}$ yr (90% credible interval). This result improves previous limits for tri-nucleon decays by one to three orders of magnitude.

nucl-ex

Liquid argon light collection and veto modeling in GERDA Phase II

The ability to detect liquid argon scintillation light from within a densely packed high-purity germanium detector array allowed the GERDA experiment to reach an exceptionally low background rate in the search for neutrinoless double beta decay of $^{76}$Ge. Proper modeling of the light propagation throughout the experimental setup, from any origin in the liquid argon volume to its eventual detection by the novel light read-out system, provides insight into the rejection capability and is a necessary ingredient to obtain robust background predictions. In this paper, we present a model of the GERDA liquid argon veto, as obtained by Monte Carlo simulations and constrained by calibration data, and highlight its application for background decomposition.

physics.ins-det

Characterization of inverted coaxial $^{76}$Ge detectors in GERDA for future double-$\beta$ decay experiments

Neutrinoless double-$\beta$ decay of $^{76}$Ge is searched for with germanium detectors where source and detector of the decay are identical. For the success of future experiments it is important to increase the mass of the detectors. We report here on the characterization and testing of five prototype detectors manufactured in inverted coaxial (IC) geometry from material enriched to 88% in $^{76}$Ge. IC detectors combine the large mass of the traditional semi-coaxial Ge detectors with the superior resolution and pulse shape discrimination power of point contact detectors which exhibited so far much lower mass. Their performance has been found to be satisfactory both when operated in vacuum cryostat and bare in liquid argon within the GERDA setup. The measured resolutions at the Q-value for double-$\beta$ decay of $^{76}$Ge (Q$_{\beta\beta}$ = 2039 keV) are about 2.1 keV full width at half maximum in vacuum cryostat. After 18 months of operation within the ultra-low background environment of the GERmanium Detector Array (GERDA) experiment and an accumulated exposure of 8.5 kg$\cdot$yr, the background index after analysis cuts is measured to be $4.9^{+7.3}_{-3.4}\times 10^{-4}$ counts /(keV$\cdot$kg$\cdot$yr) around Q$_{\beta\beta}$. This work confirms the feasibility of IC detectors for the next-generation experiment LEGEND.

physics.ins-det

Calibration of the GERDA experiment

The GERmanium Detector Array (GERDA) collaboration searched for neutrinoless double-$\beta$ decay in $^{76}$Ge with an array of about 40 high-purity isotopically-enriched germanium detectors. The experimental signature of the decay is a monoenergetic signal at Q$_{\beta\beta}$ = 2039.061(7)keV in the measured summed energy spectrum of the two emitted electrons. Both the energy reconstruction and resolution of the germanium detectors are crucial to separate a potential signal from various backgrounds, such as neutrino-accompanied double-$\beta$ decays allowed by the Standard Model. The energy resolution and stability were determined and monitored as a function of time using data from regular $^{228}$Th calibrations. In this work, we describe the calibration process and associated data analysis of the full GERDA dataset, tailored to preserve the excellent resolution of the individual germanium detectors when combining data over several years.

physics.ins-det

Final Results of GERDA on the Search for Neutrinoless Double-$\beta$ Decay

The GERmanium Detector Array (GERDA) experiment searched for the lepton-number-violating neutrinoless double-$\beta$ ($0\nu\beta\beta$) decay of $^{76}$Ge, whose discovery would have far-reaching implications in cosmology and particle physics. By operating bare germanium diodes, enriched in $^{76}$Ge, in an active liquid argon shield, GERDA achieved an unprecedently low background index of $5.2\times10^{-4}$ counts/(keV$\cdot$kg$\cdot$yr) in the signal region and met the design goal to collect an exposure of 100 kg$\cdot$yr in a background-free regime. When combined with the result of Phase I, no signal is observed after 127.2 kg$\cdot$yr of total exposure. A limit on the half-life of $0\nu\beta\beta$ decay in $^{76}$Ge is set at $T_{1/2}>1.8\times10^{26}$ yr at 90% C.L., which coincides with the sensitivity assuming no signal.

nucl-ex

The first search for bosonic super-WIMPs with masses up to 1 MeV/c$^2$ with GERDA

We present the first search for bosonic super-WIMPs as keV-scale dark matter candidates performed with the GERDA experiment. GERDA is a neutrinoless double-beta decay experiment which operates high-purity germanium detectors enriched in $^{76}$Ge in an ultra-low background environment at the Laboratori Nazionali del Gran Sasso (LNGS) of INFN in Italy. Searches were performed for pseudoscalar and vector particles in the mass region from 60 keV/c$^2$ to 1 MeV/c$^2$. No evidence for a dark matter signal was observed, and the most stringent constraints on the couplings of super-WIMPs with masses above 120 keV/c$^2$ have been set. As an example, at a mass of 150 keV/c$^2$ the most stringent direct limits on the dimensionless couplings of axion-like particles and dark photons to electrons of $g_{ae} < 3 \cdot 10^{-12}$ and ${\alpha'}/{\alpha} < 6.5 \cdot 10^{-24}$ at 90% credible interval, respectively, were obtained.

hep-ex

Probing Majorana neutrinos with double-$\beta$ decay

A discovery that neutrinos are not the usual Dirac but Majorana fermions, i.e. identical to their antiparticles, would be a manifestation of new physics with profound implications for particle physics and cosmology. Majorana neutrinos would generate neutrinoless double-$\beta$ ($0\nu\beta\beta$) decay, a matter-creating process without the balancing emission of antimatter. So far, 0$\nu\beta\beta$ decay has eluded detection. The GERDA collaboration searches for the $0\nu\beta\beta$ decay of $^{76}$Ge by operating bare germanium detectors in an active liquid argon shield. With a total exposure of 82.4 kg$\cdot$yr, we observe no signal and derive a lower half-life limit of T$_{1/2}$ > 0.9$\cdot$10$^{26}$ yr (90% C.L.). Our T$_{1/2}$ sensitivity assuming no signal is 1.1$\cdot$10$^{26}$ yr. Combining the latter with those from other $0{\nu}\beta\beta$ decay searches yields a sensitivity to the effective Majorana neutrino mass of 0.07 - 0.16 eV, with corresponding sensitivities to the absolute mass scale in $\beta$ decay of 0.15 - 0.44 eV, and to the cosmological relevant sum of neutrino masses of 0.46 - 1.3 eV.

hep-ex

Modeling of GERDA Phase II data

The GERmanium Detector Array (GERDA) experiment at the Gran Sasso underground laboratory (LNGS) of INFN is searching for neutrinoless double-beta ($0\nu\beta\beta$) decay of $^{76}$Ge. The technological challenge of GERDA is to operate in a "background-free" regime in the region of interest (ROI) after analysis cuts for the full 100$\,$kg$\cdot$yr target exposure of the experiment. A careful modeling and decomposition of the full-range energy spectrum is essential to predict the shape and composition of events in the ROI around $Q_{\beta\beta}$ for the $0\nu\beta\beta$ search, to extract a precise measurement of the half-life of the double-beta decay mode with neutrinos ($2\nu\beta\beta$) and in order to identify the location of residual impurities. The latter will permit future experiments to build strategies in order to further lower the background and achieve even better sensitivities. In this article the background decomposition prior to analysis cuts is presented for GERDA Phase II. The background model fit yields a flat spectrum in the ROI with a background index (BI) of $16.04^{+0.78}_{-0.85} \cdot 10^{-3}\,$cts/(kg$\cdot$keV$\cdot$yr) for the enriched BEGe data set and $14.68^{+0.47}_{-0.52} \cdot 10^{-3}\,$cts/(kg$\cdot$keV$\cdot$yr) for the enriched coaxial data set. These values are similar to the one of Gerda Phase I despite a much larger number of detectors and hence radioactive hardware components.

nucl-ex

Characterization of 30 $^{76}$Ge enriched Broad Energy Ge detectors for GERDA Phase II

The GERmanium Detector Array (GERDA) is a low background experiment located at the Laboratori Nazionali del Gran Sasso in Italy, which searches for neutrinoless double beta decay of $^{76}$Ge into $^{76}$Se+2e$^-$. GERDA has been conceived in two phases. Phase II, which started in December 2015, features several novelties including 30 new Ge detectors. These were manufactured according to the Broad Energy Germanium (BEGe) detector design that has a better background discrimination capability and energy resolution compared to formerly widely-used types. Prior to their installation, the new BEGe detectors were mounted in vacuum cryostats and characterized in detail in the HADES underground laboratory in Belgium. This paper describes the properties and the overall performance of these detectors during operation in vacuum. The characterization campaign provided not only direct input for GERDA Phase II data collection and analyses, but also allowed to study detector phenomena, detector correlations as well as to test the strength of pulse shape simulation codes.

physics.ins-det

Limits on uranium and thorium bulk content in GERDA Phase I detectors

Internal contaminations of $^{238}$U, $^{235}$U and $^{232}$Th in the bulk of high purity germanium detectors are potential backgrounds for experiments searching for neutrinoless double beta decay of $^{76}$Ge. The data from GERDA Phase~I have been analyzed for alpha events from the decay chain of these contaminations by looking for full decay chains and for time correlations between successive decays in the same detector. No candidate events for a full chain have been found. Upper limits on the activities in the range of a few nBq/kg for $^{226}$Ra, $^{227}$Ac and $^{228}$Th, the long-lived daughter nuclides of $^{238}$U, $^{235}$U and $^{232}$Th, respectively, have been derived. With these upper limits a background index in the energy region of interest from $^{226}$Ra and $^{228}$Th contamination is estimated which satisfies the prerequisites of a future ton scale germanium double beta decay experiment.