Searcharxiv⌕ Search

arXiv subjects

Gabriel Couture

Publications and source records attributed to Gabriel Couture.

2 recordsLinked to original sources

LUCQUE: A lung cancer screening dataset from Québec for reliable AI evaluation

BACKGROUND: AI-based tools are expected to play a key role in lung cancer screening (LCS). The evaluation of these tools often relied on private datasets or fragmented public datasets with inconsistent availability of clinical data and expert nodule annotations. This has hindered reproducibility, comparability, and independent assessment of AI tools. To address these gaps, we present LUCQUE, a novel, large, comprehensively annotated dataset derived from LDCT lung cancer screening in Québec, which is accessible for reliable AI evaluation. METHODS: LUCQUE was curated and is hosted on PARADIM, a digital infrastructure supporting DICOM data de-identification, annotation, long-term storage and analysis. LDCT scans and clinical information were combined to a curated collection and complemented by voxel-level, expert-derived pulmonary nodule and cyst segmentations, and Lung-RADS-based lesion characteristics. Key dataset characteristics and statistics were reported, including participant demographics, imaging parameters, radiological findings, and segmented lesion characteristics. Dataset analyses were conducted according to PARADIM's model-to-data approach, in which user code is executed on the platform such that data remains on premise. RESULTS: LUCQUE currently comprises 1,678 LDCT baseline studies from 1,678 participants. Most studies were classified as Lung-RADS 2. A total of 1,776 pulmonary nodules and 60 cysts were annotated, with a median (interquartile range) volume of $89\,(56,\,159)\,\mathrm{mm}^3$ and $1,384\,(589,\,3793)\,\mathrm{mm}^3$ respectively. CONCLUSIONS: Compared to publicly available LCS datasets, LUCQUE currently represents the largest accessible annotated real-world LCS dataset. Access to LUCQUE is provided via a model-to-data approach, enabling privacy-preserving, reproducible, and independent real-world evaluation of AI tools in LCS.

cs.DB↗

On the use of machine learning methods for mPSD calibration in HDR brachytherapy

Purpose: We sought to evaluate the feasibility of using machine learning algorithms for multipoint plastic scintillator detector calibration in high-dose-rate brachytherapy. Methods: The dosimetry system consisted of an optimized 1-mm-core mPSD and a compact assembly of photomultiplier tubes coupled with dichroic mirrors and filters. An $^{192}$Ir source was remotely controlled and sent to various positions in a homemade PMMA holder. Dose measurements covering a range of 0.5 to 12 cm of source displacement were carried out according to TG-43 recommendations. Individual scintillator doses were decoupled using a linear regression model, a random forest estimator, and artificial neural network algorithms. The performance of the different algorithms was evaluated using different sample sizes and distances to the source for the mPSD system calibration. Results: The decoupling methods' deviations from the expected TG-43 dose generally remained below 20%. However, the dose prediction with the three algorithms was accurate to within 7% relative to the dose predicted by the TG-43 formalism for measurements performed in the same range of distances used for calibration. The performance random forest was compromised when the predictions were done beyond the range of distances used for calibration. The dose prediction by the linear regression was less influenced by the calibration conditions than random forest, but with more significant deviations. The number of available measurements for training purposes influenced the random forest and neural network models the most. Their accuracy tended to converge toward deviation values close to 1% from a number of dwell positions greater than 100. Conclusions: In performing HDR brachytherapy dose measurements with an optimized mPSD system, ML algorithms are good alternatives for precise dose reporting and treatment assessment.

physics.med-ph↗