SearcharxivSearch

arXiv subjects

Gabriel Sanca

Publications and source records attributed to Gabriel Sanca.

5 recordsLinked to original sources

Front End Amplifiers for Simultaneous Dual Readout of SiPM Sensors

In this work, we present two fully open Analog Front End (AFE) designs for the simultaneous readout of the standard and fast outputs of ONSemi MicroFC-10035 Silicon Photomultipliers and report their main figure-of-merit parameters. The standard output AFE has a 1 p.e. amplitude of $(394 \pm 1)$ mV, which results in a Signal-to-Noise ratio of 30 dB. In addition, the fast AFE has a rise time of $(1.3\pm 0.1)$ ns and a median electronic jitter of $34^{+7}_{-5}$ ps, resulting in an excellent timing performance. Using these amplifiers for simultaneous dual readout, we demonstrate a proof-of-concept application, in which fast output timing information is used to suppress correlated noise events or pileup events present in the standard output charge measurements. This suppression results in a reduction of non-prompt correlated noise (delayed crosstalks and afterpulses) in dark conditions and an increase up to $\sim$14 in single photon discrimination under a continuous incident photon rate of 7.8 MHz/mm$^2$. These results show that dual SiPM readout provides a practical way to remove correlated noise or pileup contamination in standard output charge measurements on an event-by-event basis.

physics.ins-det

Total Ionizing Dose Measurements in Small Satellites in LEO using LabOSat-01

LabOSat-01 is a payload designed to perform characterization experiments on electronic devices in hostile environments. Both Commercial-Off-The-Shelf components and custom nano and micro devices were studied in the last decade with this platform. The Total Ionizing Dose (TID) received by small satellites in Low Earth Orbit was measured with LabOSat-01 using p-MOSFET COTS and the results are presented in this work. Measurements were performed on two satellite missions, each totalling 1100 days, launched three years apart. Dosimeters were integrated in different satellite positions, with different shielding, and the measured TID after 1100 days ranged from 5 Gy to 19 Gy.

physics.space-ph

Design and characterization of a fast output amplifier for Silicon Photomultipliers

A voltage amplifier, based on the BFU500XRR NPN transistor in a common-emitter configuration, was developed for the readout of the fast output of an ONSEMI MicroFC-10035 Silicon Photomultiplier (SiPM). This amplifier was tested and characterized under dark and illuminated SiPM conditions. For the design presented in this work, a Gain of $(20.0 \pm 0.7)$ dB and a rise time of $(768 \pm 10)$ ps were achieved for one amplifier stage and a Gain of $(38.3 \pm 0.7)$ dB and rise time of $(1155 \pm 16)$ ps was achieved for two cascaded stages. In addition, the linearity of both topologies was verified and the measured Signal-to-Noise Ratio (SNR) was ($21.9 \pm 0.4$) dB and ($18.8 \pm 0.5$) dB for the one-stage and two-stage amplifiers, respectively. This design provides a cheap and scalable (weight and size) alternative to other fast output amplifiers that are used when operating SiPMs fast outputs. These characteristics make this design ideal for space applications.

physics.ins-det

Characterization of the SiPiC Payload for Photon Detection from Space

In this work, the SiPiC (SiPM Pinhole Camera) Payload is detailed. This Payload will potentially be integrated in two distinct satellite missions, which will operate in Low Earth Orbit (LEO) and in a High Altitude Orbit (HAO), respectively. The SiPiC Payload has two main objectives: to test Silicon Photomultipliers (SiPMs) as visible light sensors for stimuli originating from Earth; and to perform an in-orbit validation (IOV) of the new generation of PC104-compliant LabOSat subsystems. Preliminary measurements of the Payload's operational capabilities are performed and discussed. These include payload telemetry analysis, Field-of-View tests for the Earth imaging SiPM subsystem, and performance evaluations of the new LabOSat modules for known devices under test. The measured Angular Field of View (AFOV) for the light gathering SiPM subsystem is $(6.2 \pm 0.5)^{\mathrm{o}}$, which results in a FOV of $(4333 \pm 350)$ km on the surface of the Earth at 40000 km altitude and $(54 \pm 5)$ km at 500 km altitude.

physics.ins-det

Characterization of SiPM Performance in a Small Satellite in Low Earth Orbit using LabOSat-01

In this work, the performance of SensL MicroFC-60035 SiPM devices was studied during a 1460-day mission in Low Earth Orbit (LEO) using the LabOSat-01 characterization payload. Two of these platforms, carrying two SiPMs each, were integrated into the ÑuSat-7 satellite (COSPAR-ID: 2020-003B). Analysis revealed that these SiPMs experienced an increase in dark current over time due to damage from trapped and solar proton radiation. The total ionizing dose received by the payload and the SiPMs was measured using p-MOSFET dosimeters, with a resulting value of 5 Gy, or a 1 MeV neutron equivalent fluence of $ϕ_n = 5 \cdot 10^9$ n/cm$^2$. The dark current was observed to increase up to 500 times. Parameters such as Gain and Photon Detection Efficiency remained unchanged throughout the mission. These findings align with previous performance reports involving different SiPMs irradiated with various particles and energies.

physics.ins-det