SearcharxivSearch

arXiv subjects

Gaetano Gerardi

Publications and source records attributed to Gaetano Gerardi.

3 recordsLinked to original sources

Kaonic Copper and Fluorine Absolute Yields Measurement with a CZT-based Detection System at DA$\Phi$NE

\noindent In this work, new measurements of absolute X-ray yields for several transitions in kaonic copper and, for the first time, in kaonic fluorine are reported. The data were collected by the SIDDHARTA-2 collaboration at the DA$\Phi$NE collider using a novel room-temperature Cadmium Zinc Telluride (CZT) detection system. Detection efficiencies were evaluated through a dedicated Geant4 Monte Carlo simulation of the full experimental setup, enabling the extraction of absolute yields per stopped kaon. \noindent The measured yields exhibit a systematic dependence on the principal quantum number, reflecting the interplay between radiative transitions, Auger de-excitation, and strong-interaction-induced nuclear capture. In kaonic fluorine, a suppression of the 4$\to$3 transition yield relative to higher-n transitions is observed, providing evidence for the onset of strong-interaction effects already at the $n=4$ level. From this behaviour, a conservative lower limit on the corresponding strong-interaction width is derived. \noindent These results provide new quantitative constraints for cascade models of exotic atoms and extend experimental access to intermediate atomic levels where strong-interaction effects are not directly observable via level shifts and widths. They also establish CZT-based detection as a powerful and versatile approach for high-resolution X-ray spectroscopy of kaonic atoms in collider environments.

nucl-ex

CZT Detectors for kaonic atoms spectroscopy

Cadmium zinc telluride (CZT) detectors offer excellent room-temperature energy resolution, making them well suited for X- and $\gamma$-ray spectroscopy in challenging environments. Within the SIDDHARTA-2 program at the DA$\Phi$NE collider, a new CZT-based detection system has been developed to enable precision measurements of kaonic atom transitions in the intermediate mass range. In this work, we report the results of a calibration campaign performed with the collider operating, aimed at assessing the detector performance. A dedicated setup, including an array of quasi-hemispherical CZT sensors and a $^{152}$Eu source, was used to characterize the spectral response. The reconstructed emission lines were fitted with a model accounting for Gaussian response and incomplete charge recollection tails, and the detector linearity was evaluated by comparing the measured peak positions with their nominal energies. The results demonstrate that the CZT detector exhibits excellent linearity and stable operation with the collider on, confirming its suitability for future kaonic-atom spectroscopy at DA$\Phi$NE.

physics.ins-det

Time-based Selection of Kaonic Atom X-ray Events with Quasi-Hemispherical CZT Detectors at the DAFNE collider

This work presents the results of a time-based event selection for searching X-ray signals from kaonic atom X-ray transition using a single quasi-hemispherical Cadmium-Zinc-Telluride (CZT) detector at the DA$\Phi$NE collider. To mitigate the high background level in the measured X-ray spectrum, a dedicated event selection strategy was developed, exploiting the precise timing correlation between e+e- collisions and detector signals. This approach enabled, for the first time, the observation of two characteristic X-ray transitions from kaonic aluminum atoms using a CZT detector: for the 5-4 transition at 50~keV, 362~$\pm$~41~(stat.)~$\pm$~20~(sys.) signal events over 1698~$\pm$~197~(stat.)~$\pm$~25~(sys.) background events in 5$\sigma$ were observed, with a resolution of 9.2\%~FWHM; for the 4-3 transition at 106~keV, 295~$\pm$~50~(stat.)~$\pm$~20~(sys.) signal events over 2939~$\pm$~500~(stat.)~$\pm$~16~(sys.) background events in 5$\sigma$ were measured, with a resolution of 6.6 ~FWHM. A strong background suppression of approximately 95\% of the triggered data was achieved through this time-based selection. The demonstrated timing capability of the CZT detector proved highly effective in isolating time-correlated events within an 80 ns window, setting an important benchmark for the application of these semiconductors in timing-based X-ray spectroscopy. These results highlight the potential of CZT-based detection systems for future precision measurements in high-radiation environments, paving the way for compact, room-temperature X-ray and $\gamma$-ray spectrometers in fundamental physics and beyond.

physics.ins-det