Searcharxiv⌕ Search

arXiv subjects

Gaia Dellepiane

Publications and source records attributed to Gaia Dellepiane.

6 recordsLinked to original sources

Development of a Proton Therapy Research Beamline with FLASH and Minibeam Capabilities at the 18 MeV Bern Medical Cyclotron

Advanced radiotherapy approaches such as FLASH irradiation and spatially fractionated radiotherapy (SFRT) show potential to improve the therapeutic ratio, yet their biological mechanisms and optimal delivery parameters remain uncertain. Progress requires accessible proton research platforms with flexible temporal and spatial dose delivery. We report on the adaptation of the Beam Transfer Line (BTL) of the Bern Medical Cyclotron (BMC) for radiobiology research with FLASH and proton minibeam capabilities. The BMC is optimized for the production of radionuclides for medical imaging, and is able to extract currents up to 150 $ \mathrm{μA}$. The 18 MeV proton beam was passively shaped using collimators, scattering foils, and extended drift space to generate irradiation fields. A dosimetric framework was implemented using an in-beam ionization chamber and radiochromic film with LET-dependent corrections. Beam uniformity and SFRT profiles with various grid spacings were evaluated at realistic target distances. The developed beamline enables stable delivery under controlled conditions in both conventional and FLASH regimes, spanning dose rates from 0.01 to 100 Gy/s. Dose uniformity within a 20 mm radius was below 8\%. Film measurements confirmed the need for LET-dependent corrections and indicated that quantitative dosimetry in in-vitro setups is achievable with appropriate LET corrections. The low proton energy (15.54(12) MeV extracted into air, 8.14(28) MeV delivered to cells in flask) facilitates compact SFRT implementation with well-resolved minibeams. The adapted BMC provides a flexible and accessible platform for systematic pre-clinical proton radiobiology studies under varied dose-rate and spatial delivery conditions. This supports optimization of emerging modalities such as proton FLASH and SFRT and helps bridge accelerator technology and radiobiology.

physics.med-ph↗

Non-Destructive Beam Monitoring via Secondary Radiation Detection with Ce-Doped Silica Fibers

Non-destructive beam diagnostics are essential for low-energy medical cyclotrons, where even thin interceptive devices can severely degrade beam quality. We investigate an external fiber monitor (EFM) based on Ce-doped silica scintillating fibers that detects secondary radiation generated at existing beamline components of the 18 MeV Bern Medical Cyclotron beam transfer line (BTL). Three use cases were studied: (i) beam intensity monitoring around an electrically isolated, water-cooled beam dump; (ii) beam-loss monitoring around a 10 mm collimator under varying the beam focusing; and (iii) by steering a 6.5 mm $\times$ 6.5 mm beam spot on a beam dump. For case (i), the summed EFM signal exhibits a linear dependence on the current on target over nearly three orders of magnitude. In case (ii), a normalized EFM-based beam-loss proxy scales monotonically with an electrical loss proxy across several focusing settings. Furthermore, opposing-fiber signal ratios provide decoupled, monotonic sensitivity to horizontal and vertical beam displacements.

physics.ins-det↗

Beam Energy Measurement using a Bayesian Approach with the Stacked Foil Method

We present a practical method to measure the energy of proton beams at a medical cyclotron using the stacked foil technique in combination with a Bayesian inference method. By measuring the $^{48}$V activity induced in a stack of irradiated titanium foils, the proton energy can be inferred without relying on direct current or charge measurements, making the method suitable even for low-vacuum environments or air-exposed setups. This technique is further extended to configurations where the beam energy is degraded to levels around 8 MeV. A Bayesian fit of the measured activity profile allows not only for a robust energy estimation but also for a consistent treatment of uncertainties and nuisance parameters. Monte Carlo simulations are employed to validate the underlying assumptions, including the impact of energy dispersion or cross-section uncertainties. Our results demonstrate that this method provides accurate beam energy measurements across several typical experimental setups used at the Bern Medical Cyclotron. Additionally, we evaluate the sensitivity of the method to the choice of nuclear cross-section data and assess how the number of foils in the stack affects the uncertainty in the inferred beam energy.

physics.acc-ph↗

Quality assurance and reporting for FLASH clinical trials:the experience of the FEATHER trial

Research on ultra-high dose rate (UHDR) radiation therapy has indicated its potential to spare normal tissue while maintaining equivalent tumor control compared to conventional treatments. First clinical trials are underway. The randomized phase II/III FEATHER clinical trial at the Paul Scherrer Institute in collaboration with the University of Zurich Animal Hospital is one of the first curative domestic animal trials to be attempted, and it is designed to provide a good example for human trials. However, the lack of standardized quality assurance (QA) guidelines for FLASH clinical trials presents a significant challenge in trial design. This work aims to demonstrate the development and testing of QA and reporting procedures implemented in the FEATHER clinical trial. We have expanded the clinical QA program to include UHDR-specific QA and additional patient-specific QA. Furthermore, we have modified the monitor readout to enable time-resolved measurements, allowing delivery log files to be used for dose and dose rate recalculations. Finally, we developed a reporting strategy encompassing relevant parameters for retrospective studies. We evaluated our QA and reporting procedures with simulated treatments. This testing confirmed that our QA procedures effectively ensure the correct and safe delivery of the planned dose. Additionally, we demonstrated that we could reconstruct the delivered dose and dose rate using the delivery log files. We developed and used in practice a comprehensive QA and reporting protocol for a FLASH clinical trial at the Paul Scherrer Institute. This work aims to establish guidelines and standardize reporting practices for future advancements in the FLASH-RT field.

physics.med-ph↗

Methodology for measuring photonuclear reaction cross sections with an electron accelerator based on Bayesian analysis

Accurate measurements of photonuclear reaction cross sections are crucial for a number of applications, including radiation shielding design, absorbed dose calculations, reactor physics and engineering, nuclear safeguard and inspection, astrophysics, and nuclear medicine. Primarily motivated by the study of the production of selected radionuclides with high-energy photon beams (mainly 225Ac, 47Sc, and 67Cu), we have established a methodology for the measurement of photonuclear reaction cross sections with the microtron accelerator available at the Swiss Federal Institute of Metrology (METAS). The proposed methodology is based on the measurement of the produced activity with a High Purity Germanium (HPGe) spectrometer and on the knowledge of the photon fluence spectrum through Monte Carlo simulations. The data analysis is performed by applying a Bayesian fitting procedure to the experimental data and by assuming a functional trend of the cross section, in our case a Breit-Wigner function. We validated the entire methodology by measuring a well-established photonuclear cross section, namely the 197Au(γ,n)196Au reaction. The results are consistent with those reported in the literature.

nucl-ex↗

A facility for radiation hardness studies based on a medical cyclotron

The development of instrumentation for operation in high-radiation environments represents a challenge in various research fields, particularly in particle physics experiments and space missions, and drives an ever-increasing demand for irradiation facilities dedicated to radiation hardness studies. Depending on the application, different needs arise in terms of particle type, energy and dose rate. In this article, we present a versatile installation based on a medical cyclotron located at the Bern University Hospital (Inselspital), which is used as a controlled 18-MeV proton source. This accelerator is used for daily production of medical radioisotopes, as well as for multidisciplinary research, thanks to a 6.5-meter long beam transfer line that terminates in an independent bunker, dedicated only to scientific activities. The facility offers a wide range of proton fluxes, due to an adjustable beam current from approximately 10 pA to the micro-ampere range, together with a series of steering and focusing magnets along the beamline that allow for the beam spot to be focused down to a few mm^2. The beamline can be instrumented with a variety of beam monitoring detectors, collimators, and beam current measurement devices to precisely control the irradiation conditions. The facility also hosts a well equipped laboratory dedicated to the characterisation of samples after irradiation. An experimental validation of the irradiation setup, with proton fluxes ranging from $5\times10^9$ cm$^{-2}$s$^{-1}$ to $4\times10^{11}$ cm$^{-2}$s$^{-1}$, is reported in this article.

physics.ins-det↗