SearcharxivSearch

arXiv subjects

Gar-Wing Truong

Publications and source records attributed to Gar-Wing Truong.

13 recordsLinked to original sources

Ion-Beam-Sputtered Mid-Infrared Coatings for Hybrid Supermirrors

We report on the development of low-loss ion-beam-sputtered (IBS) mid-infrared coatings for hybrid supermirrors. Two highly reflective designs were realized: HR1, a 4-period a-Si/SiO$_2$ DBR with an Al$_2$O$_3$ bonding layer, and HR2, a 6-period a-Si/Ta$_2$O$_5$ DBR with an a-Si terminating layer for bonding. Combined with a GaAs/AlGaAs crystalline mirror, HR2-based hybrids yielded a total loss of 9.3 ppm and excess loss of 6.8 ppm at 4.45 $\mu$m, with cavity finesse up to 396000. For the first time, we used IBS-deposited a-Si directly as a bonding layer, verified its sub-angstrom roughness, and demonstrated excellent performance. This establishes a clear path toward scalable coatings for longer mid-infrared wavelengths, building on prior results in Nat. Commun. 14, 7846 (2023).

physics.optics

Simultaneous Measurement of Mid-Infrared Refractive Indices in Thin-Film Heterostructures: Methodology and Results for GaAs/AlGaAs

We present our results for simultaneous measurement of the refractive indices of gallium arsenide (GaAs) and aluminum gallium arsenide (Al$_\mathrm{x}$Ga$_\mathrm{1-x}$As) from $2.0$ to $7.1\,\mathrm{μm}$ ($5000$ to $1400\,\mathrm{cm^{-1}}$). We obtain these values from a monocrystalline superlattice Bragg mirror of excellent purity (background doping $\leq 1 \times 10^{-14}\,\mathrm{cm^{-3}}$), grown via molecular beam epitaxy. To recover the refractive indices over such a broad wavelength range, we fit a dispersion model for each material. In a novel combination of well-established methods, we measure both a photometrically accurate transmittance spectrum of the Bragg mirror via Fourier-transform infrared spectrometry and the individual physical layer thicknesses of the structure via scanning electron microscopy. To infer the uncertainty of the refractive index values, we estimate relevant measurement uncertainties and propagate them via a Monte-Carlo method. This highly-adaptable approach conclusively yields propagated relative uncertainties on the order of $10^{-4}$ over the measured spectral range for both GaAs and Al$_{0.929}$Ga$_{0.071}$As. The fitted model can also approximate the refractive index for MBE-grown Al$_\mathrm{x}$Ga$_\mathrm{1-x}$As for $0\leq x \leq 1$. Both these updated values and the measurement approach will be essential in the design, fabrication, and characterization of next-generation active and passive optical devices in a spectral region that is of high interest in many fields, e.g., laser design and cavity-enhanced spectroscopy in the mid-infrared spectral region.

physics.optics

Precise Measurement of Refractive Indices in Thin Film Heterostructures

We present a robust, precise, and accurate method to simultaneously measure the refractive indices of two transparent materials within an interference coating. This is achieved by measuring both a photometrically accurate transmittance spectrum and the as-grown individual layer thicknesses of a thin-film multilayer structure. These measurements are used for a TMM-based curve-fitting routine which extracts the refractive indices and their measurement uncertainties via a Monte-Carlo-type error propagation. We demonstrate the performance of this approach by experimentally measuring the refractive indices of both, GaAs and Al$_{0.929}$Ga$_{0.071}$As, as present in an epitaxial distributed Bragg reflector. A variety of devices can be used to obtain the transmittance spectrum (e.g., FTIR, grating-based spectrophotometer) and layer thicknesses (e.g., SEM, TEM, AFM), the discussed approach is readily adaptable to virtually any wavelength region and many transparent material combinations of interest. The subsequent model-fitting approach yields refractive index values with $10^{-4}$-level uncertainty for both materials.

physics.optics

Tunable dual-comb from an all-polarization-maintaining single-cavity dual-color Yb:fiber laser

We demonstrate dual-comb generation from an all-polarization-maintaining dual-color ytterbium (Yb) fiber laser. Two pulse trains with center wavelengths at 1030 nm and 1060 nm respectively are generated within the same laser cavity with a repetition rate around 77 MHz. Dual-color operation is induced using a tunable mechanical spectral filter, which cuts the gain spectrum into two spectral regions that can be independently mode-locked. Spectral overlap of the two pulse trains is achieved outside the laser cavity by amplifying the 1030-nm pulses and broadening them in a nonlinear fiber. Spatially overlapping the two arms on a simple photodiode then generates a down-converted radio frequency comb. The difference in repetition rates between the two pulse trains and hence the line spacing of the down-converted comb can easily be tuned in this setup. This feature allows for a flexible adjustment of the tradeoff between non-aliasing bandwidth vs. measurement time in spectroscopy applications. Furthermore, we show that by fine-tuning the center-wavelengths of the two pulse trains, we are able to shift the down-converted frequency comb along the radio-frequency axis. The usability of this dual-comb setup is demonstrated by measuring the transmission of two different etalons while the laser is completely free-running.

physics.optics

Near-Infrared Scanning Cavity Ringdown for Optical Loss Characterization of Supermirrors

A cavity ringdown system for probing the spatial variation of optical loss across high-reflectivity mirrors is described. This system is employed to examine substrate-transferred crystalline supermirrors and quantify the effect of manufacturing process imperfections. Excellent agreement is observed between the ringdown-generated spatial measurements and differential interference contrast microscopy images. A 2 mm diameter ringdown scan in the center of a crystalline supermirror reveals highly uniform coating properties with excess loss variations below 1 ppm.

physics.ins-det

Continuous regional trace gas source attribution using a field-deployed dual frequency comb spectrometer

Identification and quantification of trace gas sources is a major challenge for understanding and regulating air quality and greenhouse gas emissions. Current approaches either provide continuous but localized monitoring, or quasi-instantaneous 'snapshot-in-time' regional monitoring. There is a need for emissions detection that provides both continuous and regional coverage, because sources and sinks can be episodic and spatially variable. We field deploy a dual frequency comb laser spectrometer for the first time, enabling an observing system that provides continuous detection of trace gas sources over multiple-square-kilometer regions. Field tests simulating methane emissions from oil and gas production demonstrate detection and quantification of a 1.6 g min^-1 source (approximate emissions from a small pneumatic valve) from a distance of 1 km, and the ability to discern two leaks among a field of many potential sources. The technology achieves the goal of detecting, quantifying, and attributing emissions sources continuously through time, over large areas, and at emissions rates ~1000x lower than current regional approaches. It therefore provides a useful tool for monitoring and mitigating undesirable sources and closes a major information gap in the atmospheric sciences.

physics.ao-ph

Accurate frequency referencing for fieldable dual-comb spectroscopy

A fieldable dual-comb spectrometer is described based on a "bootstrapped" frequency referencing scheme in which short-term optical phase coherence between combs is attained by referencing each to a free-running diode laser, whilst high frequency resolution and long-term accuracy is derived from a stable quartz oscillator. This fieldable dual-comb spectrometer was used to measure spectra with full comb-tooth resolution spanning from 140 THz (2.14 um, 4670 cm^-1) to 184 THz (1.63 um, 6140 cm^-1) in the near infrared with a frequency sampling of 200 MHz (0.0067 cm^-1), ~ 120 kHz frequency resolution, and ~ 1 MHz frequency accuracy. High resolution spectra of water and carbon dioxide transitions at 1.77 um, 1.96 um and 2.06 um show that the molecular transmission acquired with this fieldable system did not deviate from those measured with a laboratory-based system (referenced to a maser and cavity-stabilized laser) to within 5.6x10^-4. Additionally, the fieldable system optimized for carbon dioxide quantification at 1.60 um, demonstrated a sensitivity of 2.8 ppm-km at 1 s integration time, improving to 0.10 ppm-km at 13 minutes of integration time.

physics.ins-det

Quantum-Limited Spectroscopy

Spectroscopy has an illustrious history delivering serendipitous discoveries and providing a stringent testbed for new physical predictions, including applications from trace materials detection, to understanding the atmospheres of stars and planets, and even constraining cosmological models. Reaching fundamental-noise limits permits optimal extraction of spectroscopic information from an absorption measurement. Here we demonstrate a quantum-limited spectrometer that delivers high-precision measurements of the absorption lineshape. These measurements yield a ten-fold improvement in the accuracy of the excited-state (6P$_{1/2}$) hyperfine splitting in Cs, and reveals a breakdown in the well-known Voigt spectral profile. We develop a theoretical model that accounts for this breakdown, explaining the observations to within the shot-noise limit. Our model enables us to infer the thermal velocity-dispersion of the Cs vapour with an uncertainty of 35ppm within an hour. This allows us to determine a value for Boltzmann's constant with a precision of 6ppm, and an uncertainty of 71ppm.

physics.atom-ph

Linewidth of collimated wavelength-converted emission in Rb vapours

We present a study of the spectral linewidth of collimated blue light (CBL) that results from wave mixing of low-power cw laser radiation at 780 nm and 776 nm and an internally-generated mid-IR field at 5.23 um in Rb vapour. Using a high-finesse Fabry-Perot interferometer the spectral width of the CBL is found to be less than 1.3 MHz for a wide range of experimental conditions. We demonstrate that the CBL linewidth is mainly limited by the temporal coherence of the applied laser fields rather than the atom-light interaction itself. Results obtained with frequency modulated laser light allow an upper limit of several hundred kHz to be set for the linewidth of the collimated mid-IR radiation at 5.23 um, which has not been directly detected.

physics.atom-ph

Frequency evaluation of collimated blue light generated by wave mixing in Rb vapour

An evaluation of the absolute frequency and tunability of collimated blue light (CBL) generated in warm Rb vapour excited by low-power cw laser radiation at 780 nm and 776 nm, has been performed using a Fabry-Perot interferometer and a blue diode laser. For the conditions of our experiments the CBL tuning range is more than 100 MHz around the resonant frequency of the 85Rb 5S1/2 (F=3) to 6P3/2 (F'=4) transition. A simple technique for stabilizing the power and frequency of the CBL to within a few percent and 10 MHz, respectively, is suggested and demonstrated.

physics.atom-ph

Spectral Lineshape Measurements with Shot-Noise Limited Accuracy

Spectroscopy has played the key role in revealing, and thereby understanding, the structure of atoms and molecules. A central drive in this field is the pursuit of higher precision and accuracy so that ever more subtle effects might be discovered. Here, we report on laser absorption spectroscopy that operates at the conventional quantum limit imposed by photon shot-noise. Furthermore, we achieve this limit without compromising the accuracy of the measurement. We demonstrate these properties by recording an absorption profile of cesium vapor at the 2 parts-per-million level. The extremely high signal-to-noise ratio allows us to directly observe the homogeneous lineshape component of the spectral profile, even while in the presence of Doppler broadening that is a factor of 100 times wider. We can do this because we can precisely measure the spectral profile at a frequency detuning more than 200 natural linewidths from the line center. We use the power of this tool to demonstrate direct measurements of a low-intensity optically-induced broadening process that is quite distinct from the well-known power broadening phenomenon.

physics.optics

Power Dependent Lineshape Corrections for Quantitative Spectroscopy

The Voigt profile - a convolution of a Gaussian and a Lorentzian - accurately describes the absorption lines of atomic and molecular gases at low probe powers. Fitting such to experimental spectra yields both the Lorentzian natural linewidth and the Gaussian Doppler broadening. However, as the probe power increases saturation effects introduce spurious power dependence into the fitted Doppler width. Using a simple atomic model, we calculate power-dependent corrections to the Voigt profile, which are parametrized by the Gaussian Doppler width, the Lorentzian natural linewidth, and the optical depth. We show numerically and experimentally that including the correction term substantially reduces the spurious power dependence in the fitted Gaussian width.

physics.atom-ph

Quantitative atomic spectroscopy for primary thermometry

Quantitative spectroscopy has been used to measure accurately the Doppler-broadening of atomic transitions in $^{85}$Rb vapor. By using a conventional platinum resistance thermometer and the Doppler thermometry technique, we were able to determine $k_B$ with a relative uncertainty of $4.1\times 10^{-4}$, and with a deviation of $2.7\times 10^{-4}$ from the expected value. Our experiment, using an effusive vapour, departs significantly from other Doppler-broadened thermometry (DBT) techniques, which rely on weakly absorbing molecules in a diffusive regime. In these circumstances, very different systematic effects such as magnetic sensitivity and optical pumping are dominant. Using the model developed recently by Stace and Luiten, we estimate the perturbation due to optical pumping of the measured $k_B$ value was less than $4\times 10^{-6}$. The effects of optical pumping on atomic and molecular DBT experiments is mapped over a wide range of beam size and saturation intensity, indicating possible avenues for improvement. We also compare the line-broadening mechanisms, windows of operation and detection limits of some recent DBT experiments.

physics.optics