SearcharxivSearch

arXiv subjects

Gary Centers

Publications and source records attributed to Gary Centers.

3 recordsLinked to original sources

Search for Axionlike Dark Matter Using Liquid-State Nuclear Magnetic Resonance

We search for dark matter in the form of axionlike particles (ALPs) in the mass range $5.576741 \,\mathrm{neV/c^2}$ - $5.577733\,\mathrm{neV/c^2}$ by probing their possible coupling to fermion spins through the ALP field gradient. This is achieved by performing proton nuclear magnetic resonance spectroscopy on a sample of methanol as a technical demonstration of the Cosmic Axion Spin Precession Experiment Gradient (CASPEr-Gradient) Low-Field apparatus. Searching for spin-coupled ALP dark matter in this mass range with associated Compton frequencies in a 240 Hz window centered at 1.348570 MHz resulted in a sensitivity to the ALP-proton coupling constant of $g_{\mathrm{ap}} \approx 3 \times 10^{-2}\,\mathrm{GeV}^{-1}$. This narrow-bandwidth search serves as a proof-of-principle and a commissioning measurement, validating our methodology and demonstrating the experiment's capabilities. CASPEr-Gradient Low-Field will probe the mass range from $4.1\,\mathrm{\peV/c^2}$ to $17\,\mathrm{\neV/c^2}$ with hyperpolarized samples to boost the sensitivity beyond the astronomical limits.

hep-ex

The Cosmic Axion Spin Precession Experiment (CASPEr): a dark-matter search with nuclear magnetic resonance

The Cosmic Axion Spin Precession Experiment (CASPEr) is a nuclear magnetic resonance experiment (NMR) seeking to detect axion and axion-like particles which could make up the dark matter present in the universe. We review the predicted couplings of axions and axion-like particles with baryonic matter that enable their detection via NMR. We then describe two measurement schemes being implemented in CASPEr. The first method, presented in the original CASPEr proposal, consists of a resonant search via continuous-wave NMR spectroscopy. This method offers the highest sensitivity for frequencies ranging from a few Hz to hundreds of MHz, corresponding to masses $ m_{\rm a} \sim 10^{-14}$--$10^{-6}$ eV. Sub-Hz frequencies are typically difficult to probe with NMR due to the diminishing sensitivity of magnetometers in this region. To circumvent this limitation, we suggest new detection and data processing modalities. We describe a non-resonant frequency-modulation detection scheme, enabling searches from mHz to Hz frequencies ($m_{\rm a} \sim 10^{-17}$--$10^{-14} $ eV), extending the detection bandwidth by three decades.

physics.ins-det

Application of Spin-Exchange Relaxation-Free Magnetometry to the Cosmic Axion Spin Precession Experiment

The Cosmic Axion Spin Precession Experiment (CASPEr) seeks to measure oscillating torques on nuclear spins caused by axion or axion-like-particle (ALP) dark matter via nuclear magnetic resonance (NMR) techniques. A sample spin-polarized along a leading magnetic field experiences a resonance when the Larmor frequency matches the axion/ALP Compton frequency, generating precessing transverse nuclear magnetization. Here we demonstrate a Spin-Exchange Relaxation-Free (SERF) magnetometer with sensitivity $\approx 1~{\rm fT/\sqrt{Hz}}$ and an effective sensing volume of 0.1 $\rm{cm^3}$ that may be useful for NMR detection in CASPEr. A potential drawback of SERF-magnetometer-based NMR detection is the SERF's limited dynamic range. Use of a magnetic flux transformer to suppress the leading magnetic field is considered as a potential method to expand the SERF's dynamic range in order to probe higher axion/ALP Compton frequencies.

physics.atom-ph