Searcharxiv⌕ Search

arXiv subjects

Gary J. R. Cook

Publications and source records attributed to Gary J. R. Cook.

3 recordsLinked to original sources

Kinematic Total-Body PET Video Reconstruction via Hierarchical List-Mode EM and Validation-Adaptive Space-Time Regularisation

Kinematic PET is introduced as an imaging task focused on visualisation of early radiotracer delivery and rapid multi-organ motion without gating. The proposed kinematic video reconstruction method uses 33-ms frames (~30 frames per second), initialised with 3D expectation maximisation (EM) time of flight (TOF) list-mode reconstruction, followed by cycles of a 2-stage update. These 2 stages are i) a hierarchical EM (HEM) update using multiple temporal pooling levels, and ii) a validation-adaptive space-time (VAST) regularisation update. HEM combines frame-specific EM corrections with corrections estimated from higher-count temporal blocks, slowing noise amplification for the ultrashort frames. VAST mixes each 3D target patch in a frame with source patches sampled nearby in space and time. It selects the candidate that best matches the mean of the corresponding patches in the two adjacent frames, with the unchanged patch also eligible. Optional temporal block sum correction uses the initial EM temporal sum as a reference to reduce loss of spatial detail. HEM+VAST was evaluated with a dynamic digital phantom, and demonstrated on human FDG data acquired on a Siemens Biograph Vision Quadra (28 - 58 s post-injection). At a background spatial coefficient of variation of 10%, the temporal full width at half maximum of the fastest phantom bolus was 151 ms with HEM+VAST, compared with 86 ms for the ground truth. The video frame rate FDG images reveal vascular and organ detail, radiotracer bolus passage and respiration-related multi-organ motion. Kinematic PET could complement conventional dynamic PET by supporting the development of image-derived physiological biomarkers and motion estimation for quantitative reconstruction. Future work should compare HEM+VAST with prior 4D PET reconstruction methods at the same 33-ms frame duration and matched noise levels.

eess.IV↗

Artificial Intelligence-Guided PET Image Reconstruction and Multi-Tracer Imaging: Novel Methods, Challenges, And Opportunities

LAFOV PET/CT has the potential to unlock new applications such as ultra-low dose PET/CT imaging, multiplexed imaging, for biomarker development and for faster AI-driven reconstruction, but further work is required before these can be deployed in clinical routine. LAFOV PET/CT has unrivalled sensitivity but has a spatial resolution of an equivalent scanner with a shorter axial field of view. AI approaches are increasingly explored as potential avenues to enhance image resolution.

physics.med-ph↗

Advancing Positron Emission Tomography Image Quantification: Artificial Intelligence-Driven Methods, Clinical Challenges, and Emerging Opportunities in Long-Axial Field-of-View Positron Emission Tomography/Computed Tomography Imaging

MTV is increasingly recognized as an accurate estimate of disease burden, which has prognostic value, but its implementation has been hindered by the time-consuming need for manual segmentation of images. Automated quantitation using AI-driven approaches is promising. AI-driven automated quantification significantly reduces labor-intensive manual segmentation, improving consistency, reproducibility, and feasibility for routine clinical practice. AI-enhanced radiomics provides comprehensive characterization of tumor biology, capturing intratumoral and intertumoral heterogeneity beyond what conventional volumetric metrics alone offer, supporting improved patient stratification and therapy planning. AI-driven segmentation of normal organs improves radioligand therapy planning by enabling accurate dose predictions and comprehensive organ-based radiomics analysis, further refining personalized patient management.

physics.med-ph↗