A Perspective on Deep Imaging

The combination of tomographic imaging and deep learning, or machine learning in general, promises to empower not only image analysis but also image reconstruction. The latter aspect is considered in this perspective article with an emphasis on medical imaging to develop a new generation of image reconstruction theories and techniques. This direction might lead to intelligent utilization of domain knowledge from big data, innovative approaches for image reconstruction, and superior performance in clinical and preclinical applications. To realize the full impact of machine learning on medical imaging, major challenges must be addressed.

q-bio.QM↗

Bibliometric Index for Academic Leadership

Academic leadership is essential for research innovation and impact. Until now, there has been no dedicated measure of leadership by bibliometrics. Popular bibliometric indices are mainly based on academic output, such as the journal impact factor and the number of citations. Here we develop an academic leadership index based on readily available bibliometric data that is sensitive to not only academic output but also research efficiency. Our leadership index was tested in two studies on peer-reviewed journal papers by extramurally-funded principal investigators in the field of life sciences from China and the USA, respectively. The leadership performance of these principal investigators was quantified and compared relative to university rank and other factors. As a validation measure, we show that the highest average leadership index was achieved by principal investigators at top national universities in both countries. More interestingly, our results also indicate that on an individual basis, strong leadership and high efficiency are not necessarily associated with those at top-tier universities nor with the most funding. This leadership index may become the basis of a comprehensive merit system, facilitating academic evaluation and resource management.

cs.DL↗

Low-dose CT denoising with convolutional neural network

To reduce the potential radiation risk, low-dose CT has attracted much attention. However, simply lowering the radiation dose will lead to significant deterioration of the image quality. In this paper, we propose a noise reduction method for low-dose CT via deep neural network without accessing original projection data. A deep convolutional neural network is trained to transform low-dose CT images towards normal-dose CT images, patch by patch. Visual and quantitative evaluation demonstrates a competing performance of the proposed method.

physics.med-ph↗

Low-Dose CT via Deep Neural Network

In order to reduce the potential radiation risk, low-dose CT has attracted more and more attention. However, simply lowering the radiation dose will significantly degrade the imaging quality. In this paper, we propose a noise reduction method for low-dose CT via deep learning without accessing the original projection data. An architecture of deep convolutional neural network was considered to map the low-dose CT images into its corresponding normal-dose CT images patch by patch. Qualitative and quantitative evaluations demonstrate a state-the-art performance of the proposed method.

physics.med-ph↗

Theoretical analysis on x-ray cylindrical grating interferometer

Grating interferometer is a state of art x-ray imaging approach, which can simultaneously acquire information of x-ray attenuation, phase shift, and small angle scattering. This approach is very sensitive to micro-structural variation and offers superior contrast resolution for biological soft tissues. The present grating interferometer often uses flat gratings, with serious limitations in the field of view and the flux of photons. The use of curved gratings allows perpendicular incidence of x-rays on the gratings, and gives higher visibility over a larger field of view than a conventional interferometer with flat gratings. In the study, we present a rigorous theoretical analysis of the self-imaging of curved transmission gratings based on Rayleigh-Sommerfeld diffraction. Numerical simulations have demonstrated the self-imaging phenomenon of cylindrical grating interferometer. The theoretical results are in agreement with the results of numerical simulations.

physics.med-ph↗

A Pilot Study on Coupling CT and MRI through Use of Semiconductor Nanoparticles

CT and MRI are the two most widely used imaging modalities in healthcare, each with its own merits and drawbacks. Combining these techniques in one machine could provide unprecedented resolution and sensitivity in a single scan, and serve as an ideal platform to explore physical coupling of x-ray excitation and magnetic resonance. Molecular probes such as functionalized nanophosphors present an opportunity to demonstrate a synergy between these modalities. However, a simultaneous CT-MRI scanner does not exist at this moment. As a pilot study, here we propose a mechanism in which water solutions containing LiGa5O8:Cr3+ nanophosphors can be excited with x-rays to store energy, and these excited particles may subsequently influence the T2 relaxation times of the solutions so that a difference in T2 can be measured by MRI before and after x-ray excitation. The trends seen in our study suggest that a measurable effect may exist from x-ray excitation of the nanophosphors. However, there are several experimental conditions that hinder the clarity of the results to be statistically significant up to a commonly accepted level (p=0.05), including insoluble nanoparticles and inter-scan variability. Nevertheless, the initial results from our experiments seem a consistent and inspiring story that x-rays modify MRI T2 values around nanophosphors. Upon availability of soluble nanophosphors, we will repeat our experiments to confirm these observations.

physics.med-ph↗

X-optogenetics and U-optogenetics: Feasibility and Possibilities

To address these limitations of optogenetics, here we propose two new methods for optogenetic stimulation. The first is x-optogenetics, which uses visible light-emitting nanophosphors stimulated by focused x-rays. This idea is not new but the application to optogenetics is novel. X-rays can penetrate much more deeply than infrared light and could allow for nerve cell stimulation in any part of the brain. In this paper, we discuss the feasibility and possibilities of such a method by describing the advances in nanomaterials, x-ray focusing, and x-ray sources. Also, we discuss concerns when dealing with x-rays such as radiation dosage. Through the use of quantities and assumptions backed by recent literature, manufacturer specifications, and personal correspondence, a full feasibility analysis of x-optogenetics is completed. The second proposed method we explore is u-optogenetics, which is the application of sonoluminescence to optogenetics. Such a technique uses ultrasound waves instead of x-rays to induce light emission, so there would be no introduction of radiation. However, the penetration depth of ultrasound is less than that of x-ray. The key issues affecting feasibility are laid out for further investigation into both x-optogenetics and u-optogenetics.

physics.bio-ph↗

Physical Foundation for General Interior Tomography

Gauge invariability guarantees the same form of the Maxwell equations in different coordinate systems, and is instrumental for electromagnetic cloaking to hide a region of interest (ROI) perfectly. On the other hand, interior tomography is to reconstruct an ROI exactly. In this article, the recent results in these two disconnected areas are brought together to justify the general interior tomography principle. Several opportunities are suggested for tomographic research.

physics.med-ph↗

Local Filtering Fundamentally Against Wide Spectrum

Chen et al. (1) applied three-dimensional (3D) Fourier filtering together with equal-slope tomographic reconstruction for an observation of nearly all the atoms in a multiply twinned platinum nanoparticle. However, their methodology suffers from fundamental methodological flaws, as initially brought up by a recent Communications Arising (2) and now analyzed in-depth in this report written on June 20, 2014. The authors of (1) read this report and wrote a reply containing 5 points. While we have solid reasons to disagree with their points, we will not include our responses here, and will address their first two points using Nature's online commenting facility. References 1. Chen, C.C., et al., Three-dimensional imaging of dislocations in a nanoparticle at atomic resolution. Nature 496(7443):74-79, 2013 2. Rez, P. and M.M.J. Treacy, Three-dimensional imaging of dislocations. Nature 503(E1):74-79, 2013

physics.data-an↗

Modulated Luminescent Tomography

We propose and analyze a mathematical model of Modulated Luminescent Tomography. We show that when single X-rays or focused X-rays are used as an excitation, the problem is similar to the inversion of weighted X-ray transforms. In particular, we give an explicit inversion in the case of Dual Cone X-ray excitation.

math.AP↗

First CT-MRI Scanner for Multi-dimensional Synchrony and Multi-physical Coupling

We propose to prototype the first CT-MRI scanner for radiation therapy and basic research, demonstrate its transformative biomedical potential, and initiate a paradigm shift in multimodality imaging. Our design consists of a double donut-shaped pair of permanent magnets to form a regionally uniform ~0.5T magnetic field and leave room for a stationary 9-source interior CT gantry at 3 tube voltages (triple-energy CT). Image reconstruction will be in a compressive sensing framework. Please discuss with Dr. Ge Wang (ge-wang@ieee.org) if you are interested in collaborative opportunities.

physics.med-ph↗

Attenuation map reconstruction from TOF PET data

To reconstruct a radioactive tracer distribution with positron emission tomography (PET), the background attenuation correction is needed to eliminate image artifacts. Recent research shows that time-of-flight (TOF) PET data determine the attenuation sinogram up to a constant, and its gradient can be computed using an analytic algorithm. In this paper, we study a direct estimation of the sinogram only from TOF PET data. First, the gradient of the attenuation sinogram is estimated using the aforementioned algorithm. Then, a relationship is established to link the differential attenuation sinogram and the underlying attenuation background. Finally, an iterative algorithm is designed to determine the attenuation sinogram accurately and stably. A 2D numerical simulation study is conducted to verify the correctness of our proposed approach.

physics.med-ph↗

Top-level Design and Pilot Analysis of Low-end CT Scanners Based on Linear Scanning for Developing Countries

Purpose: The goal is to develop a new architecture for computed tomography (CT) which is at an ultra-low-dose for developing countries, especially in rural areas. Methods: The proposed scheme is inspired by the recently developed compressive sensing and interior tomography techniques, where the data acquisition system targets a region of interest (ROI) to acquire limited and truncated data. The source and detector are translated in opposite directions for either ROI reconstruction with one or more localized linear scans or global reconstruction by combining multiple ROI reconstructions. In other words, the popular slip ring is replaced by a translation based setup, and the instrumentation cost is reduced by a relaxation of the imaging speed requirement. Results: The various translational scanning modes are theoretically analyzed, and the scanning parameters are optimized. The numerical simulation results from different numbers of linear scans confirm the feasibility of the proposed scheme, and suggest two preferred low-end systems for horizontal and vertical patient positions respectively. Conclusion: Ultra-low-cost x-ray CT is feasible with our proposed combination of linear scanning, compressive sensing, and interior tomography. The proposed architecture can be tailored into permanent, movable, or reconfigurable systems as desirable. Advanced image registration and spectral imaging features can be included as well.

physics.med-ph↗

Dictionary-Learning-Based Reconstruction Method for Electron Tomography

Electron tomography usually suffers from so called missing wedge artifacts caused by limited tilt angle range. An equally sloped tomography (EST) acquisition scheme (which should be called the linogram sampling scheme) was recently applied to achieve 2.4-angstrom resolution. On the other hand, a compressive sensing-inspired reconstruction algorithm, known as adaptive dictionary based statistical iterative reconstruction (ADSIR), has been reported for x-ray computed tomography. In this paper, we evaluate the EST, ADSIR and an ordered-subset simultaneous algebraic reconstruction technique (OS-SART), and compare the ES and equally angled (EA) data acquisition modes. Our results show that OS-SART is comparable to EST, and the ADSIR outperforms EST and OS-SART. Furthermore, the equally sloped projection data acquisition mode has no advantage over the conventional equally angled mode in the context.

cs.CV↗

Micro-modulated luminescence tomography

Imaging depth of optical microscopy has been fundamentally limited to millimeter or sub-millimeter due to light scattering. X-ray microscopy can resolve spatial details of few microns deeply inside a sample but the contrast resolution is still inadequate to depict heterogeneous features at cellular or sub-cellular levels. To enhance and enrich biological contrast at large imaging depth, various nanoparticles are introduced and become essential to basic research and molecular medicine. Nanoparticles can be functionalized as imaging probes, similar to fluorescent and bioluminescent proteins. LiGa5O8:Cr3+ nanoparticles were recently synthesized to facilitate luminescence energy storage with x-ray pre-excitation and the subsequently stimulated luminescence emission by visible/near-infrared (NIR) light. In this paper, we suggest a micro-modulated luminescence tomography (MLT) approach to quantify a nanophosphor distribution in a thick biological sample with high resolution. Our numerical simulation studies demonstrate the feasibility of the proposed approach.

physics.bio-ph↗

Stored Luminescence Computed Tomography

The phosphor nanoparticles made of doped semiconductors, pre-excited by well-collimated X-ray radiation, were recently reported for their light emission upon NIR light stimulation. The characteristics of X-ray energy storage and NIR stimulated emission is highly desirable to design targeting probes and improve molecular and cellular imaging. Here we propose stored luminescence computed tomography (SLCT), perform realistic numerical simulation, and demonstrate a much-improved spatial resolution in a preclinical research context. The future opportunities are also discussed along this direction.

physics.bio-ph↗

Meaning of Interior Tomography

The classic imaging geometry for computed tomography is for collection of un-truncated projections and reconstruction of a global image, with the Fourier transform as the theoretical foundation that is intrinsically non-local. Recently, interior tomography research has led to theoretically exact relationships between localities in the projection and image spaces and practically promising reconstruction algorithms. Initially, interior tomography was developed for x-ray computed tomography. Then, it has been elevated as a general imaging principle. Finally, a novel framework known as omni-tomography is being developed for grand fusion of multiple imaging modalities, allowing tomographic synchrony of diversified features.

physics.med-ph↗

Dynamic Bowtie for Fan-beam CT

A bowtie is a filter used to shape an x-ray beam and equalize its flux reaching different detector channels. For development of spectral CT with energy-discriminative photon-counting (EDPC) detectors, here we propose and evaluate a dynamic bowtie for performance optimization based on a patient model or a scout scan. Our dynamic bowtie modifies an x-ray beam intensity profile by mechanical rotation and adaptive adjustment of the x-ray source flux. First, a mathematical model for dynamic bowtie filtering is established for an elliptical section in fan-beam geometry, and the contour of the optimal bowtie is derived. Then, numerical simulation is performed to compare the performance of the dynamic bowtie in the cases of an ideal phantom and a realistic cross-section relative to the counterparts without any bowtie and with a fixed bowtie respectively. Our dynamic bowtie can equalize the expected numbers of photons in the case of an ideal phantom. In practical cases, our dynamic bowtie can effectively reduce the dynamic range of detected signals inside the field of view. Although our design is optimized for an elliptical phantom, the resultant dynamic bowtie can be applied to a real fan-beam scan if the underlying cross-section can be approximated as an ellipse. Furthermore, our design methodology can be applied to specify an optimized dynamic bowtie for any cross-section of a patient, preferably using rapid prototyping technology. This fan-beam dynamic bowtie work could be extended to the cone-beam geometry in a follow-up study.

physics.med-ph↗