Searcharxiv⌕ Search

arXiv subjects

Ge Wang

Publications and source records attributed to Ge Wang.

At least 127 records · Page 7Linked to original sources

3D Photon Counting CT Image Super-Resolution Using Conditional Diffusion Model

This study aims to improve photon counting CT (PCCT) image resolution using denoising diffusion probabilistic models (DDPM). Although DDPMs have shown superior performance when applied to various computer vision tasks, their effectiveness has yet to be translated to high dimensional CT super-resolution. To train DDPMs in a conditional sampling manner, we first leverage CatSim to simulate realistic lower resolution PCCT images from high-resolution CT scans. Since maximizing DDPM performance is time-consuming for both inference and training, especially on high-dimensional PCCT data, we explore both 2D and 3D networks for conditional DDPM and apply methods to accelerate training. In particular, we decompose the 3D task into efficient 2D DDPMs and design a joint 2D inference in the reverse diffusion process that synergizes 2D results of all three dimensions to make the final 3D prediction. Experimental results show that our DDPM achieves improved results versus baseline reference models in recovering high-frequency structures, suggesting that a framework based on realistic simulation and DDPM shows promise for improving PCCT resolution.

cs.CV↗

CT-based Anomaly Detection of Liver Tumors Using Generative Diffusion Prior

CT is a main modality for imaging liver diseases, valuable in detecting and localizing liver tumors. Traditional anomaly detection methods analyze reconstructed images to identify pathological structures. However, these methods may produce suboptimal results, overlooking subtle differences among various tissue types. To address this challenge, here we employ generative diffusion prior to inpaint the liver as the reference facilitating anomaly detection. Specifically, we use an adaptive threshold to extract a mask of abnormal regions, which are then inpainted using a diffusion prior to calculating an anomaly score based on the discrepancy between the original CT image and the inpainted counterpart. Our methodology has been tested on two liver CT datasets, demonstrating a significant improvement in detection accuracy, with a 7.9% boost in the area under the curve (AUC) compared to the state-of-the-art. This performance gain underscores the potential of our approach to refine the radiological assessment of liver diseases.

physics.med-ph↗

Integrating AI in College Education: Positive yet Mixed Experiences with ChatGPT

The integration of artificial intelligence (AI) chatbots into higher education marks a shift towards a new generation of pedagogical tools, mirroring the arrival of milestones like the internet. With the launch of ChatGPT-4 Turbo in November 2023, we developed a ChatGPT-based teaching application (https://chat.openai.com/g/g-1imx1py4K-chatge-medical-imaging) and integrated it into our undergraduate medical imaging course in the Spring 2024 semester. This study investigates the use of ChatGPT throughout a semester-long trial, providing insights into students' engagement, perception, and the overall educational effectiveness of the technology. We systematically collected and analyzed data concerning students' interaction with ChatGPT, focusing on their attitudes, concerns, and usage patterns. The findings indicate that ChatGPT offers significant advantages such as improved information access and increased interactivity, but its adoption is accompanied by concerns about the accuracy of the information provided and the necessity for well-defined guidelines to optimize its use.

cs.AI↗

Data-driven imaging geometric recovery of ultrahigh resolution robotic micro-CT for in-vivo and other applications

We introduce an ultrahigh-resolution (50μm\) robotic micro-CT design for localized imaging of carotid plaques using robotic arms, cutting-edge detector, and machine learning technologies. To combat geometric error-induced artifacts in interior CT scans, we propose a data-driven geometry estimation method that maximizes the consistency between projection data and the reprojection counterparts of a reconstructed volume. Particularly, we use a normalized cross correlation metric to overcome the projection truncation effect. Our approach is validated on a robotic CT scan of a sacrificed mouse and a micro-CT phantom scan, both producing sharper images with finer details than that prior correction.

physics.med-ph↗

Deciphering RNA Secondary Structure Prediction: A Probabilistic K-Rook Matching Perspective

The secondary structure of ribonucleic acid (RNA) is more stable and accessible in the cell than its tertiary structure, making it essential for functional prediction. Although deep learning has shown promising results in this field, current methods suffer from poor generalization and high complexity. In this work, we reformulate the RNA secondary structure prediction as a K-Rook problem, thereby simplifying the prediction process into probabilistic matching within a finite solution space. Building on this innovative perspective, we introduce RFold, a simple yet effective method that learns to predict the most matching K-Rook solution from the given sequence. RFold employs a bi-dimensional optimization strategy that decomposes the probabilistic matching problem into row-wise and column-wise components to reduce the matching complexity, simplifying the solving process while guaranteeing the validity of the output. Extensive experiments demonstrate that RFold achieves competitive performance and about eight times faster inference efficiency than the state-of-the-art approaches. The code and Colab demo are available in (http://github.com/A4Bio/RFold).

q-bio.BM↗

Thermal conductivity of nonunitary triplet superconductors: application to UTe$_2$

There is considerable evidence that the heavy fermion material UTe$_2$ is a spin-triplet superconductor, possibly manifesting time-reversal symmetry breaking, as measured by Kerr effect and muon spin resonance experiments below the critical temperature, in some samples. Such signals can arise due to a chiral orbital state, or possible nonunitary pairing. Although experiments at low $T$ appear to be consistent with point nodes in the spectral gap, the detailed form of the order parameter and even the nodal positions are not yet determined. Thermal conductivity measurements can extend to quite low temperatures, with varying heat current direction can therefore provide information on the order parameter structure. Here we derive a general expression for the thermal conductivity of a spin triplet superconductor, and use it to compare the low-temperature behavior of various states proposed for UTe$_2$.

cond-mat.supr-con↗

Cardiovascular Disease Detection from Multi-View Chest X-rays with BI-Mamba

Accurate prediction of Cardiovascular disease (CVD) risk in medical imaging is central to effective patient health management. Previous studies have demonstrated that imaging features in computed tomography (CT) can help predict CVD risk. However, CT entails notable radiation exposure, which may result in adverse health effects for patients. In contrast, chest X-ray emits significantly lower levels of radiation, offering a safer option. This rationale motivates our investigation into the feasibility of using chest X-ray for predicting CVD risk. Convolutional Neural Networks (CNNs) and Transformers are two established network architectures for computer-aided diagnosis. However, they struggle to model very high resolution chest X-ray due to the lack of large context modeling power or quadratic time complexity. Inspired by state space sequence models (SSMs), a new class of network architectures with competitive sequence modeling power as Transfomers and linear time complexity, we propose Bidirectional Image Mamba (BI-Mamba) to complement the unidirectional SSMs with opposite directional information. BI-Mamba utilizes parallel forward and backwark blocks to encode longe-range dependencies of multi-view chest X-rays. We conduct extensive experiments on images from 10,395 subjects in National Lung Screening Trail (NLST). Results show that BI-Mamba outperforms ResNet-50 and ViT-S with comparable parameter size, and saves significant amount of GPU memory during training. Besides, BI-Mamba achieves promising performance compared with previous state of the art in CT, unraveling the potential of chest X-ray for CVD risk prediction.

eess.IV↗

Disease-informed Adaptation of Vision-Language Models

In medical image analysis, the expertise scarcity and the high cost of data annotation limits the development of large artificial intelligence models. This paper investigates the potential of transfer learning with pre-trained vision-language models (VLMs) in this domain. Currently, VLMs still struggle to transfer to the underrepresented diseases with minimal presence and new diseases entirely absent from the pretraining dataset. We argue that effective adaptation of VLMs hinges on the nuanced representation learning of disease concepts. By capitalizing on the joint visual-linguistic capabilities of VLMs, we introduce disease-informed contextual prompting in a novel disease prototype learning framework. This approach enables VLMs to grasp the concepts of new disease effectively and efficiently, even with limited data. Extensive experiments across multiple image modalities showcase notable enhancements in performance compared to existing techniques.

cs.CV↗

Specialty-Oriented Generalist Medical AI for Chest CT Screening

Modern medical records include a vast amount of multimodal free text clinical data and imaging data from radiology, cardiology, and digital pathology. Fully mining such big data requires multitasking; otherwise, occult but important aspects may be overlooked, adversely affecting clinical management and population healthcare. Despite remarkable successes of AI in individual tasks with single-modal data, the progress in developing generalist medical AI remains relatively slow to combine multimodal data for multitasks because of the dual challenges of data curation and model architecture. The data challenge involves querying and curating multimodal structured and unstructured text, alphanumeric, and especially 3D tomographic scans on an individual patient level for real-time decisions and on a scale to estimate population health statistics. The model challenge demands a scalable and adaptable network architecture to integrate multimodal datasets for diverse clinical tasks. Here we propose the first-of-its-kind medical multimodal-multitask foundation model (M3FM) with application in lung cancer screening and related tasks. After we curated a comprehensive multimodal multitask dataset consisting of 49 clinical data types including 163,725 chest CT series and 17 medical tasks involved in LCS, we develop a multimodal question-answering framework as a unified training and inference strategy to synergize multimodal information and perform multiple tasks via free-text prompting. M3FM consistently outperforms the state-of-the-art single-modal task-specific models, identifies multimodal data elements informative for clinical tasks and flexibly adapts to new tasks with a small out-of-distribution dataset. As a specialty-oriented generalist medical AI model, M3FM paves the way for similar breakthroughs in other areas of medicine, closing the gap between specialists and the generalist.

eess.IV↗

High Noise Scheduling is a Must

Consistency models possess high capabilities for image generation, advancing sampling steps to a single step through their advanced techniques. Current advancements move one step forward consistency training techniques and eliminates the limitation of distillation training. Even though the proposed curriculum and noise scheduling in improved training techniques yield better results than basic consistency models, it lacks well balanced noise distribution and its consistency between curriculum. In this study, it is investigated the balance between high and low noise levels in noise distribution and offered polynomial noise distribution to maintain the stability. This proposed polynomial noise distribution is also supported with a predefined Karras noises to prevent unique noise levels arises with Karras noise generation algorithm. Furthermore, by elimination of learned noisy steps with a curriculum based on sinusoidal function increase the performance of the model in denoising. To make a fair comparison with the latest released consistency model training techniques, experiments are conducted with same hyper-parameters except curriculum and noise distribution. The models utilized during experiments are determined with low depth to prove the robustness of our proposed technique. The results show that the polynomial noise distribution outperforms the model trained with log-normal noise distribution, yielding a 33.54 FID score after 100,000 training steps with constant discretization steps. Additionally, the implementation of a sinusoidal-based curriculum enhances denoising performance, resulting in a FID score of 30.48.

cs.LG↗

Low-dose CT Denoising with Language-engaged Dual-space Alignment

While various deep learning methods were proposed for low-dose computed tomography (CT) denoising, they often suffer from over-smoothing, blurring, and lack of explainability. To alleviate these issues, we propose a plug-and-play Language-Engaged Dual-space Alignment loss (LEDA) to optimize low-dose CT denoising models. Our idea is to leverage large language models (LLMs) to align denoised CT and normal dose CT images in both the continuous perceptual space and discrete semantic space, which is the first LLM-based scheme for low-dose CT denoising. LEDA involves two steps: the first is to pretrain an LLM-guided CT autoencoder, which can encode a CT image into continuous high-level features and quantize them into a token space to produce semantic tokens derived from the LLM's vocabulary; and the second is to minimize the discrepancy between the denoised CT images and normal dose CT in terms of both encoded high-level features and quantized token embeddings derived by the LLM-guided CT autoencoder. Extensive experimental results on two public LDCT denoising datasets demonstrate that our LEDA can enhance existing denoising models in terms of quantitative metrics and qualitative evaluation, and also provide explainability through language-level image understanding. Source code is available at https://github.com/hao1635/LEDA.

eess.IV↗

Image Reconstruction Using a Mixture Score Function (MSF)

Computed tomography (CT) reconstructs volumetric images using X-ray projection data acquired from multiple angles around an object. For low-dose or sparse-view CT scans, the classic image reconstruction algorithms often produce severe noise and artifacts. To address this issue, we develop a novel iterative image reconstruction method based on maximum a posteriori (MAP) estimation. In the MAP framework, the score function, i.e., the gradient of the logarithmic probability density distribution, plays a crucial role as an image prior in the iterative image reconstruction process. By leveraging the Gaussian mixture model, we derive a novel score matching formula to establish an advanced score function (ADSF) through deep learning. Integrating the new ADSF into the image reconstruction process, a new ADSF iterative reconstruction method is developed to improve image reconstruction quality. The convergence of the ADSF iterative reconstruction algorithm is proven through mathematical analysis. The performance of the ADSF reconstruction method is also evaluated on both public medical image datasets and clinical raw CT datasets. Our results show that the ADSF reconstruction method can achieve better denoising and deblurring effects than the state-of-the-art reconstruction methods, showing excellent generalizability and stability.

physics.med-ph↗

Photon-counting CT using a Conditional Diffusion Model for Super-resolution and Texture-preservation

Ultra-high resolution images are desirable in photon counting CT (PCCT), but resolution is physically limited by interactions such as charge sharing. Deep learning is a possible method for super-resolution (SR), but sourcing paired training data that adequately models the target task is difficult. Additionally, SR algorithms can distort noise texture, which is an important in many clinical diagnostic scenarios. Here, we train conditional denoising diffusion probabilistic models (DDPMs) for PCCT super-resolution, with the objective to retain textural characteristics of local noise. PCCT simulation methods are used to synthesize realistic resolution degradation. To preserve noise texture, we explore decoupling the noise and signal image inputs and outputs via deep denoisers, explicitly mapping to each during the SR process. Our experimental results indicate that our DDPM trained on simulated data can improve sharpness in real PCCT images. Additionally, the disentanglement of noise from the original image allows our model more faithfully preserve noise texture.

eess.IV↗

Decorrelative Network Architecture for Robust Electrocardiogram Classification

Artificial intelligence has made great progress in medical data analysis, but the lack of robustness and trustworthiness has kept these methods from being widely deployed. As it is not possible to train networks that are accurate in all scenarios, models must recognize situations where they cannot operate confidently. Bayesian deep learning methods sample the model parameter space to estimate uncertainty, but these parameters are often subject to the same vulnerabilities, which can be exploited by adversarial attacks. We propose a novel ensemble approach based on feature decorrelation and Fourier partitioning for teaching networks diverse complementary features, reducing the chance of perturbation-based fooling. We test our approach on single and multi-channel electrocardiogram classification, and adapt adversarial training and DVERGE into the Bayesian ensemble framework for comparison. Our results indicate that the combination of decorrelation and Fourier partitioning generally maintains performance on unperturbed data while demonstrating superior robustness and uncertainty estimation on projected gradient descent and smooth adversarial attacks of various magnitudes. Furthermore, our approach does not require expensive optimization with adversarial samples, adding much less compute to the training process than adversarial training or DVERGE. These methods can be applied to other tasks for more robust and trustworthy models.

cs.LG↗

Enabling Competitive Performance of Medical Imaging with Diffusion Model-generated Images without Privacy Leakage

Deep learning methods have impacted almost every research field, demonstrating notable successes in medical imaging tasks such as denoising and super-resolution. However, the prerequisite for deep learning is data at scale, but data sharing is expensive yet at risk of privacy leakage. As cutting-edge AI generative models, diffusion models have now become dominant because of their rigorous foundation and unprecedented outcomes. Here we propose a latent diffusion approach for data synthesis without compromising patient privacy. In our exemplary case studies, we develop a latent diffusion model to generate medical CT, MRI and PET images using publicly available datasets. We demonstrate that state-of-the-art deep learning-based denoising/super-resolution networks can be trained on our synthetic data to achieve image quality equivalent to what the same network can achieve after being trained on the original data (the p values well exceeding the threshold of 0.05). In our advanced diffusion model, we specifically embed a safeguard mechanism to protect patient privacy effectively and efficiently. Consequently, every synthetic image is guaranteed to be different by a pre-specified threshold from the closest counterpart in the original patient dataset. Our approach allows privacy-proof public sharing of diverse big datasets for development of deep models, potentially enabling federated learning at the level of input data instead of local network weights.

physics.med-ph↗

Parallel Diffusion Model-based Sparse-view Cone-beam Breast CT

Breast cancer is the most prevalent cancer among women worldwide, and early detection is crucial for reducing its mortality rate and improving quality of life. Dedicated breast computed tomography (CT) scanners offer better image quality than mammography and tomosynthesis in general but at higher radiation dose. To enable breast CT for cancer screening, the challenge is to minimize the radiation dose without compromising image quality, according to the ALARA principle (as low as reasonably achievable). Over the past years, deep learning has shown remarkable successes in various tasks, including low-dose CT especially few-view CT. Currently, the diffusion model presents the state of the art for CT reconstruction. To develop the first diffusion model-based breast CT reconstruction method, here we report innovations to address the large memory requirement for breast cone-beam CT reconstruction and high computational cost of the diffusion model. Specifically, in this study we transform the cutting-edge Denoising Diffusion Probabilistic Model (DDPM) into a parallel framework for sub-volume-based sparse-view breast CT image reconstruction in projection and image domains. This novel approach involves the concurrent training of two distinct DDPM models dedicated to processing projection and image data synergistically in the dual domains. Our experimental findings reveal that this method delivers competitive reconstruction performance at half to one-third of the standard radiation doses. This advancement demonstrates an exciting potential of diffusion-type models for volumetric breast reconstruction at high-resolution with much-reduced radiation dose and as such hopefully redefines breast cancer screening and diagnosis.

eess.IV↗

Noise suppression in photon-counting CT using unsupervised Poisson flow generative models

Deep learning has proven to be important for CT image denoising. However, such models are usually trained under supervision, requiring paired data that may be difficult to obtain in practice. Diffusion models offer unsupervised means of solving a wide range of inverse problems via posterior sampling. In particular, using the estimated unconditional score function of the prior distribution, obtained via unsupervised learning, one can sample from the desired posterior via hijacking and regularization. However, due to the iterative solvers used, the number of function evaluations (NFE) required may be orders of magnitudes larger than for single-step samplers. In this paper, we present a novel image denoising technique for photon-counting CT by extending the unsupervised approach to inverse problem solving to the case of Poisson flow generative models (PFGM)++. By hijacking and regularizing the sampling process we obtain a single-step sampler, that is NFE=1. Our proposed method incorporates posterior sampling using diffusion models as a special case. We demonstrate that the added robustness afforded by the PFGM++ framework yields significant performance gains. Our results indicate competitive performance compared to popular supervised, including state-of-the-art diffusion-style models with NFE=1 (consistency models), unsupervised, and non-deep learning-based image denoising techniques, on clinical low-dose CT data and clinical images from a prototype photon-counting CT system developed by GE HealthCare.

physics.med-ph↗

A coronary artery phantom for task-based CT performance assessment and a comparative study of clinical CT, photon counting CT, and micro CT

While drastic improvements in CT technology have occurred in the past 25 years, spatial resolution is one area where progress has been limited until recently. New photon counting CT systems, are capable of much better spatial resolution than their (energy integrating) predecessors. These improvements have the potential to improve the evaluation obstructive coronary artery disease by enabling more accurate delineation between calcified plaque and coronary vessel lumen. A new set of vessel phantoms has been designed and manufactured for quantifying this improvement. Comparisons are made between an existing clinical CT system, a prototype photon counting system, with images from a micro CT system being used as the gold standard. Scans were made of the same objects on all three systems. The resulting images were registered and the luminal cross section areas were compared. Luminal cross-sections near calcified plaques were reduced due to blooming, but this effect was much less pronounced in images from the prototype photon counting system as compared to the images from the clinical CT system.

physics.med-ph↗