SearcharxivSearch

arXiv subjects

Georges El Fakhri

Publications and source records attributed to Georges El Fakhri.

At least 19 recordsLinked to original sources

Attention Consistent Longitudinal Medical Visual Question Answering Guided by Vision Foundation Models

Longitudinal medical visual question answering (VQA) requires reasoning about anatomical differences between an image of a current time point and an image of a referred time point. We propose an attention-guided encoder-decoder for this task with chest X-rays. Instead of conventional direct contrast, we propose to include a lightweight affine registration module to reduce nuisance motion by co-registering the current image to the reference image with a small registration regularizer. The registered image pair is fed into the image encoder, followed by a frozen DINO-based mask generator and a trainable adaptive mask generator to produce masks applied to the original image pairs. The masked image pairs are again fed into the image encoder and concatenated with text features as the input to a multimodal transformer-based decoder to generate final answers. To facilitate learning stabilization and clarify the change signal, inspired by DINO-v3, we include additional auxiliary objectives, including a mask rebuilding loss, a pairwise Gram-style consistency loss, and a KoLeo uniformity loss, which enhances the geometry of the representation. On the Medical-Diff-VQA benchmark, the model delivers strong BLEU, ROUGE-L, CIDEr, and METEOR scores while offering intrinsic interpretability through the shared saliency mask. These results support saliency-conditioned generation with mild pre-alignment as a principled framework for longitudinal reasoning in medical VQA. Our training strategy also illustrates the potential of a paradigm in utilizing image foundation models in biomedicine: optimizing both supervised and unsupervised learning objectives simultaneously.

eess.IV

An Open Multi-Center Whole-Body FDG PET/CT Foundation Model for Tumor Segmentation

The synergistic interpretation of anatomical information from computed tomography (CT) and metabolic information from positron emission tomography (PET) is important to oncologic imaging. However, existing deep learning methods for PET/CT remain largely task-specific, are often trained on single-center cohorts, or adopt dual-branch fusion schemes that delay cross-modal interaction and underutilize early spatial correspondence between PET and CT. To address these limitations, we present an open-source, multi-center, whole-body FDG PET/CT foundation model utilizing 4,997 harmonized scans from four public datasets. Our framework employs hierarchical UNet-shaped backbones with early channel-wise concatenation, enabling anatomical and metabolic features to interact from the first embedding layer onward. We further introduce a masked autoencoding objective based on zero-mean imputation, combined with a weighted global reconstruction loss. This design avoids non-physical intensity discontinuities at masked-region boundaries that arise from learnable mask tokens. On downstream AutoPET lesion segmentation, the proposed models demonstrate strong label efficiency: with only 10\% of the labeled training data, they achieve performance comparable to models trained from scratch on the full dataset. Under extreme 5-shot linear probing, joint PET/CT pretraining also achieves higher Dice scores than separated-modality pretraining. This multi-center foundation model demonstrates label efficiency and cross-modality representation learning for PET/CT tumor segmentation. It provides a robust, open-source basis for advancing automated oncologic imaging, significantly reducing the need for large-scale manual annotations in clinical practice.

eess.IV

Unsupervised Adaptation from FDG to PSMA PET/CT for 3D Lesion Detection under Label Shift

In this work, we propose an unsupervised domain adaptation (UDA) framework for 3D volumetric lesion detection that adapts a detector trained on labeled FDG PET/CT to unlabeled PSMA PET/CT. Beyond covariate shift, cross tracer adaptation also exhibits label shift in both lesion size composition and the number of lesions per subject. We introduce self-training with two mechanisms that explicitly model and compensate for this label shift. First, we adaptively adjust the detection anchor shapes by re-estimating target domain box scales from selected pseudo labels and updating anchors with an exponential moving average. This increases positive anchor coverage for small PSMA lesions and stabilizes box regression. Second, instead of a fixed confidence threshold for pseudo-label selection, we allocate size bin-wise quotas according to the estimated target domain histogram over lesion volumes. The self-training alternates between supervised learning with prior-guided pseudo labeling on PSMA and supervised learning on labeled FDG. On AutoPET 2024, adapting from 501 labeled FDG studies to 369 $^{18}$F-PSMA studies, the proposed method improves both AP and FROC over the source-only baseline and conventional self-training without label-shift mitigation, indicating that modeling target lesion prevalence and size composition is an effective path to robust cross-tracer detection.

eess.IV

Rethinking Evaluation of Infrared Small Target Detection

As an essential vision task, infrared small target detection (IRSTD) has seen significant advancements through deep learning. However, critical limitations in current evaluation protocols impede further progress. First, existing methods rely on fragmented pixel- and target-level specific metrics, which fails to provide a comprehensive view of model capabilities. Second, an excessive emphasis on overall performance scores obscures crucial error analysis, which is vital for identifying failure modes and improving real-world system performance. Third, the field predominantly adopts dataset-specific training-testing paradigms, hindering the understanding of model robustness and generalization across diverse infrared scenarios. This paper addresses these issues by introducing a hybrid-level metric incorporating pixel- and target-level performance, proposing a systematic error analysis method, and emphasizing the importance of cross-dataset evaluation. These aim to offer a more thorough and rational hierarchical analysis framework, ultimately fostering the development of more effective and robust IRSTD models. An open-source toolkit has be released to facilitate standardized benchmarking.

cs.CV

UniMRSeg: Unified Modality-Relax Segmentation via Hierarchical Self-Supervised Compensation

Multi-modal image segmentation faces real-world deployment challenges from incomplete/corrupted modalities degrading performance. While existing methods address training-inference modality gaps via specialized per-combination models, they introduce high deployment costs by requiring exhaustive model subsets and model-modality matching. In this work, we propose a unified modality-relax segmentation network (UniMRSeg) through hierarchical self-supervised compensation (HSSC). Our approach hierarchically bridges representation gaps between complete and incomplete modalities across input, feature and output levels. % First, we adopt modality reconstruction with the hybrid shuffled-masking augmentation, encouraging the model to learn the intrinsic modality characteristics and generate meaningful representations for missing modalities through cross-modal fusion. % Next, modality-invariant contrastive learning implicitly compensates the feature space distance among incomplete-complete modality pairs. Furthermore, the proposed lightweight reverse attention adapter explicitly compensates for the weak perceptual semantics in the frozen encoder. Last, UniMRSeg is fine-tuned under the hybrid consistency constraint to ensure stable prediction under all modality combinations without large performance fluctuations. Without bells and whistles, UniMRSeg significantly outperforms the state-of-the-art methods under diverse missing modality scenarios on MRI-based brain tumor segmentation, RGB-D semantic segmentation, RGB-D/T salient object segmentation. The code will be released at https://github.com/Xiaoqi-Zhao-DLUT/UniMRSeg.

cs.CV

Power Battery Detection

Power batteries are essential components in electric vehicles, where internal structural defects can pose serious safety risks. We conduct a comprehensive study on a new task, power battery detection (PBD), which aims to localize the dense endpoints of cathode and anode plates from industrial X-ray images for quality inspection. Manual inspection is inefficient and error-prone, while traditional vision algorithms struggle with densely packed plates, low contrast, scale variation, and imaging artifacts. To address this issue and drive more attention into this meaningful task, we present PBD5K, the first large-scale benchmark for this task, consisting of 5,000 X-ray images from nine battery types with fine-grained annotations and eight types of real-world visual interference. To support scalable and consistent labeling, we develop an intelligent annotation pipeline that combines image filtering, model-assisted pre-labeling, cross-verification, and layered quality evaluation. We formulate PBD as a point-level segmentation problem and propose MDCNeXt, a model designed to extract and integrate multi-dimensional structure clues including point, line, and count information from the plate itself. To improve discrimination between plates and suppress visual interference, MDCNeXt incorporates two state space modules. The first is a prompt-filtered module that learns contrastive relationships guided by task-specific prompts. The second is a density-aware reordering module that refines segmentation in regions with high plate density. In addition, we propose a distance-adaptive mask generation strategy to provide robust supervision under varying spatial distributions of anode and cathode positions. The source code and datasets will be publicly available at \href{https://github.com/Xiaoqi-Zhao-DLUT/X-ray-PBD}{PBD5K}.

cs.CV

On hallucinations in AI-generated content for nuclear medicine imaging (the DREAM report)

Artificial intelligence-generated content (AIGC) has shown remarkable performance in nuclear medicine imaging (NMI), offering cost-effective software solutions for tasks such as image enhancement, motion correction, and attenuation correction. However, these advancements come with the risk of hallucinations, generating realistic yet factually incorrect content. Hallucinations can misrepresent anatomical and functional information, compromising diagnostic accuracy and clinical trust. This paper presents a comprehensive perspective of hallucination-related challenges in AIGC for NMI, introducing the DREAM report, which covers recommendations for definition, representative examples, detection and evaluation metrics, underlying causes, and mitigation strategies. This position statement paper aims to initiate a common understanding for discussions and future research toward enhancing AIGC applications in NMI, thereby supporting their safe and effective deployment in clinical practice.

eess.IV

Dual Prompting for Diverse Count-level PET Denoising

The to-be-denoised positron emission tomography (PET) volumes are inherent with diverse count levels, which imposes challenges for a unified model to tackle varied cases. In this work, we resort to the recently flourished prompt learning to achieve generalizable PET denoising with different count levels. Specifically, we propose dual prompts to guide the PET denoising in a divide-and-conquer manner, i.e., an explicitly count-level prompt to provide the specific prior information and an implicitly general denoising prompt to encode the essential PET denoising knowledge. Then, a novel prompt fusion module is developed to unify the heterogeneous prompts, followed by a prompt-feature interaction module to inject prompts into the features. The prompts are able to dynamically guide the noise-conditioned denoising process. Therefore, we are able to efficiently train a unified denoising model for various count levels, and deploy it to different cases with personalized prompts. We evaluated on 1940 low-count PET 3D volumes with uniformly randomly selected 13-22\% fractions of events from 97 $^{18}$F-MK6240 tau PET studies. It shows our dual prompting can largely improve the performance with informed count-level and outperform the count-conditional model.

eess.IV

Mixture-of-Shape-Experts (MoSE): End-to-End Shape Dictionary Framework to Prompt SAM for Generalizable Medical Segmentation

Single domain generalization (SDG) has recently attracted growing attention in medical image segmentation. One promising strategy for SDG is to leverage consistent semantic shape priors across different imaging protocols, scanner vendors, and clinical sites. However, existing dictionary learning methods that encode shape priors often suffer from limited representational power with a small set of offline computed shape elements, or overfitting when the dictionary size grows. Moreover, they are not readily compatible with large foundation models such as the Segment Anything Model (SAM). In this paper, we propose a novel Mixture-of-Shape-Experts (MoSE) framework that seamlessly integrates the idea of mixture-of-experts (MoE) training into dictionary learning to efficiently capture diverse and robust shape priors. Our method conceptualizes each dictionary atom as a shape expert, which specializes in encoding distinct semantic shape information. A gating network dynamically fuses these shape experts into a robust shape map, with sparse activation guided by SAM encoding to prevent overfitting. We further provide this shape map as a prompt to SAM, utilizing the powerful generalization capability of SAM through bidirectional integration. All modules, including the shape dictionary, are trained in an end-to-end manner. Extensive experiments on multiple public datasets demonstrate its effectiveness.

cs.CV

Anatomically and Metabolically Informed Diffusion for Unified Denoising and Segmentation in Low-Count PET Imaging

Positron emission tomography (PET) image denoising, along with lesion and organ segmentation, are critical steps in PET-aided diagnosis. However, existing methods typically treat these tasks independently, overlooking inherent synergies between them as correlated steps in the analysis pipeline. In this work, we present the anatomically and metabolically informed diffusion (AMDiff) model, a unified framework for denoising and lesion/organ segmentation in low-count PET imaging. By integrating multi-task functionality and exploiting the mutual benefits of these tasks, AMDiff enables direct quantification of clinical metrics, such as total lesion glycolysis (TLG), from low-count inputs. The AMDiff model incorporates a semantic-informed denoiser based on diffusion strategy and a denoising-informed segmenter utilizing nnMamba architecture. The segmenter constrains denoised outputs via a lesion-organ-specific regularizer, while the denoiser enhances the segmenter by providing enriched image information through a denoising revision module. These components are connected via a warming-up mechanism to optimize multi-task interactions. Experiments on multi-vendor, multi-center, and multi-noise-level datasets demonstrate the superior performance of AMDiff.

eess.IV

Inspiring the Next Generation of Segment Anything Models: Comprehensively Evaluate SAM and SAM 2 with Diverse Prompts Towards Context-Dependent Concepts under Different Scenes

As large-scale foundation models trained on billions of image--mask pairs covering a vast diversity of scenes, objects, and contexts, SAM and its upgraded version, SAM~2, have significantly influenced multiple fields within computer vision. Leveraging such unprecedented data diversity, they exhibit strong open-world segmentation capabilities, with SAM~2 further enhancing these capabilities to support high-quality video segmentation. While SAMs (SAM and SAM~2) have demonstrated excellent performance in segmenting context-independent concepts like people, cars, and roads, they overlook more challenging context-dependent (CD) concepts, such as visual saliency, camouflage, industrial defects, and medical lesions. CD concepts rely heavily on global and local contextual information, making them susceptible to shifts in different contexts, which requires strong discriminative capabilities from the model. The lack of comprehensive evaluation of SAMs limits understanding of their performance boundaries, which may hinder the design of future models. In this paper, we conduct a thorough evaluation of SAMs on 11 CD concepts across 2D and 3D images and videos in various visual modalities within natural, medical, and industrial scenes. We develop a unified evaluation framework for SAM and SAM~2 that supports manual, automatic, and intermediate self-prompting, aided by our specific prompt generation and interaction strategies. We further explore the potential of SAM~2 for in-context learning and introduce prompt robustness testing to simulate real-world imperfect prompts. Finally, we analyze the benefits and limitations of SAMs in understanding CD concepts and discuss their future development in segmentation tasks.

cs.CV

PET mapping of receptor occupancy using joint direct parametric reconstruction

Receptor occupancy (RO) studies using PET neuroimaging play a critical role in the development of drugs targeting the central nervous system (CNS). The conventional approach to estimate drug receptor occupancy consists in estimation of binding potential changes between two PET scans (baseline and post-drug injection). This estimation is typically performed separately for each scan by first reconstructing dynamic PET scan data before fitting a kinetic model to time activity curves. This approach fails to properly model the noise in PET measurements, resulting in poor RO estimates, especially in low receptor density regions. Objective: In this work, we evaluate a novel joint direct parametric reconstruction framework to directly estimate distributions of RO and other kinetic parameters in the brain from a pair of baseline and post-drug injection dynamic PET scans. Methods: The proposed method combines the use of regularization on RO maps with alternating optimization to enable estimation of occupancy even in low binding regions. Results: Simulation results demonstrate the quantitative improvement of this method over conventional approaches in terms of accuracy and precision of occupancy. The proposed method is also evaluated in preclinical in-vivo experiments using 11C-MK-6884 and a muscarinic acetylcholine receptor 4 positive allosteric modulator drug, showing improved estimation of receptor occupancy as compared to traditional estimators. Conclusion: The proposed joint direct estimation framework improves RO estimation compared to conventional methods, especially in intermediate to low-binding regions. Significance: This work could potentially facilitate the evaluation of new drug candidates targeting the CNS.

physics.med-ph

Free-breathing 3D cardiac extracellular volume (ECV) mapping using a linear tangent space alignment (LTSA) model

$\textbf{Purpose:}$ To develop a new method for free-breathing 3D extracellular volume (ECV) mapping of the whole heart at 3T. $\textbf{Methods:}$ A free-breathing 3D cardiac ECV mapping method was developed at 3T. T1 mapping was performed before and after contrast agent injection using a free-breathing ECG-gated inversion-recovery sequence with spoiled gradient echo readout. A linear tangent space alignment (LTSA) model-based method was used to reconstruct high-frame-rate dynamic images from (k,t)-space data sparsely sampled along a random stack-of-stars trajectory. Joint T1 and transmit B1 estimation was performed voxel-by-voxel for pre- and post-contrast T1 mapping. To account for the time-varying T1 after contrast agent injection, a linearly time-varying T1 model was introduced for post-contrast T1 mapping. ECV maps were generated by aligning pre- and post-contrast T1 maps through affine transformation. $\textbf{Results:}$ The feasibility of the proposed method was demonstrated using in vivo studies with six healthy volunteers at 3T. We obtained 3D ECV maps at a spatial resolution of 1.9$\times$1.9$\times$4.5 $mm^{3}$ and a FOV of 308$\times$308$\times$144 $mm^{3}$, with a scan time of 10.1$\pm$1.4 and 10.6$\pm$1.6 min before and after contrast agent injection, respectively. The ECV maps and the pre- and post-contrast T1 maps obtained by the proposed method were in good agreement with the 2D MOLLI method both qualitatively and quantitatively. $\textbf{Conclusion:}$ The proposed method allows for free-breathing 3D ECV mapping of the whole heart within a practically feasible imaging time. The estimated ECV values from the proposed method were comparable to those from the existing method. $\textbf{Keywords:}$ cardiac extracellular volume (ECV) mapping, cardiac T1 mapping, linear tangent space alignment (LTSA), manifold learning

physics.med-ph

Point-supervised Brain Tumor Segmentation with Box-prompted MedSAM

Delineating lesions and anatomical structure is important for image-guided interventions. Point-supervised medical image segmentation (PSS) has great potential to alleviate costly expert delineation labeling. However, due to the lack of precise size and boundary guidance, the effectiveness of PSS often falls short of expectations. Although recent vision foundational models, such as the medical segment anything model (MedSAM), have made significant advancements in bounding-box-prompted segmentation, it is not straightforward to utilize point annotation, and is prone to semantic ambiguity. In this preliminary study, we introduce an iterative framework to facilitate semantic-aware point-supervised MedSAM. Specifically, the semantic box-prompt generator (SBPG) module has the capacity to convert the point input into potential pseudo bounding box suggestions, which are explicitly refined by the prototype-based semantic similarity. This is then succeeded by a prompt-guided spatial refinement (PGSR) module that harnesses the exceptional generalizability of MedSAM to infer the segmentation mask, which also updates the box proposal seed in SBPG. Performance can be progressively improved with adequate iterations. We conducted an evaluation on BraTS2018 for the segmentation of whole brain tumors and demonstrated its superior performance compared to traditional PSS methods and on par with box-supervised methods.

cs.CV

Fair Text to Medical Image Diffusion Model with Subgroup Distribution Aligned Tuning

The text to medical image (T2MedI) with latent diffusion model has great potential to alleviate the scarcity of medical imaging data and explore the underlying appearance distribution of lesions in a specific patient status description. However, as the text to nature image models, we show that the T2MedI model can also bias to some subgroups to overlook the minority ones in the training set. In this work, we first build a T2MedI model based on the pre-trained Imagen model, which has the fixed contrastive language-image pre-training (CLIP) text encoder, while its decoder has been fine-tuned on medical images from the Radiology Objects in COntext (ROCO) dataset. Its gender bias is analyzed qualitatively and quantitatively. Toward this issue, we propose to fine-tune the T2MedI toward the target application dataset to align their sensitive subgroups distribution probability. Specifically, the alignment loss for fine-tuning is guided by an off-the-shelf sensitivity-subgroup classifier to match the classification probability between the generated images and the expected target dataset. In addition, the image quality is maintained by a CLIP-consistency regularization term following a knowledge distillation scheme. For evaluation, we set the target dataset to be enhanced as the BraST18 dataset, and trained a brain magnetic resonance (MR) slice-based gender classifier from it. With our method, the generated MR image can markedly reduce the inconsistency with the gender proportion in the BraTS18 dataset.

cs.CV

Nuclear Medicine AI in Action: The Bethesda Report (AI Summit 2024)

The 2nd SNMMI Artificial Intelligence (AI) Summit, organized by the SNMMI AI Task Force, took place in Bethesda, MD, on February 29 - March 1, 2024. Bringing together various community members and stakeholders, and following up on a prior successful 2022 AI Summit, the summit theme was: AI in Action. Six key topics included (i) an overview of prior and ongoing efforts by the AI task force, (ii) emerging needs and tools for computational nuclear oncology, (iii) new frontiers in large language and generative models, (iv) defining the value proposition for the use of AI in nuclear medicine, (v) open science including efforts for data and model repositories, and (vi) issues of reimbursement and funding. The primary efforts, findings, challenges, and next steps are summarized in this manuscript.

physics.med-ph

LeqMod: Adaptable Lesion-Quantification-Consistent Modulation for Deep Learning Low-Count PET Image Denoising

Deep learning-based positron emission tomography (PET) image denoising offers the potential to reduce radiation exposure and scanning time by transforming low-count images into high-count equivalents. However, existing methods typically blur crucial details, leading to inaccurate lesion quantification. This paper proposes a lesion-perceived and quantification-consistent modulation (LeqMod) strategy for enhanced PET image denoising, via employing downstream lesion quantification analysis as auxiliary tools. The LeqMod is a plug-and-play design adaptable to a wide range of model architectures, modulating the sampling and optimization procedures of model training without adding any computational burden to the inference phase. Specifically, the LeqMod consists of two components, the lesion-perceived modulation (LeMod) and the multiscale quantification-consistent modulation (QuMod). The LeMod enhances lesion contrast and visibility by allocating higher sampling weights and stricter loss criteria to lesion-present samples determined by an auxiliary segmentation network than lesion-absent ones. The QuMod further emphasizes quantification accuracy for both the mean and maximum standardized uptake value (SUVmean and SUVmax) across multiscale sub-regions throughout the entire image, thereby reducing biases of denoised results relative to high-count references. Experiments conducted on large PET datasets from multiple centers and vendors, and varying noise levels demonstrated the LeqMod efficacy across various denoising frameworks. Compared to frameworks without LeqMod, the integration of LeqMod reduces the lesion SUVmax bias by 5.92% on average and increases the peak signal-to-noise ratio (PSNR) by 0.36 on average, when denoising images across participating sites.

eess.IV

Treatment-wise Glioblastoma Survival Inference with Multi-parametric Preoperative MRI

In this work, we aim to predict the survival time (ST) of glioblastoma (GBM) patients undergoing different treatments based on preoperative magnetic resonance (MR) scans. The personalized and precise treatment planning can be achieved by comparing the ST of different treatments. It is well established that both the current status of the patient (as represented by the MR scans) and the choice of treatment are the cause of ST. While previous related MR-based glioblastoma ST studies have focused only on the direct mapping of MR scans to ST, they have not included the underlying causal relationship between treatments and ST. To address this limitation, we propose a treatment-conditioned regression model for glioblastoma ST that incorporates treatment information in addition to MR scans. Our approach allows us to effectively utilize the data from all of the treatments in a unified manner, rather than having to train separate models for each of the treatments. Furthermore, treatment can be effectively injected into each convolutional layer through the adaptive instance normalization we employ. We evaluate our framework on the BraTS20 ST prediction task. Three treatment options are considered: Gross Total Resection (GTR), Subtotal Resection (STR), and no resection. The evaluation results demonstrate the effectiveness of injecting the treatment for estimating GBM survival.

cs.CV