Searcharxiv⌕ Search

arXiv subjects

Georgios I. Angelis

Publications and source records attributed to Georgios I. Angelis.

3 recordsLinked to original sources

Bayesian Kinetic Model Selection in Dynamic PET via Consistency Models

Accurate voxel-wise parametric imaging in dynamic positron emission tomography (PET), particu- larly with total-body PET (TB-PET) scanners, requires se- lecting the appropriate kinetic model for diverse organs and lesions. Conventional nonlinear least squares fitting paired with the Akaike or Bayesian Information Criterion (NLS+AIC/BIC) is computationally slow, sensitive to lo- cal minima, and prone to selecting simple models under high voxel-level noise, whereas classical Bayesian methods such as Markov chain Monte Carlo (MCMC) and Approx- imate Bayesian Computation (PET-ABC) are too slow for whole-body imaging. In this work, we propose a consis- tency model (CM) that performs simultaneous Bayesian kinetic model selection and parameter posterior estimation. By combining the continuous kinetic parameters and dis- crete model index into one target vector conditioned on the measured time-activity curve (TAC) and input function, the CM samples from the joint posterior distribution p(θ, m|y) in seconds per slice with a GPU workstation of 4 NVIDIA A100. We validated the framework on two simulated and clinical applications: whole-body [18F]FDG TB-PET across seven compartment models, and brain [11C]raclopride PET for detecting smoking-induced dopamine release between two neurotransmitter models. In simulations, the CM achieved 97.97% model selection accuracy in the [18F]FDG applica- tion (vs. 58.67% for NLS+AIC) and 91.4% accuracy in the [11C]raclopride application (vs. 73.5% for NLS+BIC), while closely matching reference MCMC parameter posteriors. In clinical applications, CM generated whole-body FDG model selection maps, in which each regions was assigned litera- ture established sensible kinetic models; CM also success- fully mapped voxels in the brain where dopamine release was induced by smoking.

physics.med-ph↗

A General-Purpose Adaptable Foundation Model for Total-Body PET Kinetic Modelling

Voxel-level kinetic modeling in total-body dynamic positron emission tomography (TB-PET) enables precise physiological quantification but complicates parameter uncertainty estimation. While generative consistency models (CMs) can rapidly estimate Bayesian posterior distributions, they are constrained by type of tracers, kinetic models, and protocols. Training them from scratch whenever a new tracer, model or protocol is used can be computationally intensive. To address this, we introduce LoRACM, a parameter-efficient framework utilizing low-rank adaptation (LoRA) to transfer a pretrained foundation CM to novel TB-PET scenarios. We evaluated three adaptation scenarios using simulated and human data: scanner and protocol transfer for FDG two-tissue compartment modeling; FP-CIT simplified reference tissue modeling; and high-temporal-resolution FDG blood flow imaging via the adiabatic approximation to tissue homogeneity model. Each adaptation was trained in less than 3 hours on a single NVIDIA A100 GPU using 50,000 simulated pairs. In simulations, LoRACM showed strong agreement with results from Markov Chain Monte Carlo (MCMC, which we use as reference posterior distributions), yielding median Kullback-Leibler divergences of 0.05-0.11 and median absolute percentage errors below 1.2% for each kinetic parameter of interest. In human data, LoRACM generated total-body K_i maps comparable to the ones made by non-negative nonlinear least squares (NNLS) fitting and a consistency model trained from scratch. Striatal dopamine binding potential estimates predicted by LoRACM correlated with NNLS estimates (r = 0.968-0.988). LoRACM produced total-body blood flow imaging with FDG matching the one made by NNLS. These underscore the potential of adapting a pretrained CM with LoRA for fast and reliable posterior parameter inference for kinetic models across distinct TB-PET applications.

physics.med-ph↗

Generative Consistency Models for Estimation of Kinetic Parametric Image Posteriors in Total-Body PET

Dynamic total body positron emission tomography (TB-PET) makes it feasible to measure the kinetics of all organs in the body simultaneously which may lead to important applications in multi-organ disease and systems physiology. Since whole-body kinetics are highly heterogeneous with variable signal-to-noise ratios, parametric images should ideally comprise not only point estimates but also measures of posterior statistical uncertainty. However, standard Bayesian techniques, such as Markov chain Monte Carlo (MCMC), are computationally prohibitive at the total body scale. We introduce a generative consistency model (CM) that generates samples from the posterior distributions of the kinetic model parameters given measured time-activity curves and arterial input function. CM is able to collapse the hundreds of iterations required by standard diffusion models into just 3 denoising steps. When trained on 500,000 physiologically realistic two-tissue compartment model simulations, the CM produces similar accuracy to MCMC (median absolute percent error < 5%; median K-L divergence < 0.5) but is more than five orders of magnitude faster. CM produces more reliable Ki images than the Patlak method by avoiding the assumption of irreversibility, while also offering valuable information on statistical uncertainty of parameter estimates and the underlying model. The proposed framework removes the computational barrier to routine, fully Bayesian parametric imaging in TB-PET and is readily extensible to other tracers and compartment models.

physics.med-ph↗