SearcharxivSearch

arXiv subjects

Gergo Hamar

Publications and source records attributed to Gergo Hamar.

2 recordsLinked to original sources

Novel method for in-situ drift velocity measurement in large volume TPCs: the Geometry Reference Chamber of the NA61/SHINE experiment at CERN

This paper presents a novel method for low maintenance, low ambiguity in-situ drift velocity monitoring in large volume Time Projection Chambers (TPCs). The method was developed and deployed for the 40m^3 TPC tracker system of the NA61/SHINE experiment at CERN, which has a one meter of drift length. The method relies on a low-cost multi-wire proportional chamber placed next to the TPC to be monitored, downstream with respect to the particle flux. Reconstructed tracks in the TPC are matched to hits in the monitoring chamber, called the Geometry Reference Chamber (GRC). Relative differences in positions of hits in the GRC are used to estimate the drift velocity, removing the need for an accurate alignment of the TPC to the GRC. An important design requirement on the GRC was minimal added complexity to the existing system, in particular, compatibility with Front-End Electronics cards already used to read out the TPCs. Moreover, the GRC system was designed to operate both in large and small particle fluxes. The system is capable of monitoring the evolution of the drift velocity inside the TPC down to a one permil precision, with a few minutes of data collection.

physics.ins-det

Single electron multiplication distribution in GEM avalanches

In this paper, measurement results and experimental methodology are presented on the determination of multiplication distributions of avalanches initiated by single electron in GEM foils. The measurement relies on the amplification of photoelectrons by the GEM under study, which is subsequently amplified in an MWPC for signal enhancement and readout. The intrinsic detector resolution, namely the sigma-over-mean ratio of the multiplication. distribution is also elaborated. Small gain dependence of the shape of the avalanche response distribution is observed in the range of net effective gain of 15 to 100. The distribution has an exponentially decaying tail at large amplitudes. At small amplitudes, the applied working gas is seen to have a well visible effect on the shape of the multiplication distribution. Equivalently, the working gas has an influence on the intrinsic detector resolution of GEMs via suppression of the low amplitude responses. A sigma-over-mean ratio of 0.75 was reached using a neon based mixture, whereas other gases provided an intrinsic detector resolution closer to 1, meaning a multiplication distribution closer to the low-field limit exponential case.

physics.ins-det