Searcharxiv⌕ Search

arXiv subjects

Gianluca Geloni

Publications and source records attributed to Gianluca Geloni.

At least 73 records · Page 4Linked to original sources

Circular polarization control for the LCLS baseline in the soft X-ray regime

The LCLS baseline includes a planar undulator system, producing linearly polarized light in the range 0.15-1.5 nm. Polarization control in the soft X-ray region from linear to circular is highly desirable. Several schemes using helical undulators have been discussed for the LCLS. One consists in replacing three of the last planar undulator segments by APPLE III. A second proposal, the 2nd harmonic helical afterburner, uses short, crossed undulators tuned to the second harmonic. This last scheme is expected to be the better one. Its advantages are a high and stable degree of circular polarization and a low cost. Its disadvantage is a small output power and a narrow wavelength range. We propose a novel method to generate 10 GW level power at the fundamental harmonic with 99% degree of circular polarization from the LCLS baseline. Its merits are low cost, simplicity and easy implementation. After the baseline undulator, the electron beam is sent through a 40 m long straight section, and subsequently passes through a short APPLE II radiator. The microbunch structure is easily preserved, and intense coherent radiation is emitted in the helical radiator. The background radiation from the baseline undulator is suppressed by letting radiation and electrons through horizontal and vertical slits upstream the helical radiator, where the radiation spot size is about ten times larger than the electron bunch transverse size. Using thin Beryllium foils for the slits the divergence of the electron beam halo increases by Coulomb scattering, but the beam will propagate through the setup without electron losses. The applicability of our method is not restricted to the LCLS baseline setup. LCLS II or the European XFEL may benefit from this work as well, due to availability of sufficiently long free space at the end of undulator tunnel.

physics.acc-ph↗

Self-seeded operation of the LCLS hard X-ray FEL in the long-bunch mode

Self-seeding options for the LCLS baseline were recently investigated using a scheme which relies on a single-crystal monochromator in Bragg-transmission geometry. The LCLS low-charge (0.02 nC) mode of operation was considered in order to demonstrate the feasibility of the proposed scheme. The wakefield effects from the linac and from the undulator vacuum chamber are much reduced at such low charge, and can be ignored. In this paper we extend our previous investigations to the case of the LCLS mode of operation with nominal charge. Based on the LCLS start-to-end simulation for an electron beam charge of 0.25 nC, and accounting for the wakefields from the undulator vacuum chamber we demonstrate that the same simplest self-seeding system (two undulators with a single-crystal monochromator in between) is appropriate not only for short (few femtosecond) bunches, but for longer bunches too.

physics.acc-ph↗

Generation of doublet spectral lines at self-seeded X-ray FELs

Self-seeding schemes, consisting of two undulators with a monochromator in between, aim to reduce the bandwidth of SASE X-ray FELs. We recently proposed a new method of monochromatization exploiting a single crystal in Bragg-transmission geometry for self-seeding in the hard X-ray range. A straightforward extension is to use such kind of monochromator setup with two -or more- crystals arranged in a series to spectrally filter the SASE radiation at two closely-spaced wavelengths within the FEL gain band. This allows for the production of doublet -or multiplet- spectral lines. Applications involve any process with a large change in cross section over a narrow wavelength range, as in multiple wavelength anomalous diffraction. Here we consider the simultaneous operation of the LCLS hard X-ray FEL at two closely spaced wavelengths. We present simulation results for the LCLS baseline, yielding fully coherent radiation shared between two longitudinal modes. Mode spacing can be easily tuned within the FEL gain band. The XFEL output intensity contains an oscillating "mode-beat" component whose frequency is related to the frequency difference between the pair of longitudinal modes considered. At saturation one obtains FEL-induced modulations of energy loss and energy spread in the electron bunch at optical frequency, which can be converted into density modulation at the same optical frequency using a weak chicane installed behind the baseline undulator. Powerful coherent radiation can then be generated with the help of an optical transition radiation (OTR) station. We also consider how the doublet structure of the XFEL generation spectra can be monitored by an optical spectrometer. The OTR coherent radiation pulse is naturally synchronized with the X-ray pulses, and can be used for timing the XFEL to high power conventional lasers with femtosecond accuracy for pump-probe applications.

physics.acc-ph↗

Way to increase the user access at the LCLS baseline

The LCLS beam is meant for a single user, but the baseline undulator is long enough to serve two users simultaneously. To this end, we propose a setup composed of two elements: an X-ray mirrors pair for X-ray beam deflection, and a 4 m-long magnetic chicane, which creates an offset for mirrors pair installation in the middle of the baseline undulator. The insertable mirrors pair can separate spatially the X-ray beams generated in the first and in the second half of the baseline undulator. Rapid switching of the FEL amplification process allows deactivating one half and activating another half of the undulator. As proposed elsewhere, using a kicker installed upstream of the LCLS baseline undulator and an already existing corrector in the first half of the undulator, it is possible to rapidly switch the X-ray beam from one user to another. We present simulation results for the LCLS baseline, and show that it is possible to generate two saturated SASE X-ray beams in the whole 0.8-8 keV photon energy range in the same baseline undulator. These can serve two users. Our technique does not perturb the baseline mode of operation of the LCLS undulator. Also, the magnetic chicane setup is very flexible, and can be used as a self-seeding setup too. We present simulation results for the LCLS baseline undulator with SHAB. One can produce monochromatic radiation at the 2nd harmonic as well as at the 1st. We describe an efficient way for obtaining multi-user operation at the LCLS hard X-ray FEL. To this end, a photon beam distribution system based on the use of crystals in the Bragg reflection geometry is proposed. The reflectivity of crystal deflectors can be switched fast enough by flipping the crystals with piezoelectric devices. Monochromatic hard X-rays can then be distributed among 6 independent experiments, thereby enabling 6 users to work in parallel in the near and far experimental halls.

physics.acc-ph↗

Cost-effective way to enhance the capabilities of the LCLS baseline

This paper discusses the potential for enhancing the LCLS hard X-ray FEL capabilities. In the hard X-ray regime, a high longitudinal coherence will be the key to such performance upgrade. The method considered here to obtain high longitudinal coherence is based on a novel single-bunch self-seeding scheme exploiting a single crystal monochromator, which is extremely compact and can be straightforwardly installed in the LCLS baseline undulator. We present simulation results dealing with the LCLS hard X-ray FEL, and show that this method can produce fully-coherent X-ray pulses at 100 GW power level. With the radiation beam monochromatized down to the Fourier transform limit, a variety of very different techniques leading to further improvements of the LCLS performance become feasible. In particular, we describe an efficient way for obtaining full polarization control at the LCLS hard X-ray FEL. We also propose to exploit crystals in the Bragg reflection geometry as movable deflectors for the LCLS X-ray transport systems. The hard X-ray beam can be deflected of an angle of order of a radian without perturbations. The monochromatization of the output radiation constitutes the key for reaching such result. Finally, we describe a new optical pump - hard X-ray probe technique which will allow time-resolved studies at the LCLS baseline on the femtosecond time scale. The principle of operation of the proposed scheme is essentially based on the use of the time jitter between pump and probe pulses. This eliminates the need for timing XFELs to high-power conventional lasers with femtosecond accuracy.

physics.acc-ph↗

Scheme for generation of fully-coherent, TW power level hard X-ray pulses from baseline undulators at the European X-ray FEL

The most promising way to increase the output power of an X-ray FEL (XFEL) is by tapering the magnetic field of the undulator. Also, significant increase in power is achievable by starting the FEL process from a monochromatic seed rather than from noise. This report proposes to make use of a cascade self-seeding scheme with wake monochromators in a tunable-gap baseline undulator at the European XFEL to create a source capable of delivering coherent radiation of unprecedented characteristics at hard X-ray wavelengths. Compared with SASE X-ray FEL parameters, the radiation from the new source has three truly unique aspects: complete longitudinal and transverse coherence, and a peak brightness three orders of magnitude higher than what is presently available at LCLS. Additionally, the new source will generate hard X-ray beam at extraordinary peak (TW) and average (kW) power level. The proposed source can thus revolutionize fields like single biomolecule imaging, inelastic scattering and nuclear resonant scattering. The self-seeding scheme with the wake monochromator is extremely compact, and takes almost no cost and time to be implemented. The upgrade proposed in this paper could take place during the commissioning stage of the European XFEL, opening a vast new range of applications from the very beginning of operations. We present feasibility study and examplifications for the SASE2 line of the European XFEL.

physics.acc-ph↗

Cascade self-seeding scheme with wake monochromator for narrow-bandwidth X-ray FELs

Three different approaches have been proposed so far for production of highly monochromatic X-rays from a baseline XFEL undulator: (i) single-bunch self-seeding scheme with a four crystal monochromator in Bragg reflection geometry; (ii) double-bunch self-seeding scheme with a four-crystal monochromator in Bragg reflection geometry; (iii) single-bunch self-seeding scheme with a wake monochromator. A unique element of the X-ray optical design of the last scheme is the monochromatization of X-rays using a single crystal in Bragg-transmission geometry. A great advantage of this method is that the monochromator introduces no path delay of X-rays. This fact eliminates the need for a long electron beam bypass, or for the creation of two precisely separated, identical electron bunches, as required in the other two self-seeding schemes. In its simplest configuration, the self-seeded XFEL consists of an input undulator and an output undulator separated by a monochromator. In some experimental situations this simplest two-undulator configuration is not optimal. The obvious and technically possible extension is to use a setup with three or more undulators separated by monochromators. This amplification-monochromatization cascade scheme is distinguished, in performance, by a small heat-loading of crystals and a high spectral purity of the output radiation. This paper describes such cascade self-seeding scheme with wake monochromators. We present feasibility study and exemplifications for the SASE2 line of the European XFEL.

physics.acc-ph↗

A simple method for controlling the line width of SASE X-ray FELs

This paper describes a novel single-bunch self-seeding scheme for generating highly monochromatic X-rays from a baseline XFEL undulator. Previous schemes made use of a four-crystal fixed-exit monochromator in Bragg geometry. In such monochromator the X-ray pulse acquires a cm-long path delay, which must be compensated. For a single-bunch self-seeding scheme this requires a long electron beam bypass, implying modifications of the baseline undulator configuration. To avoid this problem, a double bunch self-seeding scheme based on a special photoinjector setup was recently proposed. At variance, here we propose a new time-domain method of monochromatization exploiting a single crystal in the transmission direction, thus avoiding the problem of extra-path delay for the X-ray pulse. The method can be realized using a temporal windowing technique, requiring a magnetic delay for the electron bunch only. The proposed setup is extremely simple and composed of as few as two simple elements. These are the crystal and the short magnetic chicane, which accomplishes three tasks by itself. It creates an offset for crystal installation, it removes the electron micro-bunching produced in the first undulator, and it acts as a delay line for temporal windowing. Using a single crystal installed within a short magnetic chicane in the baseline undulator, it is possible to decrease the bandwidth of the radiation well beyond the XFEL design down to 10E-5. The installation of the magnetic chicane does not perturb the undulator focusing system and does not interfere with the baseline mode of operation. We present feasibility study and exemplifications for the SASE2 line of the European XFEL.

physics.acc-ph↗

Scheme for generation of highly monochromatic X-rays from a baseline XFEL undulator

One goal of XFEL facilities is the production of narrow bandwidth X-ray radiation. The self-seeding scheme was proposed to obtain a bandwidth narrower than that achievable with conventional X-ray SASE FELs. A self-seeded FEL is composed of two undulators separated by a monochromator and an electron beam bypass that must compensate for the path delay of X-rays in the monochromator. This leads to a long bypass, with a length in the order of 40-60 m, which requires modifications of the baseline undulator configuration. As an attempt to get around this obstacle, together with a study of the self-seeding scheme for the European XFEL, here we propose a novel technique based on a pulse doubler concept. Using a crystal monochromator installed within a short magnetic chicane in the baseline undulator, it is possible to decrease the bandwidth of the radiation well beyond the XFEL design down to 10^(-5). The magnetic chicane can be installed without any perturbation of the XFEL focusing structure, and does not interfere with the baseline mode of operation. We present a feasibility study and we make exemplifications with the parameters of the SASE2 line of the European XFEL.

physics.acc-ph↗

Control of the amplification process in baseline XFEL undulator with mechanical SASE switchers

The magnetic gap of the baseline XFEL undulators can be varied mechanically for wavelength tuning. In particular, the wavelength range 0.1 nm - 0.4 nm can be covered by operating the European XFEL with the SASE2 undulator. The length of the SASE2 undulator (256.2 m) is sufficient to independently generate three pulses of different radiation wavelengths at saturation. Normally, if a SASE FEL operates in saturation, the quality of the electron beam is too bad for generation of SASE radiation in the subsequent part of undulator which is resonant at a few times longer wavelength. The new method of SASE undulator-switching based on the rapid switching of the FEL amplification process proposed in this paper is an attempt to get around this obstacle. Using mechanical SASE shutters installed within short magnetic chicanes in the baseline undulator, it is possible to rapidly switch the FEL photon beam from one wavelength to another, providing simultaneous multi-color capability. Combining this method with a photon-beam distribution system can provide an efficient way to generate a multi-user facility.

physics.acc-ph↗

Scheme for simultaneous generation of three-color ten GW-level X-ray pulses from baseline XFEL undulator and multi-user distribution system for XFEL laboratory

The baseline design of present XFEL projects only considers the production of a single photon beam at fixed wavelength from each baseline undulator. At variance, the scheme described in this paper considers the simultaneous production of high intensity SASE FEL radiation at three different wavelengths. We present a feasibility study of our scheme, and we make exemplifications with parameters of the baseline SASE2 line of the European XFEL operating in simultaneous mode at 0.05 nm, 0.15 nm and 0.4 nm. Our technique for generating the two colors at 0.05 nm and 0.15 nm is based in essence on a "fresh bunch" technique. For the generation of radiation at 0.4 nm we propose to use an "afterburner" technique. Implementation of these techniques does not perturb the baseline mode of operation of the SASE2 undulator. The present paper also describes an efficient way to obtain a multi-user facility. It is shown that, although the XFEL photon beam from a given undulator is meant for a single user, movable multilayer X-ray mirrors can be used to serve many users simultaneously. The proposed photon beam distribution system would allow to switch the FEL beam quickly between many experiments in order to make an efficient use of the source. Distribution of photons is achieved on the basis of pulse trains and it is possible to distribute the multicolor photon beam among many independent beam lines, thereby enabling many users to work in parallel with different wavelengths.

physics.acc-ph↗

The potential for extending the spectral range accessible to the European XFEL down to 0.05 nm

Specifications of the European XFEL cover a range of wavelengths down to 0.1 nm. The baseline design of the European XFEL assumes standard (SASE) FEL mode for production of radiation i.e. only one photon beam at one fixed wavelength from each baseline undulator with tunable gap. Recent developments in the field of FEL physics and technology form a reliable basis for an extensions of the mode of operation of XFEL facilities. This paper explores how the wavelength of the output radiation can be decreased well beyond the European XFEL design, down to 0.05 nm. In the proposed scheme, which is based on the use "fresh bunch" technique, simultaneous operation at two different wavelengths possible. It is shown that one can generate simultaneously, in the same baseline undulator with tunable gap, high intensity radiation at 0.05 nm at saturation, and high intensity radiation around 0.15 nm according to design specifications. We present a feasibility study and we make exemplifications with the parameters of SASE2 line of the European XFEL.

physics.acc-ph↗

Scheme for femtosecond-resolution pump-probe experiments at XFELs with two-color ten GW-level X-ray pulses

This paper describes a scheme for pump-probe experiments that can be performed at LCLS and at the European XFEL and determines what additional hardware development will be required to bring these experiments to fruition. It is proposed to derive both pump and probe pulses from the same electron bunch, but from different parts of the tunable-gap baseline undulator. This eliminates the need for synchronization and cancels jitter problems. The method has the further advantage to make a wide frequency range accessible at high peak-power and high repetition-rate. An important feature of the proposed scheme is that the hardware requirement is minimal. Our technique is based in essence on the "fresh" bunch technique. For its implementation it is sufficient to substitute a single undulator module with short magnetic delay line, i.e. a weak magnetic chicane, which delays the electron bunch with respect to the SASE pulse of half of the bunch length in the linear stage of amplification. This installation does not perturb the baseline mode of operation. We present a feasibility study and we make exemplifications with the parameters of the SASE2 line of the European XFEL.

physics.acc-ph↗

Ultrafast X-ray pulse measurement method

In this paper we describe a measurement technique capable of resolving femtosecond X-ray pulses from XFEL facilities. Since these ultrashort pulses are themselves the shortest event available, our measurement strategy is to let the X-ray pulse sample itself. Our method relies on the application of a "fresh" bunch technique, which allows for the production of a seeded X-ray pulse with a variable delay between seed and electron bunch. The shot-to-shot averaged energy per pulse is recorded. It turns out that one actually measures the autocorrelation function of the X-ray pulse, which is related in a simple way to the actual pulse width. For implementation of the proposed technique, it is sufficient to substitute a single undulator segment with a short magnetic chicane. The focusing system of the undulator remains untouched, and the installation does not perturb the baseline mode of operation. We present a feasibility study and we make exemplifications with typical parameters of an X-ray FEL.

physics.acc-ph↗

Method for the determination of the three-dimensional structure of ultrashort relativistic electron bunches

We describe a novel technique to characterize ultrashort electron bunches in X-ray Free-Electron Lasers. Namely, we propose to use coherent Optical Transition Radiation to measure three-dimensional (3D) electron density distributions. Our method relies on the combination of two known diagnostics setups, an Optical Replica Synthesizer (ORS) and an Optical Transition Radiation (OTR) imager. Electron bunches are modulated at optical wavelengths in the ORS setup. When these electron bunches pass through a metal foil target, coherent radiation pulses of tens MW power are generated. It is thereafter possible to exploit advantages of coherent imaging techniques, such as direct imaging, diffractive imaging, Fourier holography and their combinations. The proposed method opens up the possibility of real-time, wavelength-limited, single-shot 3D imaging of an ultrashort electron bunch.

physics.optics↗

Theory of edge radiation

We formulate a complete theory of Edge Radiation based on a novel method relying on Fourier Optics techniques. Similar types of radiation like Transition Undulator Radiation are addressed in the framework of the same formalism. Special attention is payed in discussing the validity of approximations upon which the theory is built. Our study makes consistent use of both similarity techniques and comparisons with numerical results from simulation. We discuss both near and far zone. Physical understanding of many asymptotes is discussed. Based on the solution of the field equation with a tensor Green's function technique, we also discuss an analytical model to describe the presence of a vacuum chamber. In particular, explicit calculations for a circular vacuum chamber are reported. Finally, we consider the use of Edge Radiation as a tool for electron beam diagnostics. We discuss Coherent Edge Radiation, Extraction of Edge Radiation by a mirror, and other issues becoming important at high electron energy and long radiation wavelength. Based on this work we also study the impact of Edge Radiation on XFEL setups and we discuss recent results.

physics.acc-ph↗

Transverse coherence properties of X-ray beams in third-generation synchrotron radiation sources

This article describes a complete theory of spatial coherence for undulator radiation sources. Current estimations of coherence properties often assume that undulator sources are quasi-homogeneous, like thermal sources, and rely on the application of the van Cittert-Zernike theorem for calculating the degree of transverse coherence. Such assumption is not adequate when treating third generation light sources, because the vertical(geometrical) emittance of the electron beam is comparable or even much smaller than the radiation wavelength in a very wide spectral interval that spans over four orders of magnitude (from 0.1 Angstrom up to 10^3 Angstrom). Sometimes, the so-called Gaussian-Schell model, that is widely used in statistical optics in the description of partially-coherent sources, is applied as an alternative to the quasi-homogeneous model. However, as we will demonstrate, this model fails to properly describe coherent properties of X-ray beams from non-homogeneous undulator sources. As a result, a more rigorous analysis is required. We propose a technique, based on statistical optics and Fourier optics, to explicitly calculate the cross-spectral density of an undulator source in the most general case, at any position after the undulator. Our theory, that makes consistent use of dimensionless analysis, allows relatively easy treatment and physical understanding of many asymptotes of the parameter space, together with their region of applicability. Particular emphasis is given to the asymptotic situation when the horizontal emittance is much larger than the radiation wavelength, and the vertical emittance is arbitrary. This case is practically relevant for third generation synchrotron radiation sources.

physics.optics↗

A simple method for timing an XFEL source to high-power lasers

We propose a technique, to be used for time-resolved pump-probe experiments, for timing an x-ray free electron laser (XFEL) to a high-power conventional laser with femtosecond accuracy. Our method takes advantage of the same electron bunch to produce both an XFEL pulse and an ultrashort optical pulse with the help of an optical radiator downstream of the x-ray undulator. Since both pulses are produced by the same electron bunch, they are perfectly synchronized. Application of cross-correlation techniques will allow to determine relative jitter between the optical pulse (and, thus, the XFEL pulse) and a pulse from an external pump-laser with femtosecond resolution. Technical realization of the proposed timing scheme uses an optical replica synthesizer (ORS) setup to be installed after the final bunch-compression stage of the XFEL. The electron bunch is modulated in the ORS setup by an external optical laser. Subsequently, it travels through the main undulator, and produces the XFEL pulse. Finally, a powerful optical pulse of coherent edge radiation is generated as the bunch passes through a long straight section and a separation magnet downstream of the main undulator. Our study shows that at a moderate (about 10%) density modulation of the electron bunch at the location of the optical radiator allows production of high power x-ray and optical pulses. Relative synchronization of these pulses is preserved by using the same mechanical support for both x-ray and optical elements transporting radiation down to the experimental area, where single-shot cross-correlation between optical pulse and pump-laser pulse is performed. We illustrate the potential of the proposed timing technique with numerical examples referring to the European XFEL facility.