SearcharxivSearch

arXiv subjects

Giorgio Gratta

Publications and source records attributed to Giorgio Gratta.

At least 19 recordsLinked to original sources

Electric Field Optimization of High-Voltage Vacuum Feedthroughs

We report on the optimization of high voltage vacuum feedthroughs meant to minimize the electric field on the vacuum side of the device. We find that commercial feedthroughs generally have center conductor diameters which are too small, resulting in unnecessarily large fields. We study the problem with analytical calculations and finite element analysis, and present a simple, optimized retrofit for the commercial feedthroughs studied here, without compromising their outgassing properties. This work is important for applications whereby the ``vacuum side'' of the feedthrough is, in fact, filled with a dielectric which may not have the voltage rigidity of vacuum.

physics.ins-det

Large field-of-view, distortion-corrected off-axis parabolic mirror relay microscope

Off-axis parabolic mirrors (OAPs) are occasionally desirable for specialized applications, but are known to introduce field-dependent astigmatic aberrations. In an experiment where optical tweezers are formed by OAPs, another OAP is added to form a relay configuration with an optional microscope, resulting in near diffraction-limited performance, with a resolution of $2.19$ $μm$. The severe radially non-uniform distortion incurred by this configuration, with a long path length and a large field of view, requires software corrections for the microscopic image. To avoid overfitting given the limited features available for calibration at the tweezers focal plane, a distortion model with a reduced set of parameters is selected based on simulation data. Applying the model to experimental data, an average residual error of $3.60$ $μm$ ($1.33$ $μm$) is achieved in object space after the simple relay (adding a $5 \times$ microscope) over a field of approximately $1$ $μm$ $\times$ $1$ $μm$ ($200$ $μm$ $\times$ $200$ $μm$). The residual errors are likely dominated by diffraction artifacts in the features used for correction.

physics.optics

A flexible test facility for liquid xenon detector development

As liquid xenon time projection chambers scale to ever-larger sizes, so too do the engineering challenges they pose. We describe a large, flexible, multipurpose test facility capable of supporting the development of a number of key aspects of liquid xenon detector systems. Example applications of this facility include characterization of large-area light and charge sensor arrays, tests of xenon purification techniques and materials compatibility, and investigations into high-voltage phenomena. This facility uses an automated and remotely monitored cryo-cooling system based on immersion of the test chamber in a liquid bath rather than conductive coupling, leading to advantages in temperature and pressure stability, as well as increasing required response times in the case of cooling-power loss. Design advantages, operational procedures, and performance of the facility are described, as well as five examples of liquid xenon test chambers that use the facility.

physics.ins-det

Coupling of a Nuclear Transition to a Surface Acoustic Wave

Mechanical modulation of recoilless nuclear transitions allows the dynamic control of $\gamma$-ray emission and absorption. Accessing modulation frequencies well above the nuclear linewidth enables coherent manipulation of the nuclear response. Here we demonstrate high frequency control via efficient coupling a film of enriched $^{57}$Fe to a $97.9~\mathrm{MHz}$ surface acoustic wave, nearly two orders of magnitude higher than the nuclear linewidth. The mechanical drive produces a comb of absorption sidebands in the M\"ossbauer spectrum, reflecting the periodic time modulation of the nuclear transitions. This constitutes the highest frequency mechanically driven M\"ossbauer resonance to date. Our solid-state, monolithic platform establishes a new interface between nuclear transitions and high-frequency acoustics, with applications in $\gamma$-ray quantum optics and precision nuclear spectroscopy.

quant-ph

Ion manipulation from liquid Xe to vacuum: Ba-tagging for a nEXO upgrade and future $0 νββ$ experiments

Neutrinoless double beta decay {($0νββ$)} provides a way to probe physics beyond the Standard Model of particle physics. The upcoming nEXO experiment will search for $0νββ$ decay in $^{136}$Xe with a projected half-life sensitivity exceeding $10^{28}$ years at the 90\% confidence level using a liquid xenon (LXe) Time Projection Chamber (TPC) filled with 5 tonnes of Xe enriched to $\sim$90\% in the {$ββ$}-decaying isotope $^{136}$Xe. In parallel, a potential future upgrade to nEXO is being investigated with the aim to further suppress radioactive backgrounds and to confirm $ββ$-decay events. This technique, known as Ba-tagging, comprises extracting and identifying the $ββ$-decay daughter $^{136}$Ba ion. One tagging approach being pursued involves extracting a small volume of LXe in the vicinity of a potential $ββ$-decay using a capillary tube and facilitating a liquid-to-gas phase transition by heating the capillary exit. The Ba ion is then separated from the accompanying Xe gas using a radio-frequency (RF) carpet and RF funnel, conclusively identifying the ion as $^{136}$Ba via laser-fluorescence spectroscopy and mass spectrometry. Simultaneously, an accelerator-driven Ba ion source is being developed to validate and optimize this technique. The motivation for the project, the development of the different aspects, along with the current status and results, are discussed here.

physics.ins-det

Optomechanical vector sensing of new forces at 6 micron separation

The search for new gravity-like interactions at the sub-millimeter scale is a compelling area of research, with important implications for the understanding of classical gravity and its connections with quantum physics. We report improved constraints on Yukawa-type interactions in the $10\,\mathrm{\mu m}$ regime using optically levitated dielectric microspheres as test masses. The search is performed, for the first time, sensing multiple spatial components of the force vector, and with sensitivity improved by a factor of $\sim 100$ with respect to previous measurements using the same technique. The resulting upper limit on the strength of a hypothetical new force is $10^7$ at a Yukawa range $\lambda\simeq 5\;\mu$m and close to $10^6$ for $\lambda \gtrsim 10\;\mu$m. This result also advances our efforts to measure gravitational effects using micrometer-size objects, with important implications for embryonic ideas to investigate the quantum nature of gravity.

hep-ex

Platinum Black for stray-light mitigation on high-aspect-ratio micromechanical cantilever

Microscopic devices are widely used in optomechanical experiments at the cutting-edge of precision experimental physics. Such devices often need to have high electrical conductivity but low reflectivity at optical wavelengths, which can be competing requirements for many commonly available coatings. In this manuscript, we present a technique to electroplate platinum with a highly convoluted surface on a $475\,\mathrm{μm } \, \times 500\,\mathrm{μm } \, \times 10\,\mathrm{μm }$ Silicon/Gold cantilever, preserving its electrical conductivity but reducing its reflectivity in the $0.3 - 1\,\mathrm{μm}$ range by a factor of $100$ or greater. The fact that the deposition can be done post-fabrication without damaging delicate structures makes this technique of interest to a potentially large range of experimental applications.

physics.optics

Detecting Nanometer-Scale New Forces with Coherent Neutron Scattering

Significant effort has been devoted to searching for new fundamental forces of nature. At short length scales (below approximately 10 nm), the strongest experimental constraints come from neutron scattering from individual nuclei in gases. The leading experiments at longer length scales instead measure forces between macroscopic test masses. We propose a hybrid of these two approaches: scattering neutrons off of a target that has spatial structure at nanoscopic length scales. Such structures will give a coherent enhancement to small-angle scattering, where the new force is most significant. This can considerably improve the sensitivity of neutron scattering experiments for new forces in the 0.1 - 100 nm range. We discuss the backgrounds due to Standard Model interactions and a variety of potential target structures that could be used, estimating the resulting sensitivities. We show that, using only one day of beam time at a modern neutron scattering facility, our proposal has the potential to detect new forces as much as two orders of magnitude beyond current laboratory constraints at the appropriate length scales.

hep-ph

Librational Feedback Cooling

Librational motion, whereby a rigid body undergoes angular oscillation around a preferred direction, can be observed in optically trapped, silica microspheres. We demonstrate the cooling of one librational degree of freedom for $\sim 5~μ$m diameter spheres that have been induced to rotate with an external electric field coupled to their electric dipole moment. Cooling is accomplished by adding a phase modulation to the rotating field. The degree of cooling is quantified by applying a $π/2$ shift to the phase of the electric field and fitting the resulting exponential decay of the librational motion to obtain a damping time, as well as estimating a mode temperature from the observed libration in equilibrium. The result is an important step in the study of the dynamics of trapped microspheres, crucial to cooling the mechanical motion to its ground state, as well as providing insights regarding the charge mobility in the material at microscopic scales.

physics.optics

A background-free optically levitated charge sensor

Optically levitated macroscopic objects are a powerful tool in the field of force sensing, owing to high sensitivity, absolute force calibration, environmental isolation and the advanced degree of control over their dynamics that have been achieved. However, limitations arise from the spurious forces caused by electrical polarization effects that, even for nominally neutral objects, affect the force sensing because of the interaction of dipole moments with gradients of external electric fields. In this paper we introduce a new technique to model and eliminate dipole moment interactions limiting the performance of sensors employing levitated objects. This process leads to the first noise-limited measurement with a sensitivity of $3.3\times10^{-5}e$. As a demonstration, this is applied to the search for unknown charges of a magnitude much below that of an electron or for exceedingly small unbalances between electron and proton charges. The absence of remaining systematic biases, enables true discovery experiments, with sensitivities that are expected to improve as the system noise is brought down to or beyond the quantum limit. As a by-product of the technique, the electromagnetic properties of the levitated objects can also be measured on an individual basis.

hep-ex

Search for non-Newtonian interactions at micrometer scale with a levitated test mass

We report on a search for non-Newtonian forces that couple to mass, with a characteristic scale of ${\sim}10~μ$m, using an optically levitated microsphere as a precision force sensor. A silica microsphere trapped in an upward-propagating, single-beam, optical tweezer is utilized to probe for interactions sourced from a nanofabricated attractor mass with a density modulation brought into close proximity to the microsphere and driven along the axis of periodic density in order to excite an oscillating response. We obtain force sensitivity of ${\lesssim}10^{-16}~\rm{N}/\sqrt{\rm{Hz}}$. Separately searching for attractive and repulsive forces results in the constraint on a new Yukawa interaction of $|α| \gtrsim 10^8$ for $λ> 10~μ$m. This is the first test of the inverse-square law using an optically levitated test mass of dimensions comparable to $λ$, a complementary method subject to a different set of systematic effects compared to more established techniques.

hep-ex

Measurement of the Ionization Yield of Neutron-Induced Proton Recoils in Tetramethylsilane

We report on a low energy measurement of the ionization yield in a Tetramethylsilane Time Projection Chamber (TPC) using 2.8 MeV neutrons from a deuterium-deuterium neutron generator. The proton recoil charge yield is measured at four different electric fields, finding a dependence that is well described by the Thomas-Imel model. By comparing the proton recoil yield to that obtained from $γ$-ray calibrations, a quenching factor is obtained for each electric field. These results demonstrate the feasibility of using room temperature organic ionisation detectors to detect MeV-scale neutrons in the proton-recoil channel.

hep-ex

Searching for New Interactions at Sub-micron Scale Using the Mossbauer Effect

A new technique to search for new scalar and tensor interactions at the sub-micrometer scale is presented. The technique relies on small shifts of nuclear gamma lines produced by the coupling between matter and the nuclei in the source or absorber of a Mossbauer spectrometer. Remarkably, such energy shifts are rather insensitive to electromagnetic interactions that represent the largest background in searches for new forces using atomic matter. This is because nuclei are intrinsically shielded by the electron clouds. Additionally, electromagnetic interactions cause energy shifts by coupling to nuclear moments that are suppressed by the size of the nuclei, while new scalar interactions can directly affect these shifts. Finally, averaging over unpolarized nuclei, further reduces electromagnetic interactions. We discuss several possible configurations, using the traditional Mossbauer effect as well as nuclear resonant absorption driven by synchrotron radiation. For this purpose, we examine the viability of well known Mossbauer nuclides along with more exotic ones that result in substantially narrower resonances. We find that the technique introduced here could substantially improve the sensitivity to a variety of new interactions and could also be used, in conjunction with mechanical force measurements, to corroborate a discovery or explore the new physics that may be behind a discovery.

hep-ph

High sensitivity, levitated microsphere apparatus for short-distance force measurements

A high sensitivity force sensor based on dielectric microspheres in vacuum, optically trapped by a single, upward-propagating laser beam, is described. Off-axis parabolic mirrors are used both to focus the 1064~nm trapping beam and to recollimate it to provide information on the horizontal position of the microsphere. The vertical degree of freedom is readout by forming an interferometer between the light retroreflected by the microsphere and a reference beam, hence eliminating the need for auxiliary beams. The focus of the trapping beam has a 1/e$^2$ radius of 3.2~$μ$m and small non-Gaussian tails, suitable for bringing devices close to the trapped microsphere without disturbing the optical field. Electrodes surrounding the trapping region provide excellent control of the electric field, which can be used to drive the translational degrees of freedom of a charged microsphere and the rotational degrees of freedom of a neutral microsphere, coupling to its electric dipole moment. With this control, the charge state can be determined with single electron precision, the mass of individual microspheres can be measured, and empirical calibrations of the force sensitivity can be made for each microsphere. A force noise of $<1\times10^{-17}$~N/$\sqrt{\rm Hz}$, which is comparable to previous reports, is measured on all three degrees of freedom for 4.7~$μ$m diameter, 84~pg silica microspheres. Various devices have been brought within $1.6~μ$m of the surface of a trapped microsphere. Metrology in the trapping region is provided by two custom-designed microscopes providing views in the horizontal and one of the vertical planes. The apparatus opens the way to performing high sensitivity three-dimensional force measurements at short distance.

physics.ins-det

A Tetramethylsilane TPC with Cherenkov light readout and 3D reconstruction

We describe the construction and calibration of a multi-channel liquid time projection chamber filled with Tetramethylsilane (TMS). Its charge readout system consists of 8 wires each in the $X$ and $Y$ directions. The chamber is also equipped with a Cherenkov light readout system consisting of a 5-inch photomultiplier tube (PMT) coupled to the liquid volume through a viewport. The energy scale of the detector is calibrated using positron-electron pairs produced by 4.4 MeV gamma rays emitted from an AmBe source, using an external trigger on the positron annihilation gammas. The external trigger is then reconfigured to tag cosmic ray muons passing through the active TMS volume, which are used to measure the stopping power in TMS and the electron lifetime in the detector. We find a most-probable energy loss from minimum ionising particles (MIPs) of $Δ_p/ds$ = (0.60$\pm$0.01) MeV/cm. We also derive an electron lifetime of 43$^{+680}_{-21}~μ$s by measuring the most-probable energy loss as a function of drift time. For both fast electron and muon signals, the PMT detects prompt Cherenkov light, demonstrating the possibility of random triggering. The room-temperature organic target medium, together with the self-triggering capabilities and long electron lifetimes reported in this work, make this an attractive technology to further explore for rare event detectors or other applications in the area of radiation measurements.

physics.ins-det

Quantum Detection using Magnetic Avalanches in Single-Molecule Magnets

The detection of a single quantum of energy with high efficiency and low false positive rate is of considerable scientific interest, from serving as single quantum sensors of optical and infra-red photons to enabling the direct detection of low-mass dark matter. We report the first experimental demonstration of magnetic avalanches induced by scattering of quanta in single-molecule magnet (SMM) crystals made of Mn12-acetate, establishing the use of SMMs as particle detectors for the first time. While the current setup has an energy threshold in the MeV regime, our results motivate the exploration of a wide variety of SMMs whose properties could allow for detection of sub-eV energy depositions.

physics.ins-det

Absolute pressure and gas species identification with an optically levitated rotor

The authors describe a novel variety of spinning-rotor vacuum gauge in which the rotor is a ${\sim}4.7{\text -}μ$m-diameter silica microsphere, optically levitated. A rotating electrostatic field is used to apply torque to the permanent electric dipole moment of the silica microsphere and control its rotational degrees of freedom. When released from a driving field, the microsphere's angular velocity decays exponentially with a damping time inversely proportional to the residual gas pressure, and dependent on gas composition. The gauge is calibrated by measuring the rotor mass with electrostatic co-levitation, and assuming a spherical shape, confirmed separately, and uniform density. The gauge is cross-checked against a capacitance manometer by observing the torsional drag due to a number of different gas species. The techniques presented can be used to perform absolute vacuum measurements localized in space, owing to the small dimensions of the microsphere and the ability to translate the optical trap in three dimensions, as well as measurements in magnetic field environments. In addition, the dynamics of the microsphere, paired with a calibrated vacuum gauge, can be used to measure the effective molecular mass of a gas mixture without the need for ionization and at pressures up to approximately 1 mbar.

physics.ins-det

Precision Mass and Density Measurement of Individual Optically Levitated Microspheres

We report an $\textit{in situ}$ mass measurement of approximately-$4.7{\text -}μ$m-diameter, optically levitated microspheres with an electrostatic co-levitation technique. The mass of a trapped, charged microsphere is measured by holding its axial (vertical) position fixed with an optical feedback force, under the influence of a known electrostatic force. A mass measurement with $1.8\%$ systematic uncertainty is obtained by extrapolating to the electrostatic force required to support the microsphere against gravity in the absence of optical power. In three cases, the microspheres are recovered from the trap on a polymer-coated silicon beam and imaged with an electron microscope to measure their radii. The simultaneous precision characterization of the mass and radius of individual microspheres implies a density of $1.55\pm0.08~$g/cm$^3$. The ability to recover individual microspheres from an optical trap opens the door to further diagnostics.

physics.ins-det