SearcharxivSearch

arXiv subjects

Giovanni Gallucci

Publications and source records attributed to Giovanni Gallucci.

3 recordsLinked to original sources

Letter Of Intent for a future $\mu^+ \to \mathrm{e}^+ \gamma$ experiment at the High Intensity Muon Beam facility at PSI

Searches for charged lepton flavor violation in the muon sector stand out among the most sensitive and clean probes for physics beyond the Standard Model. Currently, $\mu^+ \to \mathrm{e}^+ \gamma$ experiments provide the best constraints in this field for a wide range of models while, in the coming years, new experiments investigating the processes of $\mu^+ \to \mathrm{e}^+ \mathrm{e}^+ \mathrm{e}^-$ and $\mu \to \mathrm{e}$ conversion in the nuclear field are anticipated to reach comparable or higher sensitivities. The High-Intensity Muon Beam (HIMB) facility at PSI, which is expected to deliver muon beam intensities up to two orders of magnitude higher than the existing beam lines, offers a unique opportunity to significantly enhance the sensitivity of $\mu^+ \to \mathrm{e}^+ \gamma$ searches. The discovery potential could be substantially boosted and a sensitivity comparable to that of all the other projects could be reestablished, which is essential for discriminating among competing new-physics scenarios should an observation occur in any of the channels. In this document, we express our interest in developing a $\mu^+ \to \mathrm{e}^+ \gamma$ experimental program at HIMB, with the goal of improving, within the next decade, the sensitivity of the $\mu^+ \to \mathrm{e}^+ \gamma$ search by more than one order of magnitude relative to the expected final result of the current leading experiment, MEG II. This effort would ensure that PSI retains its leadership in this field.

hep-ex

The Search for $μ^+\to e^+ γ$ with 10$^{-14}$ Sensitivity: the Upgrade of the MEG Experiment

The MEG experiment took data at the Paul Scherrer Institute in the years 2009--2013 to test the violation of the lepton flavour conservation law, which originates from an accidental symmetry that the Standard Model of elementary particle physics has, and published the most stringent limit on the charged lepton flavour violating decay $μ^+ \rightarrow {\rm e}^+ γ$: BR($μ^+ \rightarrow {\rm e}^+ γ$) $<4.2 \times 10^{-13}$ at 90% confidence level. The MEG detector has been upgraded in order to reach a sensitivity of $6\times10^{-14}$. The basic principle of MEG II is to achieve the highest possible sensitivity using the full muon beam intensity at the Paul Scherrer Institute ($7\times10^{7}$ muons/s) with an upgraded detector. The main improvements are better rate capability of all sub-detectors and improved resolutions while keeping the same detector concept. In this paper, we present the current status of the preparation, integration and commissioning of the MEG II detector in the recent engineering runs.

hep-ex

The Cryogenic Anticoincidence Detector for ATHENA X-IFU: Preliminary test of AC-S9 towards the Demonstration Model

Our team is developing the Cryogenic Anticoincidence Detector (CryoAC) of the ATHENA X-ray Integral Field Unit (X-IFU). It is a 4-pixels TES-based detector, which will be placed less than 1 mm below the main TES array detector. We are now producing the CryoAC Demonstration Model (DM): a single pixel prototype able to probe the detector critical technologies, i.e. the operation at 50 mK thermal bath, the threshold energy at 20 keV and the reproducibility of the thermal conductance between the suspended absorber and the thermal bath. This detector will be integrated and tested in our cryogenic setup at INAF/IAPS, and then delivered to SRON for the integration in the X-IFU Focal Plane Assemby (FPA) DM. In this paper we report the status of the CryoAC DM development, showing the main result obtained with the last developed prototype, namely AC-S9. This is a DM-like sample, which we have preliminary integrated and tested before performing the final etching process to suspend the silicon absorber. The results are promising for the DM, since despite the limitations due to the absence of the final etching (high thermal capacity, high thermal conductance, partial TES surface coverage), we have been able to operate the detector with TB = 50 mK and to detect 6 keV photons, thus having a low energy threshold fully compatible with our requirement (20 keV).

astro-ph.IM