SearcharxivSearch

arXiv subjects

Giovanni Pinaroli

Publications and source records attributed to Giovanni Pinaroli.

4 recordsLinked to original sources

Gain characterization of LGAD sensors with beta particles and 28-MeV protons

Low Gain Avalanche Diodes, also known as LGADs, are widely considered for fast-timing applications in high energy physics, nuclear physics, space science, medical imaging, and precision measurements of rare processes. Such devices are silicon-based and feature an intrinsic gain due to a $p{^+}$-doped layer that allows the production of a controlled avalanche of carriers, with multiplication on the order of 10-100. This technology can provide time resolution on the order of 20-30 ps, and variants of this technology can provide precision tracking too. The characterization of LGAD performance has so far primarily been focused on the interaction of minimum ionizing particles for high energy and nuclear physics applications. This article expands the study of LGAD performance to highly-ionizing particles, such as 28-MeV protons, which are relevant for several future scientific applications, e.g. in biology and medical physics, among others. These studies were performed with a beam of 28-MeV protons from a tandem Van de Graaff accelerator at Brookhaven National Laboratory and beta particles from a $^{90}{\rm Sr}$ source; these were used to characterize the response and the gain of an LGAD as a function of bias voltage and collected charge. The experimental results are also compared to TCAD simulations.

physics.ins-det

Evaluation of a Full Field Fluorescence Imager with Synchrotron Radiation

The design and evaluation on the NSLS-II beamline of the 3FI application specific integrated circuit (ASIC) bump-bonded to a simply, planar, two-dimensionally segmented silicon sensor is presented. The ASIC was developed for Full-Field Fluorescence spectral X-ray Imaging (3FI). It is a small-scale prototype that features a square array of 32x32 pixels with a pitch of 100 μm. The ASIC was implemented in a 65 nm CMOS process. Each pixel incorporates a charge-sensitive amplifier, shaping filter, discriminator, peak detector, and sample-and-hold circuit, allowing detection of events and storing signal amplitudes. The system operates in an event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence imaging. At power consumption of 200 μW per pixel, consisting almost uniquely of power dissipated in analog blocks, 308 eV full width at half maximum (FWHM) energy resolution at 8.04 keV, that corresponds to 30 e- rms equivalent noise charge (ENC) and 138 eV FWHM energy resolution at 3.69 keV (16 e- rms ENC) were obtained, for Cu and Ca Kα lines, respectively. Each pixel operates independently, and the detector enables in situ trace element microanalysis in biological and environmental research. Its architecture addresses limitations of X-ray Fluorescence Microscopy (XFM), typically requiring mechanical scanning, by offering frame-lees data acquisition, translating to high-throughput operation. The 3FI ASIC is suitable for example for studies of nutrient cycling in the (mycor)rhizosphere, microbial redox processes, and genotype-phenotype correlations in bio-energy crops. Additional performances, such as enhanced spatial resolution can be further improved with coded-aperture and Wolt, extending the use to environmental, biomedical, and material science studies.

physics.ins-det

A Virtual Frisch-Grid Geometry-Based CZT Gamma Detector for In-Field Radioisotope Identification

We present a Virtual Frisch-Grid geometry-based CZT gamma detector developed for identifying different radioisotopes over an energy range from single keV up to 2 MeV, and useful for efficient characterization of CZT crystals. The detector is built with a 3 x 3 matrix of CZT crystals, each measuring approximately 6 mm x 6 mm x 15 mm. The charge generated within the sensor's active volume is read out via an anode connected directly to the AVG3_Dev integrated circuit. A current signal induced by charge drift is collected on side pads of the crystals, enabling reconstruction of a 3D interaction position. This paper discusses the design, development, and performance of the standalone, mobile detector system, which integrates the AVG3_Dev readout IC developed at Brookhaven National Laboratory, high-speed FPGA-based with per-channel digital signal processing, and embedded system capabilities. The device is compact, battery-powered, and supports wireless data streaming, making it suitable for field operations towards radioisotope identification.

physics.ins-det

Monolithic Active Pixel Sensors on CMOS technologies

Collider detectors have taken advantage of the resolution and accuracy of silicon detectors for at least four decades. Future colliders will need large areas of silicon sensors for low mass trackers and sampling calorimetry. Monolithic Active Pixel Sensors (MAPS), in which Si diodes and readout circuitry are combined in the same pixels, and can be fabricated in some of standard CMOS processes, are a promising technology for high-granularity and light detectors. In this paper we review 1) the requirements on MAPS for trackers and electromagnetic calorimeters (ECal) at future colliders experiments, 2) the ongoing efforts towards dedicated MAPS for the Electron-Ion Collider (EIC) at BNL, for which the EIC Silicon Consortium was already instantiated, and 3) space-born applications for MeV $γ$-ray experiments with MAPS based trackers (AstroPix).

physics.ins-det