SearcharxivSearch

arXiv subjects

Giulia Zanini

Publications and source records attributed to Giulia Zanini.

2 recordsLinked to original sources

Optical Measurement of Mass Density of Biological Samples

Mass density is a vital property for improved biophysical understanding of and within biological samples. It is increasingly attracting active investigation, but still lacks reliable, non-contact techniques to accurately characterize it in biological systems. Contrary to popular belief, refractive index information alone is insufficient to determine a sample's mass density, as we demonstrate here theoretically and experimentally. Instead, we measured the nonlinear gain of stimulated Brillouin scattering to provide additional information for mass density estimation. This all-optical method reduces the estimation error tenfold, offering a more accurate and universal technique for mass density measurements.

cond-mat.soft

Electro-Optic Modulator source as sample-free calibrator and frequency stabilizer for Brillouin Microscopy

Brillouin Microscopy is a novel label-free optical technique that enables the measurement of a material's mechanical properties at the sub-micron scale in a non-invasive and non-contact way; in the last few years, its applications in the life sciences have extensively expanded. To date, many custom-built Brillouin Microscopes suffer from temporal instabilities that impact their performances, showing drifts in the acquired spectra during time that may lead to inconsistencies between data acquired at different days. A further challenge for standard Brillouin Microscopes is the calibration of the spectrometer: the currently accepted protocol in literature uses known Brillouin shifts of water and methanol to reconstruct the dispersion curve, but this approach is highly influenced by external factors that are unrelated to spectrometer's performances. Manual and frequent realignments of the spectrometer and repeated calibrations with standard materials are thus needed to address these issues. Here, we show an innovative method to remove temporal instabilities of a standard Brillouin Microscope by inserting an Electro-Optic Modulator (EOM) that can be used: i) as a reference signal during measurements; ii) as a calibrator, allowing the reconstruction of the spectrometer dispersion curve with high precision, in an automatic pipeline and without the need for reference samples; iii) as a tool to detect and compensate for temporal drifts through a feedback control in a closed loop. We here show that our Brillouin Microscope, equipped with an EOM and a tuneable laser, is able to automatically acquire data for more than 2 days without the need to realign the spectrometer; retrieved Brillouin shifts and widths showed superior stability in time than standard Brillouin Microscopes.

physics.bio-ph