SearcharxivSearch

arXiv subjects

Gopalakrishnan Balasubramanian

Publications and source records attributed to Gopalakrishnan Balasubramanian.

10 recordsLinked to original sources

Single-Spin Nitrogen-Vacancy Magnetometer with Enhanced Static Field Sensitivity

Precision sensing and imaging of weak static magnetic fields are crucial for a variety of emerging nanoscale applications. While nitrogen-vacancy (NV) centers in diamond provide exceptional AC magnetic field sensitivity with nanoscale spatial resolution, their sensitivity to static (DC) magnetic fields is fundamentally limited by the short dephasing time (T2*) due to spin-spin interactions. In this work, we present a novel hybrid sensing approach that integrates a soft ferromagnetic microwire with a single near-surface NV center to amplify its response to external static magnetic fields. This hybrid configuration achieves a DC magnetic field sensitivity of 63 nT/sqrt(Hz) for a single NV center - about 500 times greater than conventional inhomogeneous broadening- or T2*-limited magnetometry, with potential for further enhancement. The compact and highly sensitive nature of this sensor opens new opportunities for quantum sensing applications involving the detection of static or slowly varying magnetic fields across diverse scientific and technological domains.

quant-ph

Magnetic sensing at zero field with a single nitrogen-vacancy center

Single nitrogen-vacancy (NV) centers are widely used as nanoscale sensors for magnetic and electric fields, strain and temperature. Nanoscale magnetometry using NV centers allows for example to quantitatively measure local magnetic fields produced by vortices in superconductors, topological spin textures such as skyrmions, as well as to detect nuclear magnetic resonance signals. However one drawback when used as magnetic field sensor has been that an external bias field is required to perform magnetometry with NV centers. In this work we demonstrate a technique which allows access to a regime where no external bias field is needed. This enables new applications in which this bias field might disturb the system under investigation. Furthermore, we show that our technique is sensitive enough to detect spins outside of the diamond which enables nanoscale zero- to ultralow-field nuclear magnetic resonance.

physics.atom-ph

Tapered ultra-high Numerical Aperture optical fiber tip for Nitrogen Vacancy ensembles based endoscope in a fluidic environment

Fixing a diamond containing a high density of Nitrogen-Vacancy (NV) center ensembles on the apex of a multimode optical fiber (MMF) extends the applications of NV-based endoscope sensors. Replacing the normal MMF with a tapered MMF (MMF-taper) has enhanced the fluorescence (FL) collection efficiency from the diamond and achieved a high spatial resolution NV-based endoscope. The MMF-taper's high FL collection efficiency is the direct result of multiple internal reflections in the tapered region caused by silica, which has a higher refractive index (RI) than the surrounding air. However, for applications involving fluidic environments whose RI is close to or higher than that of the silica, the MMF-taper loses its FL collection significantly. Here, to overcome this challenge, we replaced the MMF-taper with an ultra-high numerical aperture (NA) microstructured optical fiber (MOF) which is tapered and sealed its air capillaries at the tapered end. Since the end-sealed air capillaries along the tapered MOF (MOF-taper) have isolated the MOF core from the surrounding medium, the core retains its high FL collection and NV excitation efficiency in liquids regardless of their RI values. Such a versatile NV-based endoscope could potentially find broad applications in fluidic environments where many biological processes and chemical reactions occur.

physics.app-ph

Efficient nitrogen-vacancy centers' fluorescence excitation and collection from micrometer-sized diamond by a tapered optical fiber

Efficiently excite nitrogen-vacancy (NV) centers in diamond and collect their fluorescence significantly benefit the fiber-optic-based NV sensors. Here, using a tapered optical fiber (TOF) tip, we significantly improve the efficiency of the laser excitation and fluorescence collection of the NV, thus enhance the sensitivity of the fiber-optic based micron-sized diamond magnetic sensor. Numerical calculation shows that the TOF tip delivers a high numerical aperture (NA) and has a high fluorescence excitation and collection efficiency. Experiments demonstrate that using such TOF tip can obtain up to over 7-fold the fluorescence excitation efficiency and over15-fold the fluorescence collection efficiency of a flat-ended (non-TOF) fiber. Such fluorescence collection enhances the sensitivity of the optical fiber-based diamond NV magnetometer, thus extending its potential application region.

physics.app-ph

Enhancing fluorescence excitation and collection from the nitrogen-vacancy center in diamond through a micro-concave mirror

We experimentally demonstrate a simple and robust optical fibers based method to achieve simultaneously efficient excitation and fluorescence collection from Nitrogen-Vacancy (NV) defects containing micro-crystalline diamond. We fabricate a suitable micro-concave (MC) mirror that focuses scattered excitation laser light into the diamond located at the focal point of the mirror. At the same instance, the mirror also couples the fluorescence light exiting out of the diamond crystal in the opposite direction of the optical fiber back into the optical fiber within its light acceptance cone. This part of fluorescence would have been otherwise lost from reaching the detector. Our proof-of-principle demonstration achieves a 25 times improvement in fluorescence collection compared to the case of not using any mirrors. The increase in light collection favors getting high signal-to-noise ratio (SNR) optically detected magnetic resonance (ODMR) signals hence offers a practical advantage in fiber-based NV quantum sensors. Additionally, we compacted the NV sensor system by replacing some bulky optical elements in the optical path with a 1x2 fiber optical coupler in our optical system. This reduces the complexity of the system and provides portability and robustness needed for applications like magnetic endoscopy and remote-magnetic sensing.

physics.app-ph

Dynamical sensitivity control of a single-spin quantum sensor

The Nitrogen-Vacancy (NV) defect in diamond is a unique quantum system that offers precision sensing of nanoscale physical quantities beyond the current state-of-the-art. Here we present a method to controllably encode the interactions in the population of the spin states, thereby introducing a way to control the sensitivity of a single spin as a continuum in contrast to free-evolution based methods. By adopting this feature we demonstrate high-accuracy NV magnetometry without 2pi ambiguities, enhance the dynamic range by a factor of 4*10^3 achieve interaction times exceeding 2 ms in off-the-shelf diamond. We perform nuclear spin-noise spectroscopy in the frequency domain by dynamically controlling the NV spin's sensitivity piecewise and in a smooth manner thereby precluding harmonic artefacts and undesired interactions. On a broader perspective dynamical sensitivity control provides an elegant handle on the inherent dynamics of quantum systems, while offering decisive advantages for NV centre applications notably in quantum controls and single molecule NMR/MRI.

quant-ph

A nitrogen-vacancy spin based molecular structure microscope using multiplexed projection reconstruction

Methods and techniques to measure and image beyond the state-of-the-art have always been influential in propelling basic science and technology. Because current technologies are venturing into nanoscopic and molecular-scale fabrication, atomic-scale measurement techniques are inevitable. One such emerging sensing method uses the spins associated with nitrogen-vacancy (NV) defects in diamond. The uniqueness of this NV sensor is its atomic size and ability to perform precision sensing under ambient conditions conveniently using light and microwaves (MW). These advantages have unique applications in nanoscale sensing and imaging of magnetic fields from nuclear spins in single biomolecules. During the last few years, several encouraging results have emerged towards the realization of an NV spin-based molecular structure microscope. Here, we present a projection-reconstruction method that retrieves the three-dimensional structure of a single molecule from the nuclear spin noise signatures. We validate this method using numerical simulations and reconstruct the structure of a molecular phantom \b{eta}-cyclodextrin, revealing the characteristic toroidal shape.

quant-ph

Sensing electric fields using single diamond spins

The ability to sensitively detect charges under ambient conditions would be a fascinating new tool benefitting a wide range of researchers across disciplines. However, most current techniques are limited to low-temperature methods like single-electron transistors (SET), single-electron electrostatic force microscopy and scanning tunnelling microscopy. Here we open up a new quantum metrology technique demonstrating precision electric field measurement using a single nitrogen-vacancy defect centre(NV) spin in diamond. An AC electric field sensitivity reaching ~ 140V/cm/\surd Hz has been achieved. This corresponds to the electric field produced by a single elementary charge located at a distance of ~ 150 nm from our spin sensor with averaging for one second. By careful analysis of the electronic structure of the defect centre, we show how an applied magnetic field influences the electric field sensing properties. By this we demonstrate that diamond defect centre spins can be switched between electric and magnetic field sensing modes and identify suitable parameter ranges for both detector schemes. By combining magnetic and electric field sensitivity, nanoscale detection and ambient operation our study opens up new frontiers in imaging and sensing applications ranging from material science to bioimaging.

quant-ph

Sub-optical resolution of single spins using magnetic resonance imaging at room temperature in diamond

There has been much recent interest in extending the technique of magnetic resonance imaging (MRI) down to the level of single spins with sub-optical wavelength resolution. However, the signal to noise ratio for images of individual spins is usually low and this necessitates long acquisition times and low temperatures to achieve high resolution. An exception to this is the nitrogen-vacancy (NV) color center in diamond whose spin state can be detected optically at room temperature. Here we apply MRI to magnetically equivalent NV spins in order to resolve them with resolution well below the optical wavelength of the readout light. In addition, using a microwave version of MRI we achieved a resolution that is 1/270 size of the coplanar striplines, which define the effective wavelength of the microwaves that were used to excite the transition. This technique can eventually be extended to imaging of large numbers of NVs in a confocal spot and possibly to image nearby dark spins via their mutual magnetic interaction with the NV spin.

quant-ph

High sensitivity magnetic imaging using an array of spins in diamond

We present a solid state magnetic field imaging technique using a two dimensional array of spins in diamond. The magnetic sensing spin array is made of nitrogen-vacancy (NV) centers created at shallow depths. Their optical response is used for measuring external magnetic fields in close proximity. Optically detected magnetic resonance (ODMR) is readout from a 60x60 $μ$m field of view in a multiplexed manner using a CCD camera. We experimentally demonstrate full two-dimensional vector imaging of the magnetic field produced by a pair of current carrying micro-wires. The presented widefield NV magnetometer offers in addition to its high magnetic sensitivity of 20 nT/$\sqrt{Hz}$ and vector reconstruction, an unprecedented spatio-temporal resolution and functionality at room temperature.

cond-mat.mes-hall