SearcharxivSearch

arXiv subjects

Grant Teply

Publications and source records attributed to Grant Teply.

At least 19 recordsLinked to original sources

BICEP/Keck XXI: Constraints on Early-Universe Parity Violation from Multipole-Dependent Birefringence

We present the first constraints on multipole-dependent cosmic birefringence using CMB polarization data from the BK18 dataset, which combines observations from BICEP2, Keck Array, and BICEP3 at frequencies of 95, 150, and 220 GHz. Photon coupling to an axion-like field leads to the rotation of CMB polarization, inducing non-zero EB cross-correlations. We show that a multipole-dependent rotation beta(l) imprints a distinct signature in the polarization spectra that can be constrained. Specifically, we consider an Early Dark Energy (EDE) scenario in which a pseudoscalar field couples to photons through a Chern-Simons interaction, generating a polarization rotation with multipole dependence. We introduce a phenomenological beta(l) as a step function, obtaining constraints on the step function size consistent with zero, with uncertainties less than 0.15 degrees (68% CL). In addition, using multi-frequency EE, BB, and EB cross-spectra, along with robust BICEP/Keck foreground treatment and likelihood framework, we derive constraints on the axion-photon coupling amplitude g for several choices of EDE parameters. For the baseline best-fit value f_{EDE} = 0.087 from the Planck 2018 analysis, we obtain g = 0.11 +/- 0.37 (68% CL), consistent with previous limits.

astro-ph.CO

The Simons Observatory: Design, integration, and testing of the small aperture telescopes

The Simons Observatory (SO) is a cosmic microwave background (CMB) survey experiment that includes small-aperture telescopes (SATs) observing from an altitude of 5,200 m in the Atacama Desert in Chile. The SO SATs will cover six spectral bands between 27 and 280 GHz to search for primordial B-modes to a sensitivity of $σ(r)=0.002$, with quantified systematic errors well below this value. Each SAT is a self-contained cryogenic telescope with a 35$^\circ$ field of view, 42 cm diameter optical aperture, 40 K half-wave plate, 1 K refractive optics, and $<0.1$ K focal plane that holds $>12,000$ TES detectors. We describe the nominal design of the SATs and present details about the integration and testing for one operating at 93 and 145 GHz.

astro-ph.IM

The Simons Observatory: Beam characterization for the Small Aperture Telescopes

We use time-domain simulations of Jupiter observations to test and develop a beam reconstruction pipeline for the Simons Observatory Small Aperture Telescopes. The method relies on a map maker that estimates and subtracts correlated atmospheric noise and a beam fitting code designed to compensate for the bias caused by the map maker. We test our reconstruction performance for four different frequency bands against various algorithmic parameters, atmospheric conditions and input beams. We additionally show the reconstruction quality as function of the number of available observations and investigate how different calibration strategies affect the beam uncertainty. For all of the cases considered, we find good agreement between the fitted results and the input beam model within a ~1.5% error for a multipole range l = 30 - 700 and an ~0.5% error for a multipole range l = 50 - 200. We conclude by using a harmonic-domain component separation algorithm to verify that the beam reconstruction errors and biases observed in our analysis do not significantly bias the Simons Observatory r-measurement.

astro-ph.IM

The Simons Observatory: Constraining inflationary gravitational waves with multi-tracer B-mode delensing

We introduce and validate a delensing framework for the Simons Observatory (SO), which will be used to improve constraints on inflationary gravitational waves (IGWs) by reducing the lensing noise in measurements of the $B$-modes in CMB polarization. SO will initially observe CMB by using three small aperture telescopes and one large-aperture telescope. While polarization maps from small-aperture telescopes will be used to constrain IGWs, the internal CMB lensing maps used to delens will be reconstructed from data from the large-aperture telescope. Since lensing maps obtained from the SO data will be noise-dominated on sub-degree scales, the SO lensing framework constructs a template for lensing-induced $B$-modes by combining internal CMB lensing maps with maps of the cosmic infrared background from Planck as well as galaxy density maps from the LSST survey. We construct a likelihood for constraining the tensor-to-scalar ratio $r$ that contains auto- and cross-spectra between observed $B$-modes and the lensing $B$-mode template. We test our delensing analysis pipeline on map-based simulations containing survey non-idealities, but that, for this initial exploration, does not include contamination from Galactic and extragalactic foregrounds. We find that the SO survey masking and inhomogeneous and atmospheric noise have very little impact on the delensing performance, and the $r$ constraint becomes $σ(r)\approx 0.0015$ which is close to that obtained from the idealized forecasts in the absence of the Galactic foreground and is nearly a factor of two tighter than without delensing. We also find that uncertainties in the external large-scale structure tracers used in our multi-tracer delensing pipeline lead to bias much smaller than the $1\,σ$ statistical uncertainties.

astro-ph.CO

The Simons Observatory: Design and Measured Performance of a Carbon Fiber Strut for a Cryogenic Truss

We present the design and measured performance of a new carbon fiber strut design that is used in a cryogenically cooled truss for the Simons Observatory Small Aperture Telescope (SAT). The truss consists of two aluminum 6061 rings separated by 24 struts. Each strut consists of a central carbon fiber tube fitted with two aluminum end caps. We tested the performance of the strut and truss by (i) cryogenically cycling and destructively pull-testing strut samples, (ii) non-destructively pull-testing the final truss, and (iii) measuring the thermal conductivity of the carbon fiber tubes. We found that the strut strength is limited by the mounting fasteners and the strut end caps, not the epoxy adhesive or the carbon fiber tube. This result is consistent with our numerical predictions. Our thermal measurements suggest that the conductive heat load through the struts (from 4 K to 1 K) will be less than 1 mW. This strut design may be a promising candidate for use in other cryogenic support structures.

astro-ph.IM

BoloCalc: a sensitivity calculator for the design of Simons Observatory

The Simons Observatory (SO) is an upcoming experiment that will study temperature and polarization fluctuations in the cosmic microwave background (CMB) from the Atacama Desert in Chile. SO will field both a large aperture telescope (LAT) and an array of small aperture telescopes (SATs) that will observe in six bands with center frequencies spanning from 27 to 270~GHz. Key considerations during the SO design phase are vast, including the number of cameras per telescope, focal plane magnification and pixel density, in-band optical power and camera throughput, detector parameter tolerances, and scan strategy optimization. To inform the SO design in a rapid, organized, and traceable manner, we have created a Python-based sensitivity calculator with several state-of-the-art features, including detector-to-detector optical white-noise correlations, a handling of simulated and measured bandpasses, and propagation of low-level parameter uncertainties to uncertainty in on-sky noise performance. We discuss the mathematics of the sensitivity calculation, the calculator's object-oriented structure and key features, how it has informed the design of SO, and how it can enhance instrument design in the broader CMB community, particularly for CMB-S4.

astro-ph.IM

Simons Observatory Microwave SQUID Multiplexing Readout -- Cryogenic RF Amplifier and Coaxial Chain Design

The Simons Observatory (SO) is an upcoming polarization-sensitive Cosmic Microwave Background (CMB) experiment on the Cerro Toco Plateau (Chile) with large overlap with other optical and infrared surveys (e.g., DESI, LSST, HSC). To enable the readout of \bigO(10,000) detectors in each of the four telescopes of SO, we will employ the microwave SQUID multiplexing technology. With a targeted multiplexing factor of \bigO{(1,000)}, microwave SQUID multiplexing has never been deployed on the scale needed for SO. Here we present the design of the cryogenic coaxial cable and RF component chain that connects room temperature readout electronics to superconducting resonators that are coupled to Transition Edge Sensor bolometers operating at sub-Kelvin temperatures. We describe design considerations including cryogenic RF component selection, system linearity, noise, and thermal power dissipation.

astro-ph.IM

Small Aperture Telescopes for the Simons Observatory

The Simons Observatory (SO) is an upcoming cosmic microwave background (CMB) experiment located on Cerro Toco, Chile, that will map the microwave sky in temperature and polarization in six frequency bands spanning 27 to 285 GHz. SO will consist of one 6-meter Large Aperture Telescope (LAT) fielding $\sim$30,000 detectors and an array of three 0.42-meter Small Aperture Telescopes (SATs) fielding an additional 30,000 detectors. This synergy will allow for the extremely sensitive characterization of the CMB over angular scales ranging from an arcmin to tens of degrees, enabling a wide range of scientific output. Here we focus on the SATs targeting degree angular scales with successive dichroic instruments observing at Mid-Frequency (MF: 93/145 GHz), Ultra-High-Frequency (UHF: 225/285 GHz), and Low-Frequency (LF: 27/39 GHz). The three SATs will be able to map $\sim$10% of the sky to a noise level of 2 $μ$K-arcmin when combining 93 and 145 GHz. The multiple frequency bands will allow the CMB to be separated from galactic foregrounds (primarily synchrotron and dust), with the primary science goal of characterizing the primordial tensor-to-scalar ratio, $r$, at a target level of $σ\left(r\right) \approx 0.003$.

astro-ph.IM

Standard-Model Extension Constraints on Lorentz and CPT Violation From Optical Polarimetry of Active Galactic Nuclei

Vacuum birefringence from Lorentz and CPT violation in the Standard-Model Extension can be constrained using ground-based optical polarimetry of extragalactic sources. We describe results from a pilot program with an automated system that can perform simultaneous optical polarimetry in multiple passbands on different telescopes with an effective 0.45 m aperture. Despite the limited collecting area, our polarization measurements of AGN using a wider effective optical passband than previous studies yielded individual line-of-sight constraints for Standard-Model Extension mass dimension $d = 5$ operators within a factor of about one to ten of comparable broadband polarimetric bounds obtained using data from a 3.6 m telescope with roughly 64 times the collecting area. Constraining more general anisotropic Standard-Model Extension coefficients at higher $d$ would require more AGN along different lines of sight. This motivates a future dedicated ground-based, multi-band, optical polarimetry AGN survey with $\gtrsim 1$ m-class telescopes, to obtain state-of-the-art anisotropic Standard-Model Extension $d = 4, 5, 6$ constraints, while also using complementary archival polarimetry. This could happen more quickly and cost-effectively than via spectropolarimetry and long before more competitive constraints from space- or balloon-based x-ray/$γ$-ray polarization measurements.

astro-ph.HE

Removal of Galactic foregrounds for the Simons Observatory primordial gravitational wave search

Upcoming observations from the Simons Observatory have been projected to constrain the tensor-to-scalar ratio, $r$, at the level of $σ(r)=$0.003. Here we describe one of the forecasting algorithms for the Simons Observatory in more detail, based on cleaning CMB polarization maps using a parametric model. We present a new code to perform this end-to-end forecast, and explore the assumptions in greater detail. If spatial uniformity of the spectral energy distribution of synchrotron radiation and thermal dust emission is assumed over the region planned for observations, covering almost a fifth of the sky, a bias of order 1--3$σ$ in $r$ is projected for foreground models consistent with current data. We find that by masking the most contaminated regions of sky, or by adopting more parameters to describe the spatial variation in spectral index for synchrotron and dust, such a bias can be mitigated for the foreground models we consider. We also explore strategies for testing whether the cleaned CMB polarization maps contain residual foreground contamination, including cross-correlating with maps tracing the foregrounds. This method also has applications for other CMB polarization experiments.

astro-ph.CO

Constraints on Lorentz Invariance and CPT Violation using Optical Photometry and Polarimetry of Active Galaxies BL Lacertae and S5 B0716+714

Various quantum gravity approaches that extend beyond the standard model predict Lorentz Invariance and Charge-Parity-Time Violation at energies approaching the Planck scale. These models frequently predict a wavelength dependent speed of light, which would result in time delays between promptly emitted photons at different energies, as well as a wavelength-dependent rotation of the plane of linear polarization for photons resulting from vacuum birefringence. Here, we describe a pilot program with an automated system of small telescopes that can simultaneously conduct high cadence optical photometry and polarimetry of Active Galactic Nuclei (AGN) in multiple passbands. We use these observations as a proof-of-principle to demonstrate how such data can be used to test various Lorentz Violation models, including special cases of the Standard Model Extension (SME). In our initial campaign with this system, the Array Photo Polarimeter, we observed two AGN sources, including BL Lacertae at redshift z = 0.069, and S5 B0716+714 at z = 0.31. We demonstrate that optical polarimetry with a broadband Luminance filter combined with simultaneous $I_c$-band observations yields SME parameter constraints that are up to ~10 and ~30 times more sensitive than with a standard $I_c$-band filter, for SME models with mass dimension d = 5 and d = 6, respectively. Using only a small system of telescopes with an effective 0.45-m aperture, we further demonstrate d = 5 constraints for individual lines of sight that are within a factor of ~1-10 in sensitivity to comparable constraints from optical polarimetry with a 3.6-m telescope. Such an approach could significantly improve existing SME constraints via a polarimetric all-sky survey of AGN with multiple 1-meter class telescopes.

astro-ph.HE

Studies of Systematic Uncertainties for Simons Observatory: Detector Array Effects

In this proceeding, we present studies of instrumental systematic effects for the Simons Obsevatory (SO) that are associated with the detector system and its interaction with the full SO experimental systems. SO will measure the Cosmic Microwave Background (CMB) temperature and polarization anisotropies over a wide range of angular scales in six bands with bandcenters spanning from 27 GHz to 270 GHz. We explore effects including intensity-to-polarization leakage due to coupling optics, bolometer nonlinearity, uncalibrated gain variations of bolometers, and readout crosstalk. We model the level of signal contamination, discuss proposed mitigation schemes, and present instrument requirements to inform the design of SO and future CMB projects.

astro-ph.IM

Cooldown Strategies and Transient Thermal Simulations for the Simons Observatory

The Simons Observatory (SO) will provide precision polarimetry of the cosmic microwave background (CMB) using a series of telescopes which will cover angular scales from arc-minutes to tens of degrees, contain over 60,000 detectors, and observe in frequency bands between 27 GHz and 270 GHz. SO will consist of a six-meter-aperture telescope initially coupled to ~35,000 detectors along with an array of 0.5m aperture refractive cameras, coupled to an additional 30,000+ detectors. The large aperture telescope receiver (LATR) is coupled to a six-meter crossed Dragone telescope and will be 2.4m in diameter, weigh over 3 tons, and have five cryogenic stages (80 K, 40 K, 4 K, 1 K and 100 mK). The LATR is coupled to the telescope via 13 independent optics tubes containing cryogenic optical elements and detectors. The cryostat will be cooled by by two Cryomech PT90 (80 K) and three Cryomech PT420 (40 K and 4 K) pulse tube cryocoolers, with cooling of the 1 K and 100 mK stages by a commercial dilution refrigerator system. The second component, the small aperture telescope (SAT), is a single optics tube refractive cameras of 42cm diameter. Cooling of the SAT stages will be provided by two Cryomech PT420, one of which is dedicated to the dilution refrigeration system which will cool the focal plane to 100 mK. SO will deploy a total of three SATs. In order to estimate the cool down time of the camera systems given their size and complexity, a finite difference code based on an implicit solver has been written to simulate the transient thermal behavior of both cryostats. The result from the simulations presented here predict a 35 day cool down for the LATR. The simulations suggest additional heat switches between stages would be effective in distribution cool down power and reducing the time it takes for the LATR to cool. The SAT is predicted to cool down in one week, which meets the SO design goals.

astro-ph.IM

Studies of Systematic Uncertainties for Simons Observatory: Polarization Modulator Related Effects

The Simons Observatory (SO) will observe the temperature and polarization anisotropies of the cosmic microwave background (CMB) over a wide range of frequencies (27 to 270 GHz) and angular scales by using both small (0.5 m) and large (6 m) aperture telescopes. The SO small aperture telescopes will target degree angular scales where the primordial B-mode polarization signal is expected to peak. The incoming polarization signal of the small aperture telescopes will be modulated by a cryogenic, continuously-rotating half-wave plate (CRHWP) to mitigate systematic effects arising from slowly varying noise and detector pair-differencing. In this paper, we present an assessment of some systematic effects arising from using a CRHWP in the SO small aperture systems. We focus on systematic effects associated with structural properties of the HWP and effects arising when operating a HWP, including the amplitude of the HWP synchronous signal (HWPSS), and I -> P (intensity to polarization) leakage that arises from detector non-linearity in the presence of a large HWPSS. We demonstrate our ability to simulate the impact of the aforementioned systematic effects in the time domain. This important step will inform mitigation strategies and design decisions to ensure that SO will meet its science goals.

astro-ph.IM

Designs for next generation CMB survey strategies from Chile

New telescopes are being built to measure the Cosmic Microwave Background (CMB) with unprecedented sensitivity, including Simons Observatory (SO), CCAT-prime, the BICEP Array, SPT-3G, and CMB Stage-4. We present observing strategies for telescopes located in Chile that are informed by the tools used to develop recent Atacama Cosmology Telescope (ACT) and Polarbear surveys. As with ACT and Polarbear, these strategies are composed of scans that sweep in azimuth at constant elevation. We explore observing strategies for both small (0.42 m) aperture telescopes (SAT) and a large (6 m) aperture telescope (LAT). We study strategies focused on small sky areas to search for inflationary gravitational waves as well as strategies spanning roughly half the low-foreground sky to constrain the effective number of relativistic species and measure the sum of neutrino masses via the gravitational lensing signal due to large scale structure. We present these strategies specifically considering the telescope hardware and science goals of the SO, located at 23 degrees South latitude, 67.8 degrees West longitude. Observations close to the Sun and the Moon can introduce additional systematics by applying additional power to the instrument through telescope sidelobes. Significant side lobe contamination in the data can occur even at tens of degrees or more from bright sources. Therefore, we present several strategies that implement Sun and Moon avoidance constraints into the telescope scheduling. Strategies for resolving conflicts between simultaneously visible fields are discussed. We focus on maximizing telescope time spent on science observations. It will also be necessary to schedule calibration measurements, however that is beyond the scope of this work. The outputs of this study are algorithms that can generate specific schedule commands for the Simons Observatory instruments.

astro-ph.IM

The Simons Observatory: Instrument Overview

The Simons Observatory (SO) will make precise temperature and polarization measurements of the cosmic microwave background (CMB) using a set of telescopes which will cover angular scales between 1 arcminute and tens of degrees, contain over 60,000 detectors, and observe at frequencies between 27 and 270 GHz. SO will consist of a 6 m aperture telescope coupled to over 30,000 transition-edge sensor bolometers along with three 42 cm aperture refractive telescopes, coupled to an additional 30,000+ detectors, all of which will be located in the Atacama Desert at an altitude of 5190 m. The powerful combination of large and small apertures in a CMB observatory will allow us to sample a wide range of angular scales over a common survey area. SO will measure fundamental cosmological parameters of our universe, constrain primordial fluctuations, find high redshift clusters via the Sunyaev-Zel`dovich effect, constrain properties of neutrinos, and trace the density and velocity of the matter in the universe over cosmic time. The complex set of technical and science requirements for this experiment has led to innovative instrumentation solutions which we will discuss. The large aperture telescope will couple to a cryogenic receiver that is 2.4 m in diameter and nearly 3 m long, creating a number of technical challenges. Concurrently, we are designing the array of cryogenic receivers housing the 42 cm aperture telescopes. We will discuss the sensor technology SO will use and we will give an overview of the drivers for and designs of the SO telescopes and receivers, with their cold optical components and detector arrays.

astro-ph.IM

Design and characterization of the POLARBEAR-2b and POLARBEAR-2c cosmic microwave background cryogenic receivers

The POLARBEAR-2/Simons Array Cosmic Microwave Background (CMB) polarization experiment is an upgrade and expansion of the existing POLARBEAR-1 (PB-1) experiment, located in the Atacama desert in Chile. Along with the CMB temperature and $E$-mode polarization anisotropies, PB-1 and the Simons Array study the CMB $B$-mode polarization anisotropies produced at large angular scales by inflationary gravitational waves, and at small angular scales by gravitational lensing. These measurements provide constraints on various cosmological and particle physics parameters, such as the tensor-to-scalar ratio $r$, and the sum of the neutrino masses. The Simons Array consists of three 3.5 m diameter telescopes with upgraded POLARBEAR-2 (PB-2) cryogenic receivers, named PB-2a, -2b, and -2c. PB-2a and -2b will observe the CMB over multiple bands centered at 95 GHz and 150 GHz, while PB-2c will observe at 220 GHz and 270 GHz, which will enable enhanced foreground separation and de-lensing. Each Simons Array receiver consists of two cryostats which share the same vacuum space: an optics tube containing the cold reimaging lenses and Lyot stop, infrared-blocking filters, and cryogenic half-wave plate; and a backend which contains the focal plane detector array, cold readout components, and millikelvin refrigerator. Each PB-2 focal plane array is comprised of 7,588 dual-polarization, multi-chroic, lenslet- and antenna-coupled, Transition Edge Sensor (TES) bolometers which are cooled to 250 mK and read out using Superconducting Quantum Interference Devices (SQUIDs) through a digital frequency division multiplexing scheme with a multiplexing factor of 40. In this work we describe progress towards commissioning the PB-2b and -2c receivers including cryogenic design, characterization, and performance of both the PB-2b and -2c backend cryostats.

astro-ph.IM

Performance of a continuously rotating half-wave plate on the POLARBEAR telescope

A continuously rotating half-wave plate (CRHWP) is a promising tool to improve the sensitivity to large angular scales in cosmic microwave background (CMB) polarization measurements. With a CRHWP, single detectors can measure three of the Stokes parameters, $I$, $Q$ and $U$, thereby avoiding the set of systematic errors that can be introduced by mismatches in the properties of orthogonal detector pairs. We focus on the implementation of CRHWPs in large aperture telescopes (i.e. the primary mirror is larger than the current maximum half-wave plate diameter of $\sim$0.5 m), where the CRHWP can be placed between the primary mirror and focal plane. In this configuration, one needs to address the intensity to polarization ($I{\rightarrow}P$) leakage of the optics, which becomes a source of 1/f noise and also causes differential gain systematics that arise from CMB temperature fluctuations. In this paper, we present the performance of a CRHWP installed in the POLARBEAR experiment, which employs a Gregorian telescope with a 2.5 m primary illumination pattern. The CRHWP is placed near the prime focus between the primary and secondary mirrors. We find that the $I{\rightarrow}P$ leakage is larger than the expectation from the physical properties of our primary mirror, resulting in a 1/f knee of 100 mHz. The excess leakage could be due to imperfections in the detector system, i.e. detector non-linearity in the responsivity and time-constant. We demonstrate, however, that by subtracting the leakage correlated with the intensity signal, the 1/f noise knee frequency is reduced to 32 mHz ($\ell \sim$39 for our scan strategy), which is very promising to probe the primordial B-mode signal. We also discuss methods for further noise subtraction in future projects where the precise temperature control of instrumental components and the leakage reduction will play a key role.

astro-ph.IM