Searcharxiv⌕ Search

arXiv subjects

Gregory N. Goltsman

Publications and source records attributed to Gregory N. Goltsman.

7 recordsLinked to original sources

Universal Broadband Linear Optical Transformations by an Interlaced Structured Integrated Photonic Processor

Reconfigurable photonic integrated circuits enable applications in a wide range of fields. They represent a powerful platform for signal processing due to the ability to perform parallel computations. In this work, we demonstrate a photonic processor based on a six-channel universal chip fabricated by femtosecond laser writing with an interlaced architecture comprising multiport beam splitters. We exploit and enhance a previously demonstrated calibration procedure for a single building block, and extend it to a complete six-channel interferometer, reconstructing the corresponding interferometer models over a broad spectral range. We validate them by measuring a set of 100 Haar-random unitary matrices, achieving mean amplitude fidelities of 95.9 %, 98.0 %, and 96.0 % for radiation wavelengths 910, 945, and 980 nm, respectively, without on-device optimization. Furthermore, we experimentally realize spectral demultiplexing and multiplexing at these wavelengths, yielding routing fidelities ranging from 90.1 % to 96.5 % and total crosstalk values ranging from -9.6 to -14.4 dB, confirming the applicability of the fabricated photonic processor to practical wavelength-routing tasks.

physics.optics↗

Effective programming of a photonic processor with complex interferometric structure

Reconfigurable photonics have rapidly become an invaluable tool for information processing. Light-based computing accelerators are promising for boosting neural network learning and inference and optical interconnects are foreseen as a solution to the information transfer bottleneck in high-performance computing. In this study, we demonstrate the successful programming of a transformation implemented using a reconfigurable photonic circuit with a non-conventional architecture. The core of most photonic processors is an MZI-based architecture that establishes an analytical connection between the controllable parameters and circuit transformation. However, several architectures that are substantially more difficult to program have improved robustness to fabrication defects. We use two algorithms that rely on different initial datasets to reconstruct the circuit model of a complex interferometer, and then program the required unitary transformation. Both methods performed accurate circuit programming with an average fidelity greater than 99% and 97%, respectively. Our results provide a strong foundation for the introduction of non-conventional interferometric architectures for photonic information processing.

physics.optics↗

Electron energy relaxation in disordered superconducting NbN films

We report on the inelastic-scattering rate of electrons on phonons and relaxation of electron energy studied by means of magnetoconductance, and photoresponse, respectively, in a series of strongly disordered superconducting NbN films. The studied films with thicknesses in the range from 3 to 33 nm are characterized by different Ioffe-Regel parameters but an almost constant product q_Tl(q_T is the wave vector of thermal phonons and l is the elastic mean free path of electrons). In the temperature range 14-30 K, the electron-phonon scattering rates obey temperature dependencies close to the power law 1/τ_{e-ph} \sim T^n with the exponents n = 3.2-3.8. We found that in this temperature range τ_{e-ph} and n of studied films vary weakly with the thickness and square resistance. At 10 K electron-phonon scattering times are in the range 11.9-17.5 ps. The data extracted from magnetoconductance measurements were used to describe the experimental photoresponse with the two-temperature model. For thick films, the photoresponse is reasonably well described without fitting parameters, however, for thinner films, the fit requires a smaller heat capacity of phonons. We attribute this finding to the reduced density of phonon states in thin films at low temperatures. We also show that the estimated Debye temperature in the studied NbN films is noticeably smaller than in bulk material.

cond-mat.supr-con↗

Potential of a Superconducting Photon Counter for Heterodyne Detection at Telecommunication Wavelength

Here, we report on successful operation of a NbN thin film superconducting nanowire single-photon detector (SNSPD) in a coherent mode (as a mixer) at the telecommunication wavelength of 1550 nm. Providing the Local Oscillator power of the order of a few picowatts, we were practically able to reach the quantum noise limited sensitivity. The intermediate frequency gain bandwidth was limited by the spectral band of single-photon response pulse of the detector, which is proportional to the detector size. We observed gain bandwidth of 65 MHz and 140 MHz for 7x7 um^2 and 3x3 um^2 devices respectively. Tiny amount of the required Local Oscillator power and wide gain and noise bandwidths along with the needless of any Low Noise Amplification opens possibility for a photon counting heterodyne-born megapixel array development.

physics.ins-det↗

Travelling-wave single-photon detectors integrated with diamond photonic circuits - operation at visible and telecom wavelengths with a timing jitter down to 23 ps

We report on the design, fabrication and measurement of travelling-wave superconducting nanowire single-photon detectors (SNSPDs) integrated with polycrystalline diamond photonic circuits. We analyze their performance both in the near-infrared wavelength regime around 1600 nm and at 765 nm. Near-IR detection is important for compatibility with the telecommunication infrastructure, while operation in the visible wavelength range is relevant for compatibility with the emission line of silicon vacancy centers in diamond which can be used as efficient single-photon sources. Our detectors feature high critical currents (up to 31 μA) and high performance in terms of efficiency (up to 74% at 765 nm), noise-equivalent power (down to 4.4*10^-19 W/(Hz^1/2) at 765 nm) and timing jitter (down to 23 ps).

physics.optics↗

Ultra-Broadband Coherence-Domain Imaging Using Parametric Downconversion and Superconducting Single-Photon Detectors at 1064 nm

Coherence-domain imaging systems can be operated in a single-photon counting mode, offering low detector noise; this in turn leads to increased sensitivity for weak light sources and weakly reflecting samples. We have demonstrated that excellent axial resolution can be obtained in a photon-counting coherence domain imaging (CDI) system that uses light generated via spontaneous parametric down-conversion (SPDC) in a chirped periodically poled stoichiometric lithium tantalate (chirped-PPSLT) structure, in conjunction with a niobium nitride superconducting single-photon detector (SSPD). The bandwidth of the light generated via SPDC, as well as the bandwidth over which the SSPD is sensitive, can extend over a wavelength region that stretches from 700 to 1500 nm. This ultra-broad wavelength band offers a near-ideal combination of deep penetration and ultra-high axial resolution for the imaging of biological tissue. The generation of SPDC light of adjustable bandwidth in the vicinity of 1064 nm, via the use of chirped-PPSLT structures, had not been previously achieved. To demonstrate the usefulness of this technique, we have constructed images for a hierarchy of samples of increasing complexity: a mirror, a nitrocellulose membrane, and a biological sample comprising onion-skin cells.

quant-ph↗

Photon-counting optical coherence-domain reflectometry using superconducting single-photon detectors

We consider the use of single-photon counting detectors in coherence-domain imaging. Detectors operated in this mode exhibit reduced noise, which leads to increased sensitivity for weak light sources and weakly reflecting samples. In particular, we experimentally demonstrate the possibility of using superconducting single-photon detectors (SSPDs) for optical coherence-domain reflectometry (OCDR). These detectors are sensitive over the full spectral range that is useful for carrying out such imaging in biological samples. With counting rates as high as 100 MHz, SSPDs also offer a high rate of data acquisition if the light flux is sufficient.

quant-ph↗