SearcharxivSearch

arXiv subjects

Gregory Nordahl

Publications and source records attributed to Gregory Nordahl.

2 recordsLinked to original sources

Event-sparse stack denoising for 4D-STEM applications

We introduce a denoising method for four-dimensional scanning transmission electron microscopy (4D-STEM) that relies on processing local, scan position-independent electron event-sparse data stacks, called event-sparse stack denoising. This method adds an extra time dimension during data collection by recording multiple electron event-sparse diffraction patterns. The resulting datasets are effectively five-dimensional, referred to as locally time-resolved STEM (LTR-STEM). Diffraction data stacks at each scan position are processed using one of two sparsity denoising pipelines: 1) the density-based spatial clustering of applications with noise (DBSCAN) algorithm followed by multi-step persistence thresholding, or 2) sparse principal component analysis (sparse PCA), followed by single-step thresholding. Both methods perform well for diffraction data denoising, as shown by simulated peak signal-to-noise ratio (PSNR) curves, denoised experimental data for virtual imaging, and application-specific denoising for defect detection. PSNR analysis indicates that sparsity-denoised 4D-STEM data reaches the same PSNR as raw data at approximately 16% of the exposure time, demonstrating comparable image quality with a lower dose. In defect detection, a 4.1x increase in sensitivity to relative radial disk shift is observed in the denoised data. Moreover, the LTR-STEM technique may be used to inspect material degradation by tracking changes in diffraction disk intensity, allowing for critical dose estimation and exposure-selective imaging.

physics.med-ph

Correcting for probe wandering by precession path segmentation

Precession electron diffraction has in the past few decades become a powerful technique for structure solving, strain analysis, and orientation mapping, to name a few. One of the benefits of precessing the electron beam, is increased reciprocal space resolution, albeit at a loss of spatial resolution due to an effect referred to as 'probe wandering'. Here, a new methodology of precession path segmentation is presented to counteract this effect and increase the resolution in reconstructed virtual images from scanning precession electron diffraction data. By utilizing fast pixelated electron detector technology, multiple frames are recorded for each azimuthal rotation of the beam, allowing for the probe wandering to be corrected in post-acquisition processing. Not only is there an apparent increase in the resolution of the reconstructed images, but probe wandering due to instrument misalignment is reduced, potentially easing an already difficult alignment procedure.

physics.ins-det