SearcharxivSearch

arXiv subjects

Guang-Jun Wang

Publications and source records attributed to Guang-Jun Wang.

10 recordsLinked to original sources

Mitigating Source and Detection Noises in Auto-correlative Weak-Value Amplification

Weak-value amplification (WVA) is a post-selection-based technique that amplifies weak physical signals by preparing nearly orthogonal pre- and post-selected quantum states. It is intrinsically limited by various kinds of technical noise, which distorts amplified weak values, especially when discarding photons in post-selection. While prior work established the efficacy of auto-correlative weak-value amplification (AWVA) under Gaussian noise, practical implementations face challenges from band-limited laser-source noise and detection noise. Here, we demonstrate that the AWVA protocol robustly suppresses both laser-power fluctuations and detection noise. Numerical experiments in Simulink further reveal AWVA dual advantage. Under high-power conditions, the noise-reduction superiority of AWVA over WVA becomes increasingly pronounced as input laser power increases. In detection-limited regimes, AWVA achieves an order-of-magnitude lower uncertainty, closely approaching the Cramer-Rao bound. This work demonstrates that AWVA improves precision in both high-power laser-noise-dominated and photon-starved regimes, thereby bridging these operating extremes and advancing precision in applications from gravitational-wave detection to hybrid quantum systems.

quant-ph

Real-time analog circuit for auto-correlative weak-value amplification in the time domain

The auto-correlative weak-value amplification (AWVA) technique demonstrates distinct advantages over standard weak-value amplification (SWVA) for quantum parameter estimation. To achieve enhanced precision in real-time parameter estimation, the AWVA requires additional resources compared to SWVA, namely real-time multiplication and integrator modules. We implemented a real-time analog circuit for AWVA using an AD835 multiplier and an NE5532 operational amplifier for the integrator. The circuit was tested using Gaussian pointers in the AWVA scheme, exhibiting sufficient sensitivity for Gaussian pointers with frequencies 200 Hz < f < 20kHz. Compared to SWVA, AWVA achieves higher accuracy and superior robustness against noise at signal-to-noise ratios (SNRs) of -12 dB < SNR < -4 dB. Beyond quantum metrology, the circuit is applicable to diverse detection schemes for correlated signals.

quant-ph

A potential third-generation gravitational-wave detector based on autocorrelative weak-value amplification

Reducing noises and enhancing signal-to-noise ratios (SNRs) have become critical for designing third-generation gravitational-wave (GW) detectors with a GW strain of less than $10^{-23}$/$\rm \sqrt{Hz}$. In this paper, we propose a potential third-generation GW detector based on autocorrelative weak-value amplification (AWVA) for GW detection with a strain of $h_g =$ $4 \times 10^{-25}$/$\rm \sqrt{Hz}$. In our scheme, a GW event induces a phase difference $Δϕ$ by passing through an 11-bounce delay line, 10-km arm-length, zero-area Sagnac interferometer illuminated with a 1064-nm laser. Subsequently, $Δϕ$ is amplified as the parameter of post-selection by choosing the appropriate pre-selected state and coupling strength in AWVA. In particular, we theoretically investigate the AWVA measurements for GW detection within the frequency band of 200 Hz $\leq$ $f_g$ $\leq$ 800 Hz, considering Gaussian noises with negative-decibel SNRs. The peak response of the AWVA sensitivity $κ(f_g)$ occurs at frequency $f_{g, max}$ = 500 Hz, which falls within the frequency band of interest of the current third-generation GW detectors. Our simulation results indicate that AWVA can demonstrate a measurable sensitivity of $Θ(f_g)$ within the frequency band of interest. Moreover, the robustness of WVA shows promising potential in mitigating the effects of Gaussian noises.

gr-qc

Influence of light quark loops on the Wigner phase with Dyson-Schwinger equations approach

We study the influence of light quark loops on the Wigner phase by solving coupled Dyson-Schwinger equations for quark propagator and gluon propagator. We take the gluon propagator in the Nambu phase from $N_f$ = 2 unquenched lattice QCD and choose various phenomenological models for the quark-gluon vertex. The gluon propagator in Winger phase is assumed to be different from that in the Nambu phase only due to the vacuum polarization of the quark loop. We obtain the Wigner solution of the coupled equations, compared with that from solving only the equation of the quark propagator. We discussed the corrections by the light quark loops and the dependence on various models of the quark-gluon vertex.

hep-ph

The systematic error and the anomaly in the sensitivity and the probability of post-selection raised from the plural weak value

Recently, weak value $\rm A_w$ derived in the pre- and post-selected weak measurement has been shown to be powerful in measuring minute physical effects. In principle, the decrease in the post-selection probability will increase the sensitivity. Besides, the sensitivity which characterizes the pointer position shift is proportional to the real part of $\rm A_w$, and the sensitivity which characterizes the pointer shift in momentum space is proportional to the imaginary part of $\rm A_w$. However, we find that the relationship between the post-selection probability and the sensitivity is true when $\rm A_w$ is a purely real number or a purely imaginary number. The plural $\rm A_w$ will lead to the abnormal behavior where the decrease in the post-selection probability reduce the sensitivity at certain pre- and post-selection. In addition, considering the device imperfections and the environmental instability in the WVA protocol, this anomaly raised from plural $\rm A_w$ will reduce the sensitivity and generate a systematic error of the measurement compared with the original scheme. Finally, three feasible methods are proposed to reduce these negative effects when the weak measurement inevitably changes into measurement with a plural weak value.

quant-ph

The design of a new fiber optic sensor for measuring linear velocity with pico meter/second sensitivity based on Weak-value amplification

We put forward a new fiber optic sensor for measuring linear velocity with picometer/second sensitivity with Weak-value amplification based on generalized Sagnac effect [Phys. Rev. Lett.\textbf{93}, 143901(2004)].The generalized Sagnac effect was first introduced by Yao et al, which included the Sagnac effect of rotation as a special case and suggested a new fiber optic sensor for measuring linear motion with nanoscale sensitivity. By using a different scheme to perform the Sagnac interferometer with the probe in momentum space, we have demonstrated the new weak measure protocol to detect the linear velocity by amplifying the phase shift of the generalized Sagnac effect. Given the maximum incident intensity of the initial spectrum, the detection limit of the intensity of the spectrometer, we can theoretically give the appropriate pre-selection, post-selection, and other optical structures before the experiment. Our numerical results show our scheme with Weak-value amplification is effective and feasible to detect linear velocity with picometer/second sensitivity which is three orders of magnitude smaller than the result $ν$=4.8 $\times$ $10^{-9}$ m/s obtained by generalized Sagnac effect with same fiber length.

quant-ph

A historical review and Bibliometric analysis of research on Weak measurement research over the past decades based on Biblioshiny

Weak measurement has enabled fundamental studies in both experiment and theory of quantum measurement. Numerous researches have indicated that weak measurements have a wide range of application and scientific research value. In our work, we used bibliometric methods to evaluate the global scientific output of research on Weak measurement and explore the current status and trends in this field from 2000 to 2020. The R bibliometric package was used for quantitative and qualitative analyses of publication outputs and author contributions. In total, 636 related articles and reviews were included in the final analysis. The main results were as follows: The number of publications has increased substantially with time. Physical Review A was the most active journal. The country and institution contributing the most to this field were The United States and University Rochester respectively. The analysis of the conceptual structure of keywords indicated that weak measurements were involved a variety of metrology, quantum communication, and nonclassical features of quantum mechanics. Our bibliometric analysis shows that weak measurement research continues to be a hot-spot. The focus has evolved to study quantum information and amplify weak signals.

cs.DL

Improving the precision of weak-value-amplification with two cascaded Michelson interferometers based on Vernier-effect

A modified-weak-value-amplification(MWVA) technique of measuring the mirror's velocity based on the Vernier-effect has been proposed. We have demonstrated with sensitivity-enhanced and the higher signal-to-noise ratio(${\rm SNR}$) by using two cascaded Michelson interferometers. These two interferometers are composed of similar optical structures. One interferometer with a fixed mirror acts as a fixed part of the Vernier-scale, while the other with a moving mirror acts as a sliding part of the Vernier-scale for velocity sensing. The envelope of the cascaded interferometers shifts much more than a single one with a certain enhancement factor, which is related to the free space range difference between these two interferometers. In addition, we calculate the ${\rm SNR}$ based on the Fisher information with both the MWVA technique and the traditional-weak-value-amplification(TMVA) technique. The results show that the ${\rm SNR}$ with our MWVA technique is larger than the the ${\rm SNR}$ with the TWVA technique within the range of our time measurement window. Our numerical analysis proved that our MWVA technique is more efficient than the TWVA technique. And by using the principles of the Vernier-effect, it is applicative and convenient to ulteriorly improving the sensitivity and ${\rm SNR}$ in measuring other quantities with the MWVA technique.

physics.optics

nonlocal quark condensate from Dyson-Schwinger Equation and its contributions to the gluon vacuum polarization based on OPE approach

The operator-product expansion(OPE) could be employed to obtain the lowest-order, nonlocal quark scalar condensate component of gluon vacuum polarization. In particular, nonlocal quark scalar condensate can be calculated by solving Dyson-Schwinger Equation(DSE) of QCD. Then, field-theoretic aspects of the gluon vacuum polarization and nonperturbative gluon propagator will be considered in the Landau gauge of the Lorentz gauge fixing. The gluon propagator we obtained is finite in the infrared domain where the single gluon mass $m_g$ can be determined. Our results of the ratio $m_{g}/Λ_{QCD}$ the range of that from 1.33 to 1.39 agree with previous determinations for this ratio. Besides, the analytic structure of the gluon propagators from the OPE's result is explored. Our numerical analysis of the gluon' Schwinger function finds clear evidence of the positivity violations in the gluon propagator. In addition, a new method for obtaining the chemical potential dependence of the gluon vacuum polarization and the dressed gluon propagator is developed.

hep-ph

Weak-value technique for detecting weak magnetic field based on Faraday magneto-optic effect

We study the amplification of weak magnetic field with Weak-value technique based on Faraday magneto-optic effect. By using a different scheme to perform the Sagnac interferometer with the probe in momentum space, we have demonstrated the new weak measure protocol to detect the small weak magnetic field by amplifying the phase shift of Faraday magneto-optic effect. At the given the maximum incident intensity of the initial spectrum, the detection limit of the intensity of the spectrometer and the accuracy of detecting weak magnetic field, we can theoretically give the appropriate pre-selection, post-selection and others optical structure before experiment. Our numerical results show our scheme with Weak-value technique is effective and feasible to detect weak magnetic field with magnetic field intensity lower than $10^{-10}$ T.

quant-ph