SearcharxivSearch

arXiv subjects

Guillem Pratx

Publications and source records attributed to Guillem Pratx.

4 recordsLinked to original sources

A microscopic computational simulation of [18F]FDG transport and metabolism identifies valid regimes for compartmental analysis

18F-fluorodeoxyglucose ([18F]FDG) positron emission tomography (PET), combined with compartmental modeling, is a powerful non-invasive imaging method for assessing cellular metabolism. However, classical two- and three-tissue compartment models assume homogeneous [18F]FDG distribution within the tissue, which needs justification, and the definition and interpretation of rate constants across these models is not always consistent. To address these issues, we develop a finite difference solver to simulate [18F]FDG transport and metabolism within a 1 mm3 tissue volume, representing the smallest volume resolvable by PET. Our simulations reveal sub-millimeter heterogeneity in [18F]FDG distribution and show that the measured PET signal is dependent not only on cellular metabolic activity but also on interstitial [18F]FDG diffusivity, vascular permeability, and vascular architecture. We further demonstrate that our finite-difference simulation reduces to a three-tissue compartment model when interstitial [18F]FDG concentration is homogeneous. Furthermore, this simplified model itself reduces to the two-tissue compartment model when vascular permeability is sufficiently high. This work quantitatively links vascular permeability, vascular architecture, cellular uptake kinetics, [18F]FDG diffusivity, and acquisition time. It also unifies the two- and three-tissue compartment models and identifies their applicable regimes. These findings deepen our understanding of [18F]FDG transport kinetics and enhance the interpretability of dynamic [18F]FDG-PET imaging.

q-bio.TO

Critical Shortfall in NIH Support for Medical Physics Research

This report summarizes changes in federal research funding to the medical physics community between FY24 and FY25. By linking the AAPM membership database with NIH RePORTER records, we quantified the distribution of NIH funding for projects led by AAPM researchers. Although total NIH funding to AAPM members remained relatively stable across the two years, the composition of that funding shifted substantially. Competing (new and renewal) awards declined 50%, driven largely by an 80% collapse in new R01 grants from the National Cancer Institute (NCI). In contrast, noncompeting continuation awards increased by 10%, following a shift in how NIH funds multi-year projects. These changes occurred in the context of widespread disruptions to NIH review and grantmaking, including delayed study sections and more stringent administrative requirements. Federal funding is essential to sustaining innovation, supporting early-stage investigators, and ensuring that patients receive the best possible care. The trends identified here raise concerns about the long-term vitality and stability of the medical physics research pipeline.

physics.med-ph

Patient-specific mean teacher UNet for enhancing PET image and low-dose PET reconstruction on RefleXion X1 biology-guided radiotherapy system

The RefleXion X1 is the first biology-guided radiotherapy (BgRT) system. Its dual 90-degree PET detector collects fewer pair production events compared to a full-ring diagnostic PET system. In the proposed BgRT workflow, a short scan is acquired before treatment delivery to ensure image quality and consistency. The shorter scan time, a quarter of the simulation scan time, also leads to fewer coincidence events and hence reduced image quality. In this study, we proposed a patient-specific mean teacher UNet (MT-UNet) to enhance PET image quality and low-dose PET reconstruction on RefleXion X1. PET/CT scans of nine cancer patients were acquired using RefleXion X1. Every patient had one simulation scan. Five patients had additional scans acquired during the first and the final treatment fractions. Treatment scans were acquired using the same imaging protocol as the simulation scan. For each scan, we reconstructed a full-dose image and evenly split coincidence events into four sessions to reconstruct four quarter-dose PET images. For each patient, our proposed MT-UNet was trained using quarter-dose and full-dose images of the simulation scan. For the image quality enhancement task, we applied nine trained MT-UNets to full-dose simulation PET images of the nine patients to generate enhanced images, respectively. The enhanced images were compared with the original full-dose images using CNR and SNR. For the low-dose image reconstruction task, we applied five trained MT-UNets to ten quarter-dose treatment images of five patients to predict full-dose images, respectively. The predicted and ground truth full-dose images were compared using SSIM and PSNR. We also trained and evaluated patient-specific UNets for model comparison. Our proposed patient-specific MT-UNet achieved better performance in improving the quality of RefleXion low-dose and full-dose images compared to the patient-specific UNet.

physics.med-ph

A computational model of radiolytic oxygen depletion during FLASH irradiation and its effect on the oxygen enhancement ratio

Recent results from animal irradiation studies have rekindled interest in the potential of ultra-high dose rate irradiation (also known as FLASH) for reducing normal tissue toxicity. However, despite mounting evidence of a "FLASH effect", a mechanism has yet to be elucidated. This article hypothesizes that the radioprotecting effect of FLASH irradiation could be due to the specific sparing of hypoxic stem cell niches, which have been identified in several organs including the bone marrow and the brain. To explore this hypothesis, a new computational model is presented that frames transient radiolytic oxygen depletion (ROD) during FLASH irradiation in terms of its effect on the oxygen enhancement ratio (OER). The model takes into consideration oxygen diffusion through the tissue, its consumption by metabolic cells, and its radiolytic depletion to estimate the relative decrease in radiosensitivity of cells receiving FLASH irradiation. Based on this model, several predictions are made that could be tested in future experiments: (1) the FLASH effect should gradually disappear as the radiation pulse duration is increased from <1s to 10 s; (2) dose should be deposited using the smallest number of radiation pulses to achieve the greatest FLASH effect; (3) a FLASH effect should only be observed in cells that are already hypoxic at the time of irradiation; and (4) changes in capillary oxygen tension (increase or decrease) should diminish the FLASH effect.

physics.med-ph