SearcharxivSearch

arXiv subjects

Guozhu He

Publications and source records attributed to Guozhu He.

3 recordsLinked to original sources

{\alpha}/{\gamma} discrimination method for bulky BaF2 detector used in {\gamma} total absorption facility

The gamma-ray total absorption facility (GTAF) composed of 40 BaF2 detection units is designed to measure the cross section data of neutron radiation capture reaction online, in order to comply with the experimental nuclear data sheet.We have found that one of the most important sources of experimental background is the initial alpha particles emitted by the BaF2 crystal. Developing data analysis algorithms to eliminate the influence of alpha particles in experimental data has become a key aspect. In this work, in order to meet the needs of data acquisition, online measurement and analysis of neutron radiation cross section, the GTAF data acquisition system adopts a full waveform acquisition method, which results in a large number of data recorded, transmitted, and stored during experiment, which also affects the uncertainty of the cross-section data.Based on the signal waveform characteristics of the BaF2 detection unit, in order to solve the aforementioned problems, three methods, namely the ratio of fast component to total component, pulse width, and time decay constant, are used to identify and distinguish alpha particles and gamma rays. The quality factor FOM is utilized as an evaluation value and several experiments are conducted using three radioactive sources (22Na, 137Cs, 60Co) for verification.

physics.ins-det

Measurement of the neutron beam profile of the Back-n white neutron facility at CSNS with a Micromegas detector

The Back-n white neutron beam line, which uses back-streaming white neutrons from the spallation target of the China Spallation Neutron Source, is used for nuclear data measurements. A Micromegas-based neutron detector with two variants was specially developed to measure the beam spot distribution for this beam line. In this article, the design, fabrication, and characterization of the detector are described. The results of the detector performance tests are presented, which include the relative electron transparency, the gain and the gain uniformity, and the neutron beam profile reconstruction capability. The result of the first measurement of the Back-n neutron beam spot distribution is also presented.

physics.ins-det

Measurements of differential and angle-integrated cross sections for the $^{10}$B($n, α$)$^{7}$Li reaction in the neutron energy range from 1.0 eV to 2.5 MeV

Differential and angle-integrated cross sections for the $^{10}$B($n, α$)$^{7}$Li, $^{10}$B($n, α$$_{0}$)$^{7}$Li and $^{10}$B($n, α$$_{1}$)$^{7}$Li$^{*}$ reactions have been measured at CSNS Back-n white neutron source. Two enriched (90%) $^{10}$B samples 5.0 cm in diameter and ~85.0 $μ$g/cm$^{2}$ in thickness each with an aluminum backing were prepared, and back-to-back mounted at the sample holder. The charged particles were detected using the silicon-detector array of the Light-charged Particle Detector Array (LPDA) system. The neutron energy E$_{n}$ was determined by TOF (time-of-flight) method, and the valid $α$ events were extracted from the E$_{n}$-Amplitude two-dimensional spectrum. With 15 silicon detectors, the differential cross sections of $α$-particles were measured from 19.2° to 160.8°. Fitted with the Legendre polynomial series, the ($n, α$) cross sections were obtained through integration. The absolute cross sections were normalized using the standard cross sections of the $^{10}$B($n, α$)$^{7}$Li reaction in the 0.3 - 0.5 MeV neutron energy region. The measurement neutron energy range for the $^{10}$B($n, α$)$^{7}$Li reaction is 1.0 eV $\le$ En < 2.5 MeV (67 energy points), and for the $^{10}$B($n, α$$_{0}$)$^{7}$Li and $^{10}$B($n, α$$_{1}$)$^{7}$Li$^{*}$ reactions is 1.0 eV $\le$ En < 1.0 MeV (59 energy points). The present results have been analyzed by the resonance reaction mechanism and the level structure of the $^{11}$B compound system, and compared with existing measurements and evaluations.

nucl-ex