SearcharxivSearch

arXiv subjects

Gustav Pettersson

Publications and source records attributed to Gustav Pettersson.

3 recordsLinked to original sources

Fundamental Noise Limits of Infrared Detectors in the Presence of Readout Glow

Read noise in infrared sensor arrays remains a major obstacle for ground- and space-based astronomy. It has long been recognized that the upcoming extremely large telescopes cannot meet their full potential unless read noise is significantly improved, and it is also a prohibitive constraint on the Habitable Worlds Observatory, a space telescope with the goal of detection and characterization of nearby Earth-like exoplanets. The main strategy for lowering read noise is averaging through multiple non-destructive reads. However, this typically results in less noise reduction than the 1/$\sqrt{N}$ scaling predicted by theory. In this work, we show the poor averaging behavior can largely be explained by readout glow, photon emission from the sensor electronics that generates photoelectrons in the pixels during readout. Because glow accumulates with reads rather than averaging, this imposes a fundamental noise floor of σ_{\rm min} ~ 1.5 sigma_RN^(1/2)G^(1/4). This limits averaging in HxRG-like sensors to about 2-3 e- of noise, and linear-mode avalanche photodiodes (LmAPDs) to about 0.5 e-. We present laboratory data using both sensor architectures, with the LmAPD following the predicted noise value to within 0.1 e- over two decades of averaging.

astro-ph.IM

On Improving Nuclear Fuel Imaging Using Position Sensitive Detectors

Spent nuclear fuel imaging before disposal is of utmost importance before long term disposal in dedicated storage facilities. Passive Gamma Emission Tomography (PGET) is an approved method by the International Atomic Energy Agency. The present detection system is based on small CZT detectors behind a tungsten-based collimator consisting of a linear array of slits. Small scale CZT crystals limit the detection efficiency of high energetic gamma rays from the fuel rods, mainly the 662 keV emissions from Cs-137. In our study based on full Monte-Carlo simulations as well as on experiments, we explore the capabilities of large pixelated CZT detectors to be used for PGET. We will discuss the theoretical advantages and practical challenges of the larger crystals. We demonstrate that the larger crystals, depending on their orientation, will increase the detection efficiency by a factor of 7 to 13. Due to the pixelated sensor signal readout we also explore the possibility to employ Compton imaging to improve the information on the location of origin of gamma rays. In addition we explore the usefulness of commercial gamma-ray imagers for waste characterisation and decommissioning. In particular we report on the performance of the GeGI imager from PHDS Co and the H420 imager from H3D Inc in measuring nuclear waste drums at Svafo, Sweden.

physics.ins-det

Characterization of the Teledyne COSMOS Camera: A Large Format CMOS Image Sensor for Astronomy

The Teledyne COSMOS-66 is a next-generation CMOS camera designed for astronomical imaging, featuring a large-format sensor ($8120 \times 8120$ pixels, each $10 μm$), high quantum efficiency, high frame rates, and a correlated multi-sampling mode that achieves low read noise. We performed a suite of bench-top and on-sky tests to characterize this sensor and analyze its suitability for use in astronomical instruments. This paper presents measurements of linearity, conversion gain, read noise, dark current, quantum efficiency, image lag, and crosstalk. We found that the sensor exhibits nonlinear response below 5% of saturation. This nonlinearity is plausibly attributable to the trapping of electrons in each pixel. We developed and implemented a pixel-by-pixel nonlinearity correction, enabling accurate photometric measurements across the dynamic range. After implementing this correction, operating in the correlated multi-sampling mode, the sensor achieved an effective read noise of $2.9 e^-$ and dark current of $0.12 e^-/pix/s$ at $-25^\circ C$. The quantum efficiency exceeded 50% from 250 nm to 800 nm, peaking at 89% at 600 nm. We observed significant optical crosstalk between the pixels, likely caused by photoelectron diffusion. To demonstrate the sensor's astronomical performance, we mounted it on the WINTER 1m telescope at Palomar Observatory. These tests confirmed that the linearity calibration enables accurate stellar photometry and validated our measured noise levels. Overall, the COSMOS-66 delivers similar noise performance to large-format CCDs, with higher frame rates and relaxed cooling requirements. If pixel design improvements are made to mitigate the nonlinearity and crosstalk, then the camera may combine the advantages of low-noise CMOS image sensors with the integration simplicity of large-format CCDs, broadening its utility to a host of astronomical science cases.

astro-ph.IM