Searcharxiv⌕ Search

arXiv subjects

H. -W. Ortjohann

Publications and source records attributed to H. -W. Ortjohann.

15 recordsLinked to original sources

An active Transverse Energy Filter based on microstructured Si-PIN diodes with an angular-selective detection efficiency

Si-PIN detectors can be microstructured to achieve angular-selective particle detection capabilities, which we call active Transverse Energy Filter (aTEF). The microstructuring consists of a honeycomb structure of deep hexagonally-shaped holes with active silicon side walls, while the bottom of the holes is made insensitive to ionizing radiation. The motivation for this kind of detector arises from the need to distinguish background electrons from signal electrons in a spectrometer of MAC-E filter type. We have demonstrated the angular-dependent detection efficiency of self-fabricated aTEF prototypes in a test setup using an angular-selective photoelectron source to illuminate the detector from various incidence angles.

physics.ins-det↗

An active transverse energy filter to differentiate low energy particles with large pitch angles in a strong magnetic field

We present the idea and proof of principle measurements for an angular-selective active filter for charged particles. The motivation for the setup arises from the need to distinguish background electrons from signal electrons in a spectrometer of MAC-E filter type. While a large fraction of the background electrons exhibit predominantly small angles relative to the magnetic guiding field (corresponding to a low amount of kinetic energy in the motion component transverse to the field lines, in the following referred to as transverse energy) and pass the filter mostly unhindered, signal electrons from an isotropically emitting source interact with the active filter and are detected. The concept is demonstrated using a microchannel plate (MCP) as an active filter element. When correctly aligned with the magnetic field, electrons with a small transverse energy pass the channels of the MCP without interaction while electrons with large transverse energies hit the channel walls and trigger an avalanche of secondary electrons that is subsequently detected. Due to several drawbacks of MCPs for an actual transverse energy filter, an alternative detection technique using microstructured Si-PIN diodes is proposed.

physics.ins-det↗

Forward Beam Monitor for the KATRIN experiment

The \textit{KArlsruhe TRItium Neutrino} (KATRIN) experiment aims to measure the neutrino mass with a sensitivity of \SI{0.2}{\electronvolt} (\SI{90}{\percent} CL). This will be achieved by a precision measurement of the endpoint region of the $\upbeta$-electron spectrum of tritium decay. The $\upbeta$-electrons are produced in the \textit{Windowless Gaseous Tritium Source} (WGTS) and guided magnetically through the beamline. In order to accurately extract the neutrino mass the source activity is required to be stable and known to a high precision. The WGTS therefore undergoes constant extensive monitoring from several measurement systems. The \textit{Forward Beam Monitor} (FBM) is one such monitoring system. The FBM system comprises a complex mechanical setup capable of inserting a detector board into the KATRIN beamline with a positioning precision of better than \SI{0.3}{\milli\metre}. The electron flux density at that position is on the order of \SI{e6}{\per\second\per\milli\metre\squared}. The detector board contains two silicon detector chips of \pin diode type which can measure the $\upbeta$-electron flux from the source with a precision of \SI{0.1}{\percent} within \SI{60}{\second} with an energy resolution of FWHM $=$ \SI{2}{\kilo\electronvolt}. The unique challenge in developing the FBM arise from its designated operating environment inside the Cryogenic Pumping Section which is a potentially tritium contaminated ultra-high vacuum chamber at cryogenic temperatures in the presence of a \SI{1}{\tesla} strong magnetic field. Each of theses parameters do strongly limit the choice of possible materials which e.g. caused difficulties in detector noise reduction, heat dissipation and lubrication. In order to completely remove the FBM from the beam tube a \SI{2}{\meter} long traveling distance into the beamline is needed demanding a robust as well as highly precise moving mechanism.

physics.ins-det↗

Laser spectroscopy of the $^2S_{1/2} - ^2P_{1/2}$, $^2P_{3/2}$ transitions in stored and cooled relativistic C$^{3+}$ ions

The $^2S_{1/2} - ^2P_{1/2}$ and $^2S_{1/2} - ^2P_{3/2}$ transitions in Li-like carbon ions stored and cooled at a velocity of $β\approx 0.47$ in the Experimental Storage Ring (ESR) at the GSI Helmholtz Centre in Darmstadt have been investigated in a laser spectroscopy experiment. Resonance wavelengths were obtained using a new continuous-wave UV laser system and a novel extreme UV (XUV) detection system to detect forward emitted fluorescence photons. The results obtained for the two transitions are compared to existing experimental and theoretical data. A discrepancy found in an earlier laser spectroscopy measurement at the ESR with results from plasma spectroscopy and interferometry has been resolved and agreement between experiment and theory is confirmed.

physics.atom-ph↗

Suppression of Penning discharges between the KATRIN spectrometers

The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)neutrino mass with a sensitivity of $0.2\textrm{ eV/c}^2$ (90$\%$ C.L.) by precisely measuring the endpoint region of the tritium $β$-decay spectrum. It uses a tandem of electrostatic spectrometers working as MAC-E (magnetic adiabatic collimation combined with an electrostatic) filters. In the space between the pre-spectrometer and the main spectrometer, an unavoidable Penning trap is created when the superconducting magnet between the two spectrometers, biased at their respective nominal potentials, is energized. The electrons accumulated in this trap can lead to discharges, which create additional background electrons and endanger the spectrometer and detector section downstream. To counteract this problem, "electron catchers" were installed in the beamline inside the magnet bore between the two spectrometers. These catchers can be moved across the magnetic-flux tube and intercept on a sub-ms time scale the stored electrons along their magnetron motion paths. In this paper, we report on the design and the successful commissioning of the electron catchers and present results on their efficiency in reducing the experimental background.

physics.ins-det↗

First transmission of electrons and ions through the KATRIN beamline

The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90% confidence level), via a precise measurement of the endpoint spectrum of tritium beta decay. This work documents several KATRIN commissioning milestones: the complete assembly of the experimental beamline, the successful transmission of electrons from three sources through the beamline to the primary detector, and tests of ion transport and retention. In the First Light commissioning campaign of Autumn 2016, photoelectrons were generated at the rear wall and ions were created by a dedicated ion source attached to the rear section; in July 2017, gaseous Kr-83m was injected into the KATRIN source section, and a condensed Kr-83m source was deployed in the transport section. In this paper we describe the technical details of the apparatus and the configuration for each measurement, and give first results on source and system performance. We have successfully achieved transmission from all four sources, established system stability, and characterized many aspects of the apparatus.

physics.ins-det↗

A pulsed, mono-energetic and angular-selective UV photo-electron source for the commissioning of the KATRIN experiment

The KATRIN experiment aims to determine the neutrino mass scale with a sensitivity of 200 meV/c^2 (90% C.L.) by a precision measurement of the shape of the tritium $β$-spectrum in the endpoint region. The energy analysis of the decay electrons is achieved by a MAC-E filter spectrometer. To determine the transmission properties of the KATRIN main spectrometer, a mono-energetic and angular-selective electron source has been developed. In preparation for the second commissioning phase of the main spectrometer, a measurement phase was carried out at the KATRIN monitor spectrometer where the device was operated in a MAC-E filter setup for testing. The results of these measurements are compared with simulations using the particle-tracking software "Kassiopeia", which was developed in the KATRIN collaboration over recent years.

physics.ins-det↗

Commissioning of the vacuum system of the KATRIN Main Spectrometer

The KATRIN experiment will probe the neutrino mass by measuring the beta-electron energy spectrum near the endpoint of tritium beta-decay. An integral energy analysis will be performed by an electro-static spectrometer (Main Spectrometer), an ultra-high vacuum vessel with a length of 23.2 m, a volume of 1240 m^3, and a complex inner electrode system with about 120000 individual parts. The strong magnetic field that guides the beta-electrons is provided by super-conducting solenoids at both ends of the spectrometer. Its influence on turbo-molecular pumps and vacuum gauges had to be considered. A system consisting of 6 turbo-molecular pumps and 3 km of non-evaporable getter strips has been deployed and was tested during the commissioning of the spectrometer. In this paper the configuration, the commissioning with bake-out at 300°C, and the performance of this system are presented in detail. The vacuum system has to maintain a pressure in the 10^{-11} mbar range. It is demonstrated that the performance of the system is already close to these stringent functional requirements for the KATRIN experiment, which will start at the end of 2016.

physics.ins-det↗

An angular-selective electron source for the KATRIN experiment

The KATRIN experiment is going to search for the average mass of the electron antineutrino with a sensitivity of 0.2 eV/c2. It uses a retardation spectrometer of MAC-E filter type to accurately measure the shape of the electron spectrum at the endpoint of tritium beta decay. In order to achieve the planned sensitivity the transmission properties of the spectrometer have to be understood with high precision for all initial conditions. For this purpose an electron source has been developed that emits single electrons at adjustable total energy and adjustable emission angle. The emission is pointlike and can be moved across the full flux tube that is imaged onto the detector. Here, we demonstrate that this novel type of electron source can be used to investigate the transmission properties of a MAC-E filter in detail.

physics.ins-det↗

Detection system for forward emitted photons at the Experimental Storage Ring at GSI

A single photon counting system has been developed for efficient detection of forward emitted fluorescence photons at the Experimental Storage Ring (ESR) at GSI. The system employs a movable parabolic mirror with a central slit that can be positioned around the ion beam and a selected low noise photomultiplier for detection of the collected photons. Compared to the previously used system of mirror segments installed inside the ESR the collection efficiency for forward-emitted photons is improved by more than a factor of 5. No adverse effects on the stored ion beam have been observed during operation besides a small drop in the ion current of about 5% during movement of the mirror into the beam position. The new detection system has been used in the LIBELLE experiment at ESR and enabled for the first time the detection of the ground-state hyperfine M1 transition in lithium-like bismuth (209Bi80+) in a laser-spectroscopy measurement.

physics.atom-ph↗

Next generation KATRIN high precision voltage divider for voltages up to 65kV

The KATRIN (KArlsruhe TRItium Neutrino) experiment aims to determine the mass of the electron antineutrino with a sensitivity of 200meV by precisely measuring the electron spectrum of the tritium beta decay. This will be done by the use of a retarding spectrometer of the MAC-E-Filter type. To achieve the desired sensitivity the stability of the retarding potential of -18.6kV has to be monitored with a precision of 3ppm over at least two months. Since this is not feasible with commercial devices, two ppm-class high voltage dividers were developed, following the concept of the standard divider for DC voltages of up to 100kV of the Physikalisch-Technische Bundesanstalt (PTB). In order to reach such high accuracies different effects have to be considered. The two most important ones are the temperature dependence of resistance and leakage currents, caused by insulators or corona discharges. For the second divider improvements were made concerning the high-precision resistors and the thermal design of the divider. The improved resistors are the result of a cooperation with the manufacturer. The design improvements, the investigation and the selection of the resistors, the built-in ripple probe and the calibrations at PTB will be reported here. The latter demonstrated a stability of about 0.1ppm/month over a period of two years.

physics.ins-det↗

Ellipsometry with polarisation analysis at cryogenic temperatures inside a vacuum chamber

In this paper we describe a new variant of null ellipsometry to determine thicknesses and optical properties of thin films on a substrate at cryogenic temperatures. In the PCSA arrangement of ellipsometry the polarizer and the compensator are placed before the substrate and the analyzer after it. Usually, the polarizer and the analyzer are rotated to find the intensity minimum searched for in null ellipsometry. In our variant we rotate the polarizer and the compensator instead, both being placed in the incoming beam before the substrate. Therefore the polarization analysis of the reflected beam can be realized by an analyzer at fixed orientation. We developed this method for investigations of thin cryogenic films inside a vacuum chamber, where the analyzer and detector had to be placed inside the cold shield at a temperature of T approx. 90K close to the substrate. All other optical components were installed at the incoming beam line outside the vacuum chamber, including all components which need to be rotated during the measurements. Our null ellipsometry variant has been tested with condensed krypton films on a highly oriented pyrolytic graphite substrate (HOPG) at a temperature of T approx. 25K. We show that it is possible to determine the indices of refraction of condensed krypton and of the HOPG substrate as well as thickness of krypton films with reasonable accuracy.

physics.optics↗

Limits on the release of Rb isotopes from a zeolite based 83mKr calibration source for the XENON project

The isomer 83mKr with its half-life of 1.83 h is an ideal calibration source for a liquid noble gas dark matter experiment like the XENON project. However, the risk of contamination of the detector with traces of the much longer lived mother isotop 83Rb (86.2 d half-life) has to be ruled out. In this work the release of 83Rb atoms from a 1.8 MBq 83Rb source embedded in zeolite beads has been investigated. To do so, a cryogenic trap has been connected to the source for about 10 days, after which it was removed and probed for the strongest 83Rb gamma-rays with an ultra-sensitive Germanium detector. No signal has been found. The corresponding upper limit on the released 83Rb activity means that the investigated type of source can be used in the XENON project and similar low-background experiments as 83mKr generator without a significant risk of contaminating the detector. The measurements also allow to set upper limits on the possible release of the isotopes 84Rb and 86Rb, traces of which were created alongside the production of 83Rb at the Rez cyclotron.

astro-ph.IM↗

Prototype of an angular-selective photoelectron calibration source for the KATRIN experiment

The method of direct neutrino mass determination based on the kinematics of tritium beta decay, which is adopted by the KATRIN experiment, makes use of a large, high-resolution electrostatic spectrometer with magnetic adiabatic collimation. In order to target a sensitivity on the neutrino mass of 0.2 eV/c^2, a detailed understanding of the electromagnetic properties of the electron spectrometer is essential, requiring comprehensive calibration measurements with dedicated electron sources. In this paper we report on a prototype of a photoelectron source providing a narrow energy spread and angular selectivity. Both are key properties for the characterisation of the spectrometer. The angular selectivity is achieved by applying non-parallel strong electric and magnetic fields: Directly after being created, photoelectrons are accelerated rapidly and non-adiabatically by a strong electric field before adiabatic magnetic guiding takes over.

physics.ins-det↗

Effect of a sweeping conductive wire on electrons stored in the Penning trap between the KATRIN spectrometers

The KATRIN experiment is going to search for the mass of the electron antineutrino down to 0.2 eV/c^2. In order to reach this sensitivity the background rate has to be understood and minimised to 0.01 counts per second. One of the background sources is the unavoidable Penning trap for electrons due to the combination of the electric and magnetic fields between the pre- and the main spectrometer at KATRIN. In this article we will show that by sweeping a conducting wire periodically through such a particle trap stored particles can be removed, an ongoing discharge in the trap can be stopped, and the count rate measured with a detector looking at the trap is reduced.

physics.ins-det↗