SearcharxivSearch

arXiv subjects

H. A. Torii

Publications and source records attributed to H. A. Torii.

10 recordsLinked to original sources

Improved Measurements of Muonic Helium Ground-State Hyperfine Structure at a Near-Zero Magnetic Field

Muonic helium atom hyperfine structure (HFS) measurements are a sensitive tool to test the three-body atomic system and bound-state quantum electrodynamics theory, and determine fundamental constants of the negative muon magnetic moment and mass. The world's most intense pulsed negative muon beam at the Muon Science Facility of the Japan Proton Accelerator Research Complex allows improvement of previous measurements and testing further $CPT$ invariance by comparing the magnetic moments and masses of positive and negative muons (second-generation leptons). We report new ground-state HFS measurements of muonic helium-4 atoms at a near-zero magnetic field, performed for the first time using a small admixture of CH$_{4}$ as an electron donor to form neutral muonic helium atoms efficiently. Our analysis gives $Δν$ = 4464.980(20) MHz (4.5 ppm), which is more precise than both previous measurements at weak and high fields. The muonium ground-state HFS was also measured under the same conditions to investigate the isotopic effect on the frequency shift due to the gas density dependence in He with CH$_{4}$ admixture and compared with previous studies. Muonium and muonic helium can be regarded as light and heavy hydrogen isotopes with an isotopic mass ratio of 36. No isotopic effect was observed within the current experimental precision.

physics.atom-ph

Development of microwave cavities for measurement of muonium hyperfine structure at J-PARC

The MuSEUM collaboration is planning measurements of the ground-state hyperfine structure (HFS) of muonium at the Japan Proton Accelerator Research Complex (J-PARC), Materials and Life Science Experimental Facility. The high-intensity beam that will soon be available at H-line allows for more precise measurements by one order of magnitude. We plan to conduct two staged measurements. First, we will measure the Mu-HFS in a near-zero magnetic field, and thereafter we will measure it in a strong magnetic field. We have developed two microwave cavities for this purpose. Furthermore, we evaluated systematic uncertainties from such a fluctuation of microwave fields and confirm the requirement of the microwave system, we use a microwave field distribution calculated from the finite element method.

physics.ins-det

New precise spectroscopy of the hyperfine structure in muonium with a high-intensity pulsed muon beam

A hydrogen-like atom consisting of a positive muon and an electron is known as muonium. It is a near-ideal two-body system for a precision test of bound-state theory and fundamental symmetries. The MuSEUM collaboration performed a new precision measurement of the muonium ground-state hyperfine structure at J-PARC using a high-intensity pulsed muon beam and a high-rate capable positron counter. The resonance of hyperfine transition was successfully observed at a near-zero magnetic field, and the muonium hyperfine structure interval of $ν_{\text{HFS}}$ = 4.463302(4) GHz was obtained with a relative precision of 0.9 ppm. The result was consistent with the previous ones obtained at Los Alamos National Laboratory and the current theoretical calculation. We present a demonstration of the microwave spectroscopy of muonium for future experiments to achieve the highest precision.

hep-ex

Rabi-Oscillation Spectroscopy of the Hyperfine Structure of Muonium Atoms

As a new method to determine the resonance frequency, Rabi-oscillation spectroscopy has been developed. In contrast to the conventional spectroscopy which draws the resonance curve, Rabi-oscillation spectroscopy fits the time evolution of the Rabi oscillation. By selecting the optimized frequency, it is shown that the precision is twice as good as the conventional spectroscopy with a frequency sweep. Furthermore, the data under different conditions can be treated in a unified manner, allowing more efficient measurements for systems consisting of a limited number of short-lived particles produced by accelerators such as muons. We have developed a fitting function that takes into account the spatial distribution of muonium and the spatial distribution of the microwave intensity to apply the new method to ground-state muonium hyperfine structure measurements at zero field. This was applied to the actual measurement data and the resonance frequencies were determined under various conditions. The result of our analysis gives $ν_{\rm HFS}=4\ 463\ 301.61 \pm 0.71\ {\rm kHz}$, which is the world's highest precision under zero field conditions.

hep-ex

Measurement of the Principal Quantum Number Distribution in a Beam of Antihydrogen Atoms

The ASACUSA (Atomic Spectroscopy And Collisions Using Slow Antiprotons) collaboration plans to measure the ground-state hyperfine splitting of antihydrogen in a beam at the CERN Antiproton Decelerator with initial relative precision of 10-6 or better, to test the fundamental CPT (combination of charge conjugation, parity transformation and time reversal) symmetry between matter and antimatter. This challenging goal requires a polarised antihydrogen beam with a sufficient number of antihydrogen atoms in the ground state. The first measurement of the quantum state distribution of antihydrogen atoms in a low magnetic field environment of a few mT is described. Furthermore, the data-driven machine learning analysis to identify antihydrogen events is discussed.

physics.atom-ph

J-PARC MUSE H-line optimization for the g-2 and MuHFS experiments

Significant deviation of the anomalous magnetic moment value (g-2) observed by the muon g-2 experiment should be confirmed by the other experiment. This value is experimentally determined by frequency difference observed by the g-2/EDM experiment and muon magnetic moment observed by the muonium hyperfine splitting experiment (MuHFS). Both two experiments are planned to be performed at H-line of the J-PARC/MUSE under construction. We optimized the beamline layout for each experiment with G4beamline. For both experiments, statistics is the most important, thus beamline transmission efficiency should be maximized. Especially for the g-2, the purpose of the present effort is to compromise between small beam size and small leakage field. For the MuHFS, it is crucial to minimize leakage field at around final focus position, and to get all stopped muons within good field region of MuHFS magnet. Conceptual design of the several final focusing systems will be presented. contribution (or invited paper) to NUFACT 11, XIIIth International Workshop on Neutrino Factories, Super beams and Beta beams, 1-6 August 2011, CERN and University of Geneva

physics.acc-ph

Systematic study of the decay rates of antiprotonic helium states

A systematic study of the decay rates of antiprotonic helium (\pbhef and \pbhet) at CERN AD (Antiproton Decelerator) has been made by a laser spectroscopic method. The decay rates of some of its short-lived states, namely those for which the Auger rates $γ_{\mathrm{A}}$ are much larger than their radiative decay rates ($γ_{\mathrm{rad}} \sim 1$ $μ$s$^{-1}$), were determined from the time distributions of the antiproton annihilation signals induced by laser beams, and the widths of the atomic resonance lines. The magnitude of the decay rates, especially their relation with the transition multipolarity, is discussed and compared with theoretical calculations.

physics.atom-ph

Precise laser spectroscopy of the antiprotonic helium atom and CPT test on antiproton mass and charge

We have measured twelve transition frequencies of the antiprotonic helium atom (pbar-He+) with precisions of 0.1--0.2 ppm using a laser spectroscopic method. The agreement between the experiment and theories was so good that we can put a limit on the proton-antiproton mass (or charge) difference. The new limit is expected to be much smaller than the already published value, 60 ppb.

nucl-ex

Hyperfine structure of antiprotonic helium revealed by a laser-microwave-laser resonance method

Using a newly developed laser-microwave-laser resonance method, we observed a pair of microwave transitions between hyperfine levels of the $(n,L)=(37,35)$ state of antiprotonic helium. This experiment confirms the quadruplet hyperfine structure due to the interaction of the antiproton orbital angular momentum, the electron spin and the antiproton spin as predicted by Bakalov and Korobov. The measured frequencies of $ν_{\text HF}^+ =12.89596 \pm 0.00034$ GHz and $ν_{\text HF}^- =12.92467 \pm 0.00029$ GHz agree with recent theoretical calculations on a level of $ 6 \times10^{-5}$.

physics.atom-ph

Hyperfine Structure Measurements of Antiprotonic Helium and Antihydrogen

This paper describes measurements of the hyperfine structure of two antiprotonic atoms that are planned at the Antiproton Decelerator (AD) at CERN. The first part deals with antiprotonic helium, a three-body system of alpha-particle, antiproton and electron that was previously studied at LEAR. A measurement will test existing three-body calculations and may - through comparison with these theories - determine the magnetic moment of the antiproton more precisely than currently available, thus providing a test of CPT invariance. The second system, antihydrogen, consisting of an antiproton and a positron, is planned to be produced at thermal energies at the AD. A measurement of the ground-state hyperfine splitting, which for hydrogen is one of the most accurately measured physical quantities, will directly yield a precise value for the magnetic moment of the antiproton, and also compare the internal structure of proton and antiproton through the contribution of the magnetic size of the antiproton to the ground state hyperfine splitting.

nucl-ex