SearcharxivSearch

arXiv subjects

H. E. Swanson

Publications and source records attributed to H. E. Swanson.

At least 19 recordsLinked to original sources

Larmor Power Limit for Cyclotron Radiation of Relativistic Particles in a Waveguide

Cyclotron radiation emission spectroscopy (CRES) is a modern technique for high-precision energy spectroscopy, in which the energy of a charged particle in a magnetic field is measured via the frequency of the emitted cyclotron radiation. The He6-CRES collaboration aims to use CRES to probe beyond the standard model physics at the TeV scale by performing high-resolution and low-background beta-decay spectroscopy of ${}^6\textrm{He}$ and ${}^{19}\textrm{Ne}$. Having demonstrated the first observation of individual, high-energy (0.1 -- 2.5 MeV) positrons and electrons via their cyclotron radiation, the experiment provides a novel window into the radiation of relativistic charged particles in a waveguide via the time-derivative (slope) of the cyclotron radiation frequency, $\mathrm{d}f_\textrm{c}/\mathrm{d}t$. We show that analytic predictions for the total cyclotron radiation power emitted by a charged particle in circular and rectangular waveguides are approximately consistent with the Larmor formula, each scaling with the Lorentz factor of the underlying $e^\pm$ as $γ^4$. This hypothesis is corroborated with experimental CRES slope data.

nucl-ex

Short-range tests of the equivalence principle

We tested the equivalence principle at short length scales by rotating a 3-ton $^{238}$U attractor around a compact torsion balance containing Cu and Pb test bodies. The observed differential acceleration of the test bodies toward the attractor, $a_{\text{Cu}}-a_{\text{Pb}} =(1.0\pm2.8)\times 10^{-13}$ cm/s$^2$, should be compared to the corresponding gravitational acceleration of $9.2\times10^{-5}$ cm/s$^2$. Our results set new constraints on equivalence-principle violating interactions with Yukawa ranges down to 1 cm, and improve by substantial factors existing limits for ranges between 10 km and 1000 km. Our data also set strong constraints on certain power law potentials that can arise from two-boson exchange processes.

gr-qc

First observation of cyclotron radiation from MeV-scale ${\rm e}^{pm}$ following nuclear beta decay

We present an apparatus for detection of cyclotron radiation that allows a frequency-based beta energy determination in the 5 keV to 5 MeV range, characteristic of nuclear beta decays. The cyclotron frequency of the radiating beta particles in a magnetic field is used to determine the beta energy precisely. Our work establishes the foundation to apply the cyclotron radiation emission spectroscopy (CRES) technique, developed by the Project 8 collaboration, far beyond the 18-keV tritium endpoint region. We report initial measurements of beta^-s from 6He and beta^+s from 19Ne decays to demonstrate the broadband response of our detection system and assess potential systematic uncertainties for beta spectroscopy over the full (MeV) energy range. This work is an important benchmark for the practical application of the CRES technique to a variety of nuclei, in particular, opening its reach to searches for evidence of new physics beyond the TeV scale via precision beta-decay measurements.

nucl-ex

$β$-nuclear-recoil correlation from $^6$He decay in a laser trap

We report the first precise measurement of a $β$-recoil correlation from a radioactive noble gas ($^6{\rm He}$) confined via a magneto-optical trap. The measurement is motivated by the search for exotic tensor-type contributions to the charged weak current. Interpreted as tensor currents with right-handed neutrinos, the measurements yield: $|C_T/C_A|^2\le 0.022$ (90\% C.L.). On the other hand, for left-handed neutrinos the limits are $0.007< C_T/C_A <0.111$~(90\%\ C.L.). The sensitivity of the present measurement is mainly limited by experimental uncertainties in determining the time response properties and the distance between the atom cloud and the micro-channel plate used for recoil ion detection.

nucl-ex

Experimental Upper Bound and Theoretical Expectations for Parity-Violating Neutron Spin Rotation in 4He

Neutron spin rotation is expected from quark-quark weak interactions in the Standard Model, which induce weak interactions among nucleons that violate parity. We present the results from an experiment searching for the effect of parity violation via the spin rotation of polarized neutrons in a liquid $^{4}$He medium. The value for the neutron spin rotation angle per unit length in $^{4}$He, $dϕ/dz =(+2.1 \pm 8.3 (stat.) \pm 2.9 (sys.))\times10^{-7}$ rad/m, is consistent with zero. The result agrees with the best current theoretical estimates of the size of nucleon-nucleon weak amplitudes from other experiments and with the expectations from recent theoretical approaches to weak nucleon-nucleon interactions. In this paper we review the theoretical status of parity violation in the $\vec{n}+^{4}$He system and discuss details of the data analysis leading to the quoted result. Analysis tools are presented that quantify systematic uncertainties in this measurement and that are expected to be essential for future measurements.

nucl-ex

High accuracy position response calibration method for a micro-channel plate ion detector

We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an {\em in situ} calibration mask, an accuracy of 8~$μ$m and a resolution of 85~$μ$m (FWHM) have been achieved for MeV-scale $α$ particles and ions with energies of $\sim$10~keV. At this level of accuracy, the difference between the MCP position responses to high-energy $α$ particles and low-energy ions is significant. The improved performance of the MCP detector can find applications in many fields of AMO and nuclear physics. In our case, it helps reducing systematic uncertainties in a high-precision nuclear $β$-decay experiment.

physics.ins-det

Weak Interaction Studies with 6He

The 6He nucleus is an ideal candidate to study the weak interaction. To this end we have built a high-intensity source of 6He delivering ~10^10 atoms/s to experiments. Taking full advantage of that available intensity we have performed a high-precision measurement of the 6He half-life that directly probes the axial part of the nuclear Hamiltonian. Currently, we are preparing a measurement of the beta-neutrino angular correlation in 6He beta decay that will allow to search for new physics beyond the Standard Model in the form of tensor currents.

nucl-ex

Precision Measurement of the 6He Half-Life and the Weak Axial Current in Nuclei

Studies of 6He beta decay along with tritium can play an important role in testing ab-initio nuclear wave-function calculations and may allow for fixing low-energy constants in effective field theories. Here, we present an improved determination of the 6He half-life to a relative precision of 3x10^(-4). Our value of 806.89 \pm 0.11(stat)^{+0.23}_{-0.19}(syst) ms resolves a major discrepancy between previous measurements. Calculating the statistical rate function we determined the ft-value to be 803.04 ^{+0.26}_{-0.23} s. The extracted Gamow-Teller matrix element agrees within a few percent with ab-initio calculations.

nucl-ex

Laser Ranging to the Lost Lunokhod~1 Reflector

In 1970, the Soviet Lunokhod 1 rover delivered a French-built laser reflector to the Moon. Although a few range measurements were made within three months of its landing, these measurements---and any that may have followed---are unpublished and unavailable. The Lunokhod 1 reflector was, therefore, effectively lost until March of 2010 when images from the Lunar Reconnaissance Orbiter (LRO) provided a positive identification of the rover and determined its coordinates with uncertainties of about 100 m. This allowed the Apache Point Observatory Lunar Laser-ranging Operation (APOLLO) to quickly acquire a laser signal. The reflector appears to be in excellent condition, delivering a signal roughly four times stronger than its twin reflector on the Lunokhod 2 rover. The Lunokhod 1 reflector is especially valuable for science because it is closer to the Moon's limb than any of the other reflectors and, unlike the Lunokhod 2 reflector, we find that it is usable during the lunar day. We report the selenographic position of the reflector to few-centimeter accuracy, comment on the health of the reflector, and illustrate the value of this reflector for achieving science goals.

astro-ph.EP

Long-term degradation of optical devices on the moon

Forty years ago, Apollo astronauts placed the first of several retroreflector arrays on the lunar surface. Their continued usefulness for laser-ranging might suggest that the lunar environment does not damage optical devices. However, new laser ranging data reveal that the efficiency of the three Apollo reflector arrays is now diminished by a factor of ten at all lunar phases and by an additional factor of ten when the lunar phase is near full moon. These deficits did not exist in the earliest years of lunar ranging, indicating that the lunar environment damages optical equipment on the timescale of decades. Dust or abrasion on the front faces of the corner-cube prisms may be responsible, reducing their reflectivity and degrading their thermal performance when exposed to face-on sunlight at full moon. These mechanisms can be tested using laboratory simulations and must be understood before designing equipment destined for the moon.

astro-ph.EP

A liquid helium target system for a measurement of parity violation in neutron spin rotation

A liquid helium target system was designed and built to perform a precision measurement of the parity-violating neutron spin rotation in helium due to the nucleon-nucleon weak interaction. The measurement employed a beam of low energy neutrons that passed through a crossed neutron polarizer--analyzer pair with the liquid helium target system located between them. Changes between the target states generated differences in the beam transmission through the polarizer--analyzer pair. The amount of parity-violating spin rotation was determined from the measured beam transmission asymmetries. The expected parity-violating spin rotation of order $10^{-6}$ rad placed severe constraints on the target design. In particular, isolation of the parity-odd component of the spin rotation from a much larger background rotation caused by magnetic fields required that a nonmagnetic cryostat and target system be supported inside the magnetic shielding, while allowing nonmagnetic motion of liquid helium between separated target chambers. This paper provides a detailed description of the design, function, and performance of the liquid helium target system.

nucl-ex

Electron-capture branch of 100Tc and tests of nuclear wave functions for double-beta decays

We present a measurement of the electron-capture branch of $^{100}$Tc. Our value, $B(\text{EC}) = (2.6 \pm 0.4) \times 10^{-5}$, implies that the $^{100}$Mo neutrino absorption cross section to the ground state of $^{100}$Tc is roughly one third larger than previously thought. Compared to previous measurements, our value of $B(\text{EC})$ prevents a smaller disagreement with QRPA calculations relevant to double-$β$ decay matrix elements.

nucl-ex

APOLLO: the Apache Point Observatory Lunar Laser-ranging Operation: Instrument Description and First Detections

A next-generation lunar laser ranging apparatus using the 3.5 m telescope at the Apache Point Observatory in southern New Mexico has begun science operation. APOLLO (the Apache Point Observatory Lunar Laser-ranging Operation) has achieved one-millimeter range precision to the moon which should lead to approximately one-order-of-magnitude improvements in the precision of several tests of fundamental properties of gravity. We briefly motivate the scientific goals, and then give a detailed discussion of the APOLLO instrumentation.

astro-ph

Tests of the Gravitational Inverse-Square Law below the Dark-Energy Length Scale

We conducted three torsion-balance experiments to test the gravitational inverse-square law at separations between 9.53 mm and 55 micrometers, probing distances less than the dark-energy length scale $λ_{\rm d}=\sqrt[4]{\hbar c/ρ_{\rm d}}\approx 85 μ$m. We find with 95% confidence that the inverse-square law holds ($|α| \leq 1$) down to a length scale $λ= 56 μ$m and that an extra dimension must have a size $R \leq 44 μ$m.

hep-ph

Sub-millimeter Tests of the Gravitational Inverse-square Law

Motivated by a variety of theories that predict new effects, we tested the gravitational 1/r^2 law at separations between 10.77 mm and 137 microns using two different 10-fold azimuthally symmetric torsion pendulums and rotating 10-fold symmetric attractors. Our work improves upon other experiments by up to a factor of about 100. We found no deviation from Newtonian physics at the 95% confidence level and interpret these results as constraints on extensions of the Standard Model that predict Yukawa or power-law forces. We set a constraint on the largest single extra dimension (assuming toroidal compactification and that one extra dimension is significantly larger than all the others) of R <= 160 microns, and on two equal-sized large extra dimensions of R <= 130 microns. Yukawa interactions with |alpha| >= 1 are ruled out at 95% confidence for lambda >= 197 microns. Extra-dimensions scenarios stabilized by radions are restricted to unification masses M >= 3.0 TeV/c^2, regardless of the number of large extra dimensions. We also provide new constraints on power-law potentials V(r)\propto r^{-k} with k between 2 and 5 and on the gamma_5 couplings of pseudoscalars with m <= 10 meV/c^2.

hep-ph

Precise measurement of the ^7Be(p,gamma)^8B S-factor

We present new measurements of the ^7Be(p,gamma)^8B cross section from \bar{E}_{cm} = 116 to 2460 keV, that incorporate several improvements over our previously published experiment, also discussed here. Our new measurements lead to S_{17}(0) = 22.1 +- 0.6(expt) +- 0.6(theor) eV b based on data from \bar{E}_{cm} = 116 to 362 keV, where the central value is based on the theory of Descouvemont and Baye. The theoretical error estimate is based on the fit of 12 different theories to our low energy data. We compare our results to other S_{17}(0) values extracted from both direct (^7Be(p,gamma)^8B) and indirect (Coulomb dissociation and heavy-ion reaction) measurements, and show that the results of these 3 types of experiments are not mutually compatible. We recommend a "best" value, S_{17}(0) = 21.4 +- 0.5(expt) +- 0.6(theor) eV b, based on the mean of all modern direct measurements below the 1^+ resonance. We also present S-factors at 20 keV which is near the center of the Gamow window: the result of our measurements is S_{17}(20) = 21.4 +- 0.6(expt) +- 0.6(theor) eV b, and the recommended value is S_{17}(20) = 20.7 +- 0.5(expt) +- 0.6(theor) eV b.

nucl-ex

7Be(p,gamma)8B astrophysical S-factor from precision cross section measurements

We measured the 7Be(p,gamma)8B cross section from E_cm = 186 to 1200 keV, with a statistical-plus-systematic precision per point of better than +- 5%. All important systematic errors were measured including 8B backscattering losses. We obtain S_17(0) = 22.3 +- 0.7(expt) +- 0.5(theor) eV-b from our data at E_cm <= 300 keV and the theory of Descouvemont and Baye.

nucl-ex