Mapper of the IGM spin temperature: instrument overview

The observation of the global 21 cm signal produced by neutral hydrogen gas in the intergalactic medium (IGM) during the Dark Ages, Cosmic Dawn, and Epoch of Reionization requires measurements with extremely well-calibrated wideband radiometers. We describe the design and characterization of the Mapper of the IGM Spin Temperature (MIST), which is a new ground-based, single-antenna, global 21 cm experiment. The design of MIST was guided by the objectives of avoiding systematics from an antenna ground plane and cables around the antenna, as well as maximizing the instrument's on-sky efficiency and portability for operations at remote sites. We have built two MIST instruments, which observe in the range 25-105 MHz. For the 21 cm signal, this frequency range approximately corresponds to redshifts 55.5 > z > 12.5, encompassing the Dark Ages and Cosmic Dawn. The MIST antenna is a horizontal blade dipole of 2.42 m in length, 60 cm in width, and 52 cm in height above the ground. This antenna operates without a metal ground plane. The instruments run on 12 V batteries and have a maximum power consumption of 17 W. The batteries and electronics are contained in a single receiver box located under the antenna. We present the characterization of the instruments using electromagnetic simulations and lab measurements. We also show sample sky measurements from recent observations at remote sites in California, Nevada, and the Canadian High Arctic. These measurements indicate that the instruments perform as expected. Detailed analyses of the sky measurements are left for future work.

astro-ph.IM

CONCERTO at APEX: Installation and first phase of on-sky commissioning

CONCERTO (CarbON CII line in post-rEionisation and ReionisaTiOn) is a large field-of-view (FoV) spectro-imager that has been installed on the Cassegrain Cabin of Atacama Pathfinder EXperiment (APEX) telescope in April 2021. CONCERTO hosts 2 focal planes and a total number of 4000 Kinetic Inductance Detectors (KID), with an instantaneous FoV of 18.6 arcminutes in the range of 130-310 GHz. The spectral resolution can be easily tuned down to 1 GHz depending on the scientific target. The scientific program of CONCERTO has many objectives, with two main programs focused on mapping the fluctuations of the [CII] line intensity in the reionisation and post-reionisation epoch (4.5<z<8.5), and on studying galaxy clusters via the thermal and kinetic Sunyaev-Zel'dovich (SZ) effect. CONCERTO will also measure the dust and molecular gas contents of local and intermediate-redshift galaxies, it will study the Galactic star-forming clouds and finally it will observe the CO intensity fluctuations arising from 0.3<z<2 galaxies. The design of the instrument, installation at APEX and current status of the commissioning phase and science verification will be presented. Also we describe the deployment and first on-sky tests performed between April and June 2021.

astro-ph.IM

A wide field-of-view low-resolution spectrometer at APEX: instrument design and science forecast

Characterise the large-scale structure in the Universe from present times to the high redshift epoch of reionisation is essential to constraining the cosmology, the history of star formation and reionisation, measuring the gas content of the Universe and obtaining a better understanding of the physical process that drive galaxy formation and evolution. Using the integrated emission from unresolved galaxies or gas clouds, line intensity mapping (LIM) provides a new observational window to measure the larger properties of structure. This very promising technique motivates the community to plan for LIM experiments. We describe the development of a large field-of-view instrument, named CONCERTO, operating in the range 130-310 GHz from the APEX 12-meters telescope. CONCERTO is a low-resolution spectrometer based on the Lumped Element Kinetic Inductance Detectors technology. Spectra are obtained using a fast Fourier Transform Spectrometer (FTS), coupled to a dilution cryostat with base temperature of 0.1K. Two 2 kilo-pixels arrays of LEKID are mounted inside the cryostat that also contains the cold optics and the front-end electronics. We present in detail the technological choices leading to the instrumental concept, together with the design and fabrication of the instrument and preliminary laboratory tests on the detectors. We also give our best estimates of CONCERTO sensitivity and give predictions for two of the main scientific goals of CONCERTO, i.e. a [CII]-intensity mapping survey and observations of galaxy clusters. We provide a detail description of the instrument design. Based on realistic comparisons with existing instruments developed by our group (NIKA, NIKA2, and KISS), and on laboratory detectors characterisation, we provide an estimate of CONCERTO sensitivity on sky. Finally, we describe in detail two out of the main science goals offered by CONCERTO at APEX.

astro-ph.IM

Demonstration of microwave multiplexed readout of DC biased superconducting nanowire detectors

Superconducting nanowires are widely used as sensitive single photon detectors with wide spectral coverage and high timing resolution. We describe a demonstration of an array of DC biased superconducting nanowire single photon detectors read out with a microwave multiplexing circuit. In this design, each individual nanowire is part of a resonant LC circuit where the inductance is dominated by the kinetic inductance of the nanowire. The circuit also contains two parallel plate capacitors, one of them is in parallel with the inductor and the other is coupled to a microwave transmission line which carries the signals to a cryogenic low noise amplifier. All of the nanowires are connected via resistors to a single DC bias line that enables the nanowires to be current biased close to their critical current. When a photon hits a nanowire it creates a normal hot spot which produces a voltage pulse across the LC circuit. This pulse rings down at the resonant frequency of the LC circuit over a time period that is fixed by the quality factor. We present measurements of an array of these devices and an evaluation of their performance in terms of frequency and time response.

physics.ins-det

Kinetic Inductance Detectors and readout electronics for the OLIMPO experiment

Kinetic Inductance Detectors (KIDs) are superconductive low$-$temperature detectors useful for astrophysics and particle physics. We have developed arrays of lumped elements KIDs (LEKIDs) sensitive to microwave photons, optimized for the four horn-coupled focal planes of the OLIMPO balloon-borne telescope, working in the spectral bands centered at 150 GHz, 250 GHz, 350 GHz, and 460 GHz. This is aimed at measuring the spectrum of the Sunyaev-Zel'dovich effect for a number of galaxy clusters, and will validate LEKIDs technology in a space-like environment. Our detectors are optimized for an intermediate background level, due to the presence of residual atmosphere and room--temperature optical system and they operate at a temperature of 0.3 K. The LEKID planar superconducting circuits are designed to resonate between 100 and 600 MHz, and to match the impedance of the feeding waveguides; the measured quality factors of the resonators are in the $10^{4}-10^{5}$ range, and they have been tuned to obtain the needed dynamic range. The readout electronics is composed of a $cold$ $part$, which includes a low noise amplifier, a dc$-$block, coaxial cables, and power attenuators; and a $room-temperature$ $part$, FPGA$-$based, including up and down-conversion microwave components (IQ modulator, IQ demodulator, amplifiers, bias tees, attenuators). In this contribution, we describe the optimization, fabrication, characterization and validation of the OLIMPO detector system.