Searcharxiv⌕ Search

arXiv subjects

H. Natal da Luz

Publications and source records attributed to H. Natal da Luz.

At least 19 recordsLinked to original sources

Double-GEM based thermal neutron detector prototype

The Helium-3 shortage and the growing interest in neutron science constitute a driving factor in developing new neutron detection technologies. In this work, we report the development of a double-GEM detector prototype that uses a $^{10}$B$_4$C layer as a neutron converter material. GEANT4 simulations were performed predicting an efficiency of 3.14(10) %, agreeing within 2.7 $σ$ with the experimental and analytic detection efficiencies obtained by the detector when tested in a 41.8 meV thermal neutron beam. The detector is position sensitive, equipped with a 256+256 strip readout connected to resistive chains, and achieves a spatial resolution better than 3 mm. The gain stability over time was also measured with a fluctuation of about 0.2 %h$^{-1}$ of the signal amplitude. A simple data acquisition with only 5 electronic channels is sufficient to operate this detector.

physics.ins-det↗

Snowmass 2021 White Paper Instrumentation Frontier 05 -- White Paper 1: MPGDs: Recent advances and current R&D

This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51 collaboration which has become the critical organization for the promotion of MPGDs and all aspects of their production, characterization, simulation, and uses in an expanding array of experimental configurations. For the Snowmass 2021 study, a number of Letters of Interest were received that illustrate ongoing developments and expansion of the use of MPGDs. In this paper, we highlight high precision timing, high rate application, trigger capability expansion of the SRS readout system, and a structure designed for low ion backflow.

physics.ins-det↗

Ion backflow studies with a triple-GEM stack with increasing hole pitch

Gas Electron Multipliers have undergone a very consistent development since their invention in 1997. Their production procedures have been tuned in such a way that nowadays it is possible to produce foils with areas of the order of the square meter that can operate at a reasonable gain, uniform over large areas and with a good stability in what concerns electrical discharges. For the third run of LHC, they will be included in the CMS and ALICE experiments after significant upgrades of the detectors, confirming that these structures are suitable for very large experiments. In the special case of Time Projection Chambers, the ion backflow and the energy resolution are sensitive issues that must be addressed and the GEM has shown to be able to deal with both of them. In this work, a stack of three GEMs with different pitches has been studied as a possible future approach for ion-backflow suppression to be used in TPCs and other detection concepts. With this approach, an ion backflow of 1 % with an energy resolution of 12 % at 5.9 keV has been achieved with the detector operating in an Ar/CO2 (90/10) mixture at a gain of ~ 2000.

physics.ins-det↗

Gain characteristics of a 100 micrometer thick GEM in Krypton-CO2 mixtures

The operation of a Micropattern Gaseous Detector (MPGD) comprising a cascade of two non-standard Gas Electron Multipliers (GEM) made from a 100 micrometer kapton foil was evaluated in pure krypton and in krypton-CO2 mixtures. The final avalanche charge was collected in a 2D strip readout, providing an active area of 10x10 cm2 for the entire detection system. For each mixture, the effective gain and energy resolution were measured as a function of the electric field in the drift, transfer and induction regions. Using X-rays from a 55Fe radioactive source (5.9 keV), gains close to 104 and energy resolution of 22% (FWHM) were achieved in pure krypton under stable conditions, showing the potential of the experimental setup for the following imaging studies.

physics.ins-det↗

First in-beam studies of a Resistive-Plate WELL gaseous multiplier

We present the results of the first in-beam studies of a medium size (10$\times$10 cm$^2$) Resistive-Plate WELL (RPWELL): a single-sided THGEM coupled to a pad anode through a resistive layer of high bulk resistivity ($\sim$10$^9 Ω$cm). The 6.2~mm thick (excluding readout electronics) single-stage detector was studied with 150~GeV muons and pions. Signals were recorded from 1$\times$1 cm$^2$ square copper pads with APV25-SRS readout electronics. The single-element detector was operated in Ne\(5% $\mathrm{CH_{4}}$) at a gas gain of a few times 10$^4$, reaching 99$\%$ detection efficiency at average pad multiplicity of $\sim$1.2. Operation at particle fluxes up to $\sim$10$^4$ Hz/cm$^2$ resulted in $\sim$23$\%$ gain drop leading to $\sim$5$\%$ efficiency loss. The striking feature was the discharge-free operation, also in intense pion beams. These results pave the way towards robust, efficient large-scale detectors for applications requiring economic solutions at moderate spatial and energy resolutions.

physics.ins-det↗

Ionization and scintillation of nuclear recoils in gaseous xenon

Ionization and scintillation produced by nuclear recoils in gaseous xenon at approximately 14 bar have been simultaneously observed in an electroluminescent time projection chamber. Neutrons from radioisotope $α$-Be neutron sources were used to induce xenon nuclear recoils, and the observed recoil spectra were compared to a detailed Monte Carlo employing estimated ionization and scintillation yields for nuclear recoils. The ability to discriminate between electronic and nuclear recoils using the ratio of ionization to primary scintillation is demonstrated. These results encourage further investigation on the use of xenon in the gas phase as a detector medium in dark matter direct detection experiments.

physics.ins-det↗

X-ray imaging with GEMs using $100\,μ$m thick foils

A simple X-ray imaging system using off-the-shelf electronics and simple reconstruction algorithms aiming a spatial resolution of 1.7 mm ($\sim 3\,\%$ of the detector length) is described in this work. For this, two 100 cm$^2$ Gas Electron Multiplier (GEM) foils with a thickness of 100 μm (2-fold thicker than the standard ones) were immersed in a mixture of argon and carbon dioxide (70:30). The charge readout with 2D position determination was done with resistive charge division. Due to their higher thickness with respect to the standard GEMs, the 100 μm thick GEM foils were found to be less prone to damage caused by the electrical discharges. X-ray images are shown and some descriptions of the physical processes involved are presented. We describe the advantages of this method that allows counting each X-ray photon or particle entering the detector, its interaction position, as well as measuring of its energy. The results of our present work show a position resolution below 2 mm, being limited by the gas mixture used, and not the detecting system, with a very good cost effectiveness. Future work is being carried out to optimize the present system for a medical application as a proton beam monitor.

physics.ins-det↗

Description and commissioning of NEXT-MM prototype: first results from operation in a Xenon-Trimethylamine gas mixture

A technical description of NEXT-MM and its commissioning and first performance is reported. Having an active volume of ~35 cm drift $\times$ 28 cm diameter, it constitutes the largest Micromegas-read TPC operated in Xenon ever constructed, made by a sectorial arrangement of the 4 largest single wafers manufactured with the Microbulk technique to date. It is equipped with a suitably pixelized readout and with a sufficiently large sensitive volume (~23 l) so as to contain long (~20 cm) electron tracks. First results obtained at 1 bar for Xenon and trimethylamine (Xe-(2 %)TMA) mixture are presented. The TPC can accurately reconstruct extended background tracks. An encouraging full-width half-maximum of 11.6 % was obtained for ~29 keV gammas without resorting to any data post-processing.

physics.ins-det↗

Characterization of a medium size Xe/TMA TPC instrumented with microbulk Micromegas, using low-energy $γ$-rays

NEXT-MM is a general-purpose high pressure (10 bar, $\sim25$ l active volume) Xenon-based TPC, read out in charge mode with an 8 cm $\times$8 cm-segmented 700 cm$^2$ plane (1152 ch) of the latest microbulk-Micromegas technology. It has been recently commissioned at University of Zaragoza as part of the R&D of the NEXT $0νββ$ experiment, although the experiment's first stage is currently being built based on a SiPM/PMT-readout concept relying on electroluminescence. Around 2 million events were collected during the last months, stemming from the low energy $γ$-rays emitted by a $^{241}$Am source when interacting with the Xenon gas ($ε$ = 26, 30, 59.5 keV). The localized nature of such events above atmospheric pressure, the long drift times, as well as the possibility to determine their production time from the associated $α$ particle in coincidence, allow the extraction of primordial properties of the TPC filling gas, namely the drift velocity, diffusion and attachment coefficients. In this work we focus on the little explored combination of Xe and trimethylamine (TMA) for which, in particular, such properties are largely unknown. This gas mixture offers potential advantages over pure Xenon when aimed at Rare Event Searches, mainly due to its Penning characteristics, wave-length shifting properties and reduced diffusion, and it is being actively investigated by our collaboration. The chamber is currently operated at 2.7 bar, as an intermediate step towards the envisaged 10 bar. We report here its performance as well as a first implementation of the calibration procedures that have allowed the extension of the previously reported energy resolution to the whole readout plane (10.6%FWHM@30keV).

physics.ins-det↗

Present status and future perspectives of the NEXT experiment

NEXT is an experiment dedicated to neutrinoless double beta decay searches in xenon. The detector is a TPC, holding 100 kg of high-pressure xenon enriched in the $^{136}$Xe isotope. It is under construction in the Laboratorio Subterráneo de Canfranc in Spain, and it will begin operations in 2015. The NEXT detector concept provides an energy resolution better than 1% FWHM and a topological signal that can be used to reduce the background. Furthermore, the NEXT technology can be extrapolated to a 1-ton scale experiment.

physics.ins-det↗

Beam studies of novel THGEM-based potential sampling elements for Digital Hadron Calorimetry

Beam studies of thin single- and double-stage THGEM-based detectors are presented. Several 10 x 10 cm^2 configurations with a total thickness of 5-6 mm (excluding readout electronics), with 1 x 1 cm^2 pads inductively coupled through a resistive layer to APV-SRS readout electronics, were investigated with muons and pions. Detection efficiencies in the 98% range were recorded with an average pad-multiplicity of ~1.1. The resistive anode resulted in efficient discharge damping, with few-volt potential drops; discharge probabilities were ~10^{-7} for muons and 10^{-6} for pions in the double-stage configuration, at rates of a few kHz/cm^2. These results, together with the robustness of THGEM electrodes against spark damage and their suitability for economic production over large areas make THGEM-based detectors highly competitive compared to the other technologies considered for the SiD-DHCAL.

physics.ins-det↗

Operation and first results of the NEXT-DEMO prototype using a silicon photomultiplier tracking array

NEXT-DEMO is a high-pressure xenon gas TPC which acts as a technological test-bed and demonstrator for the NEXT-100 neutrinoless double beta decay experiment. In its current configuration the apparatus fully implements the NEXT-100 design concept. This is an asymmetric TPC, with an energy plane made of photomultipliers and a tracking plane made of silicon photomultipliers (SiPM) coated with TPB. The detector in this new configuration has been used to reconstruct the characteristic signature of electrons in dense gas. Demonstrating the ability to identify the MIP and "blob" regions. Moreover, the SiPM tracking plane allows for the definition of a large fiducial region in which an excellent energy resolution of 1.82% FWHM at 511 keV has been measured (a value which extrapolates to 0.83% at the xenon Qbetabeta).

physics.ins-det↗

Ionization and scintillation response of high-pressure xenon gas to alpha particles

High-pressure xenon gas is an attractive detection medium for a variety of applications in fundamental and applied physics. In this paper we study the ionization and scintillation detection properties of xenon gas at 10 bar pressure. For this purpose, we use a source of alpha particles in the NEXT-DEMO time projection chamber, the large scale prototype of the NEXT-100 neutrinoless double beta decay experiment, in three different drift electric field configurations. We measure the ionization electron drift velocity and longitudinal diffusion, and compare our results to expectations based on available electron scattering cross sections on pure xenon. In addition, two types of measurements addressing the connection between the ionization and scintillation yields are performed. On the one hand we observe, for the first time in xenon gas, large event-by-event correlated fluctuations between the ionization and scintillation signals, similar to that already observed in liquid xenon. On the other hand, we study the field dependence of the average scintillation and ionization yields. Both types of measurements may shed light on the mechanism of electron-ion recombination in xenon gas for highly-ionizing particles. Finally, by comparing the response of alpha particles and electrons in NEXT-DEMO, we find no evidence for quenching of the primary scintillation light produced by alpha particles in the xenon gas.

physics.ins-det↗

Initial results of NEXT-DEMO, a large-scale prototype of the NEXT-100 experiment

NEXT-DEMO is a large-scale prototype of the NEXT-100 detector, an electroluminescent time projection chamber that will search for the neutrinoless double beta decay of Xe-136 using 100 to 150 kg of enriched xenon gas. NEXT-DEMO was built to prove the expected performance of NEXT-100, namely, energy resolution better than 1% FWHM at 2.5 MeV and event topological reconstruction. In this paper we describe the prototype and its initial results. A resolution of 1.75% FWHM at 511 keV (which extrapolates to 0.8% FWHM at 2.5 MeV) was obtained at 10 bar pressure using a gamma-ray calibration source. Also, a basic study of the event topology along the longitudinal coordinate is presented, proving that it is possible to identify the distinct dE/dx of electron tracks in high-pressure xenon using an electroluminescence TPC.

physics.ins-det↗

Design and characterization of the SiPM tracking system of NEXT-DEMO, a demonstrator prototype of the NEXT-100 experiment

NEXT-100 experiment aims at searching the neutrinoless double-beta decay of the Xe-136 isotope using a TPC filled with a 100 kg of high-pressure gaseous xenon, with 90% isotopic enrichment. The experiment will take place at the Laboratorio Subterráneo de Canfranc (LSC), Spain. NEXT-100 uses electroluminescence (EL) technology for energy measurement with a resolution better than 1% FWHM. The gaseous xenon in the TPC additionally allows the tracks of the two beta particles to be recorded, which are expected to have a length of up to 30 cm at 10 bar pressure. The ability to record the topological signature of the neutrinoless double-beta events provides a powerful background rejection factor for the double-beta experiment. In this paper, we present a novel 3D imaging concept using SiPMs coated with tetraphenyl butadiene (TPB) for the EL read out and its first implementation in NEXT-DEMO, a large-scale prototype of the NEXT-100 experiment. The design and the first characterization measurements of the NEXT-DEMO SiPM tracking system are presented. The SiPM response uniformity over the tracking plane drawn from its gain map is shown to be better than 4%. An automated active control system for the stabilization of the SiPMs gain was developed, based on the voltage supply compensation of the gain drifts. The gain is shown to be stabilized within 0.2% relative variation around its nominal value, provided by Hamamatsu, in a temperature range of 10 degree C. The noise level from the electronics and the SiPM dark noise is shown to lay typically below the level of 10 photoelectrons (pe) in the ADC. Hence, a detection threshold at 10 pe is set for the acquisition of the tracking signals. The ADC full dynamic range (4096 channels) is shown to be adequate for signal levels of up to 200 pe/microsecond, which enables recording most of the tracking signals.

physics.ins-det↗

Radiopurity control in the NEXT-100 double beta decay experiment: procedures and initial measurements

The Neutrino Experiment with a Xenon TPC (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds. An extensive screening and material selection process is underway for NEXT since the control of the radiopurity levels of the materials to be used in the experimental set-up is a must for rare event searches. First measurements based on Glow Discharge Mass Spectrometry and gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterráneo de Canfranc (Spain) are described here. Activity results for natural radioactive chains and other common radionuclides are summarized, being the values obtained for some materials like copper and stainless steel very competitive. The implications of these results for the NEXT experiment are also discussed.

physics.ins-det↗

In-situ calibration of a PMT inside a scintillation detector by means of primary scintillation detection

We have investigated the possibility of calibrating the PMTs of scintillation detectors, using the primary scintillation produced by X-rays to induce single photoelectron response of the PMT. The high-energy tail of this response, can be approximated to an exponential function, under some conditions. In these cases, it is possible to determine the average gain for each PMT biasing voltage from the inverse of the exponent of the exponential fit to the tail, which can be done even if the background and/or noise cover-up most of the distribution. We have compared our results with those obtained by the commonly used single electron response (SER) method, which uses a LED to induce a single photoelectron response of the PMT and determines the peak position of such response, relative to the pedestal peak (the electronic noise peak, which corresponds to 0 photoelectrons). The results of the exponential fit method agree with those obtained by the SER method when the average number of photoelectrons reaching the first dynode per light/scintillation pulse is around 1.0. The SER method has higher precision, while the exponential fit method has the advantage of being useful in situations where the PMT is already in situ, being difficult or even impossible to apply the SER method, e.g. in sealed scintillator/PMT devices.

physics.ins-det↗

Near-Intrinsic Energy Resolution for 30 to 662 keV Gamma Rays in a High Pressure Xenon Electroluminescent TPC

We present the design, data and results from the NEXT prototype for Double Beta and Dark Matter (NEXT-DBDM) detector, a high-pressure gaseous natural xenon electroluminescent time projection chamber (TPC) that was built at the Lawrence Berkeley National Laboratory. It is a prototype of the planned NEXT-100 $^{136}$Xe neutrino-less double beta decay ($0νββ$) experiment with the main objectives of demonstrating near-intrinsic energy resolution at energies up to 662 keV and of optimizing the NEXT-100 detector design and operating parameters. Energy resolutions of $\sim$1% FWHM for 662 keV gamma rays were obtained at 10 and 15 atm and $\sim$5% FWHM for 30 keV fluorescence xenon X-rays. These results demonstrate that 0.5% FWHM resolutions for the 2,459 keV hypothetical neutrino-less double beta decay peak are realizable. This energy resolution is a factor 7 to 20 better than that of the current leading $0νββ$ experiments using liquid xenon and thus represents a significant advancement. We present also first results from a track imaging system consisting of 64 silicon photo-multipliers recently installed in NEXT-DBDM that, along with the excellent energy resolution, demonstrates the key functionalities required for the NEXT-100 $0νββ$ search.

physics.ins-det↗