SearcharxivSearch

arXiv subjects

H. Shao

Publications and source records attributed to H. Shao.

4 recordsLinked to original sources

Evaluation of a $^{88}$Sr$^+$ optical clock with a direct measurement of the blackbody radiation shift and determination of the clock frequency

We report on an evaluation of an optical clock that uses the $\phantom{}^2S_{1/2} \rightarrow \phantom{}^2D_{5/2}$ transition of a single $^{88}$Sr$^+$ ion as the reference. In contrast to previous work, we estimate the effective temperature of the blackbody radiation that shifts the reference transition directly during operation from the corresponding frequency shift and the well-characterized sensitivity to thermal radiation. We measure the clock output frequency against an independent $^{171}$Yb$^+$ ion clock, based on the $\phantom{}^2S_{1/2} (F=0) \rightarrow \phantom{}^2F_{7/2} (F=3)$ electric octupole (E3) transition, and determine the frequency ratio with a total fractional uncertainty of $2.3\times 10^{-17}$. Relying on a previous measurement of the $^{171}$Yb$^+$ (E3) clock frequency, we find the absolute frequency of the $^{88}$Sr$^+$ clock transition to be $444779044095485.271(59)\,\text{Hz}$. Our result reduces the uncertainty by a factor of $3$ compared to the previously most accurate measurement and may help to resolve so far inconsistent determinations of this value. We also show that for three simultaneously interrogated $^{88}$Sr$^+$ ions, the increased number causes the expected improvement of the short-term frequency instability of the optical clock without degrading its systematic uncertainty.

physics.atom-ph

Improved limits for violations of local position invariance from atomic clock comparisons

We compare two optical clocks based on the $^2$S$_{1/2}(F=0)\to {}^2$D$_{3/2}(F=2)$ electric quadrupole (E2) and the $^2$S$_{1/2}(F=0)\to {}^2$F$_{7/2}(F=3)$ electric octupole (E3) transition of $^{171}$Yb$^{+}$ and measure the frequency ratio $ν_{\mathrm{E3}}/ν_{\mathrm{E2}}=0.932\,829\,404\,530\,965\,376(32)$. We determine the transition frequency $ν_{E3}=642\,121\,496\,772\,645.10(8)$ Hz using two caesium fountain clocks. Repeated measurements of both quantities over several years are analyzed for potential violations of local position invariance. We improve by factors of about 20 and 2 the limits for fractional temporal variations of the fine structure constant $α$ to $1.0(1.1)\times10^{-18}/\mathrm{yr}$ and of the proton-to-electron mass ratio $μ$ to $-8(36)\times10^{-18}/\mathrm{yr}$. Using the annual variation of the Sun's gravitational potential at Earth $Φ$, we improve limits for a potential coupling of both constants to gravity, $(c^2/α) (dα/dΦ)=14(11)\times 10^{-9}$ and $(c^2/μ) (dμ/dΦ)=7(45)\times 10^{-8}$.

physics.atom-ph

Coherent suppression of tensor frequency shifts through magnetic field rotation

We introduce a scheme to coherently suppress second-rank tensor frequency shifts in atomic clocks, relying on the continuous rotation of an external magnetic field during the free atomic state evolution in a Ramsey sequence. The method retrieves the unperturbed frequency within a single interrogation cycle and is readily applicable to various atomic clock systems. For the frequency shift due to the electric quadrupole interaction, we experimentally demonstrate suppression by more than two orders of magnitude for the ${}^2S_{1/2} \to {}^2D_{3/2}$ transition of a single trapped ${}^{171}\text{Yb}^+$ ion. The scheme provides particular advantages in the case of the ${}^{171}\text{Yb}^+$ ${}^2S_{1/2} \to {}^2F_{7/2}$ electric octupole (E3) transition. For an improved estimate of the residual quadrupole shift for this transition, we measure the excited state electric quadrupole moments $Θ({}^2D_{3/2}) = 1.95(1)~ea_0^2$ and $Θ({}^2F_{7/2}) = -0.0297(5)~ea_0^2$ with $e$ the elementary charge and $a_0$ the Bohr radius, improving the measurement uncertainties by one order of magnitude.

physics.atom-ph

Precision Measurement of the Quadrupole Transition Matrix Element in a Single Trapped $^{40}$Ca$^{+}$

We report the first experimental determination of the $4s \ ^{2}S_{1/2} $ $\leftrightarrow $ $3d \ ^{2}D_{5/2}$ quadrupole transition matrix element in $^{40}$Ca$^+$ by measuring the branching ratio of the $3d \ ^{2}D_{5/2} $ state decaying into the ground state $4s \ ^{2}S_{1/2} $ and the lifetime of the $3d \ ^{2}D_{5/2} $ state, using a technique of highly synchronized measurement sequence for laser control and highly efficient quantum state detection for quantum jumps. The measured branching ratio and improved lifetime are, respectively, 0.9992(80) and 1.1652(46) s, which yield the value of the quadrupole transition matrix element (in absolute value) 9.737(43)~$ea_{0}^{2}$ with the uncertainty at the level of 0.44\%. The measured quadrupole transition matrix element is in good agreement with the most precise many-body atomic structure calculations. Our method can be universally applied to measurements of transition matrix elements in single ions and atoms of similar structure.

physics.atom-ph