SearcharxivSearch

arXiv subjects

H. Sumino

Publications and source records attributed to H. Sumino.

4 recordsLinked to original sources

Improved measurements of neutron lifetime with cold neutron beam at J-PARC

The ``neutron lifetime puzzle'' arises from the discrepancy between neutron lifetime measurements obtained using the beam method, which measures decay products, and the bottle method, which measures the disappearance of neutrons. To resolve this puzzle, we conducted an experiment using a pulsed cold neutron beam at J-PARC. In this experiment, the neutron lifetime is determined from the ratio of neutron decay counts to $^3$He(n,p)$^3$H reactions in a gas detector. This experiment belongs to the beam method but differs from previous experiments that measured protons, as it instead detects electrons, enabling measurements with distinct systematic uncertainties. By enlarging the beam transport system and reducing systematic uncertainties, we achieved a fivefold improvement in precision. Analysis of all acquired data yielded a neutron lifetime of $\tau_{\rm n}=877.2~\pm~1.7_{\rm(stat.)}~^{+4.0}_{-3.6}{}_{\rm (sys.)}$ s. This result is consistent with bottle method measurements but exhibits a 2.3$\sigma$ tension with the average value obtained from the proton-detection-based beam method.

nucl-ex

Neutron lifetime measurement with pulsed cold neutrons

The neutron lifetime has been measured by comparing the decay rate with the reaction rate of $^3$He nuclei of a pulsed neutron beam from the spallation neutron source at the Japan Proton Accelerator Research Complex (J-PARC). The decay rate and the reaction rate were determined by simultaneously detecting electrons from the neutron decay and protons from the $^3$He(n,p)$^3$H reaction using a gas chamber of which working gas contains diluted $^3$He. The measured neutron lifetime was $898\,\pm\,10\,_{\rm stat}\,^{+15}_{-18}\,_{\rm sys}\,$s.

hep-ex

Improved determination of thermal cross section of 14N(n,p)14C for the neutron lifetime measurement

In a neutron lifetime measurement at the Japan Proton Accelerator Complex, the neutron lifetime is calculated by the neutron decay rate and the incident neutron flux. The flux is obtained due to counting the protons emitted from the neutron absorption reaction of ${}^{3}{\rm He}$ gas, which is diluted in a mixture of working gas in a detector. Hence, it is crucial to determine the amount of ${}^{3}{\rm He}$ in the mixture. In order to improve the accuracy of the number density of the ${}^{3}{\rm He}$ nuclei, we suggested to use the ${}^{14}{\rm N}({\rm n},{\rm p}){}^{14}{\rm C}$ reaction as a reference because this reaction involves similar kinetic energy as the ${}^{3}{\rm He}({\rm n},{\rm p}){}^{3}{\rm H}$ reaction and a smaller reaction cross section to introduce reasonable large partial pressure. The uncertainty of the recommended value of the cross section, however, is not satisfied with our requirement. In this paper, we report the most accurate experimental value of the cross section of the ${}^{14}{\rm N}({\rm n},{\rm p}){}^{14}{\rm C}$ reaction at a neutron velocity of 2200 m/s, measured relative to the ${}^{3}{\rm He}({\rm n},{\rm p}){}^{3}{\rm H}$ reaction. The result was 1.868 $\pm$ 0.003 (stat.) $\pm$ 0.006 (sys.) b. Additionally, the cross section of the ${}^{17}{\rm O}({\rm n},{\rm α}){}^{14}{\rm C}$ reaction at the neutron velocity is also redetermined as 249 $\pm$ 6 mb.

nucl-ex

Development of time projection chamber for precise neutron lifetime measurement using pulsed cold neutron beams

A new time projection chamber (TPC) was developed for neutron lifetime measurement using a pulsed cold neutron spallation source at the Japan Proton Accelerator Research Complex (J-PARC). Managing considerable background events from natural sources and the beam radioactivity is a challenging aspect of this measurement. To overcome this problem, the developed TPC has unprecedented features such as the use of polyether-ether-ketone plates in the support structure and internal surfaces covered with $^6$Li-enriched tiles to absorb outlier neutrons. In this paper, the design and performance of the new TPC are reported in detail.

physics.ins-det