Searcharxiv⌕ Search

arXiv subjects

H. Tajima

Publications and source records attributed to H. Tajima.

53 records · Page 3Linked to original sources

Gamma-Ray Observations of the Supernova Remnant RX J0852.0-4622 with the Fermi LAT

We report on gamma-ray observations of the supernova remnant (SNR) RX J0852.0-4622 with the Large Area Telescope (LAT) aboard the Fermi Gamma-ray Space Telescope. In the Fermi LAT data, we find a spatially extended source at the location of the SNR. The extension is consistent with the SNR size seen in other wavelengths such as X-rays and TeV gamma rays, leading to the identification of the gamma-ray source with the SNR. The spectrum is well described as a power law with a photon index of Gamma = 1.85 +/- 0.06 (stat) (+0.18,-0.19) (sys), which smoothly connects to the H.E.S.S. spectrum in the TeV energy band. We discuss the gamma-ray emission mechanism based on multiwavelength data. The broadband data can be fit well by a model in which the gamma rays are of hadronic origin. We also consider a scenario with inverse Compton scattering of electrons as the emission mechanism of the gamma rays. Although the leptonic model predicts a harder spectrum in the Fermi LAT energy range, the model can fit the data considering the statistical and systematic errors.

astro-ph.HE↗

DUAL Gamma-Ray Mission

Gamma-ray astronomy presents an extraordinary scientific potential for the study of the most powerful sources and the most violent events in the Universe. In order to take full advantage of this potential, the next generation of instrumentation for this domain will have to achieve an improvement in sensitivity over present technologies of at least an order of magnitude. The DUAL mission concept takes up this challenge in two complementary ways: a very long observation of the entire sky, combined with a large collection area for simultaneous observations of Type Ia SNe. While the Wide-Field Compton Telescope (WCT) accumulates data from the full gamma-ray sky (0.1-10 MeV) over the entire mission lifetime, the Laue-Lens Telescope (LLT) focuses on 56Co emission from SNe Ia (0.8-0.9 MeV), collecting gamma-rays from its large area crystal lens onto the WCT. Two separated spacecraft flying in formation will maintain the DUAL payloads at the lens' focal distance.

astro-ph.IM↗

The NeXT Mission

The NeXT (New exploration X-ray Telescope), the new Japanese X-ray Astronomy Satellite following Suzaku, is an international X-ray mission which is currently planed for launch in 2013. NeXT is a combination of wide band X-ray spectroscopy (3 - 80 keV) provided by multi-layer coating, focusing hard X-ray mirrors and hard X-ray imaging detectors, and high energy-resolution soft X-ray spectroscopy (0.3 - 10 keV) provided by thin-foil X-ray optics and a micro-calorimeter array. The mission will also carry an X-ray CCD camera as a focal plane detector for a soft X-ray telescope and a non-focusing soft gamma-ray detector. With these instruments, NeXT covers very wide energy range from 0.3 keV to 600 keV. The micro-calorimeter system will be developed by international collaboration lead by ISAS/JAXA and NASA. The simultaneous broad bandpass, coupled with high spectral resolution of Delta E ~ 7 eV by the micro-calorimeter will enable a wide variety of important science themes to be pursued.

astro-ph↗

Status of GRB Observations with the Suzaku Wideband All-sky Monitor

The Wide-band All-sky Monitor (WAM) is a function of the large lateral BGO shield of the Hard X-ray Detector (HXD) onboard Suzaku. Its large geometrical area of 800 cm^2 per side, the large stopping power for the hard X-rays and the wide-field of view make the WAM an ideal detector for gamma-ray bursts (GRBs) observations in the energy range of 50-5000 keV. In fact, the WAM has observed 288 GRBs confirmed by other satellites, till the end of May 2007.

astro-ph↗

Measuring energy dependent polarization in soft gamma-rays using Compton scattering in PoGOLite

Linear polarization in X- and gamma-rays is an important diagnostic of many astrophysical sources, foremost giving information about their geometry, magnetic fields, and radiation mechanisms. However, very few X-ray polarization measurements have been made, and then only mono-energetic detections, whilst several objects are assumed to have energy dependent polarization signatures. In this paper we investigate whether detection of energy dependent polarization from cosmic sources is possible using the Compton technique, in particular with the proposed PoGOLite balloon-experiment, in the 25-100 keV range. We use Geant4 simulations of a PoGOLite model and input photon spectra based on Cygnus X-1 and accreting magnetic pulsars (100 mCrab). Effective observing times of 6 and 35 hours were simulated, corresponding to a standard and a long duration flight respectively. Both smooth and sharp energy variations of the polarization are investigated and compared to constant polarization signals using chi-square statistics. We can reject constant polarization, with energy, for the Cygnus X-1 spectrum (in the hard state), if the reflected component is assumed to be completely polarized, whereas the distinction cannot be made for weaker polarization. For the accreting pulsar, constant polarization can be rejected in the case of polarization in a narrow energy band with at least 50% polarization, and similarly for a negative step distribution from 30% to 0% polarization.

astro-ph↗

Design and Performance of the Soft Gamma-ray Detector for the NeXT mission

The Soft Gamma-ray Detector (SGD) on board the NeXT (Japanese future high energy astrophysics mission) is a Compton telescope with narrow field of view (FOV), which utilizes Compton kinematics to enhance its background rejection capabilities. It is realized as a hybrid semiconductor gamma-ray detector which consists of silicon and CdTe (cadmium telluride) detectors. It can detect photons in a wide energy band (0.05-1 MeV) at a background level of 5 x 10^-7 counts/cm^2/s; the silicon layers are required to improve the performance at a lower energy band (<0.3 MeV). Excellent energy resolution is the key feature of the SGD, allowing it to achieve both high angular resolution and good background rejection capability. An additional capability of the SGD, its ability to measure gamma-ray polarization, opens up a new window to study properties of astronomical objects. We will present the development of key technologies to realize the SGD: high quality CdTe, low noise front-end ASIC and bump bonding technology. Energy resolutions of 1.7 keV (FWHM) for CdTe pixel detectors and 1.1 keV for Si strip detectors have been measured. We also present the validation of Monte Carlo simulation used to evaluate the performance of the SGD.

astro-ph↗

Beam Test of a Prototype Detector Array for the PoGO Astronomical Hard X-Ray/Soft Gamma-Ray Polarimeter

Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after modifications to its implementation of polarized Compton/Rayleigh scattering. Details of the beam test and the validation of the Geant4 simulations are presented.

astro-ph↗

Wide band X-ray Imager (WXI) and Soft Gamma-ray Detector (SGD) for the NeXT Mission

The NeXT mission has been proposed to study high-energy non-thermal phenomena in the universe. The high-energy response of the super mirror will enable us to perform the first sensitive imaging observations up to 80 keV. The focal plane detector, which combines a fully depleted X-ray CCD and a pixellated CdTe detector, will provide spectra and images in the wide energy range from 0.5 keV to 80 keV. In the soft gamma-ray band up to ~1 MeV, a narrow field-of-view Compton gamma-ray telescope utilizing several tens of layers of thin Si or CdTe detector will provide precise spectra with much higher sensitivity than present instruments. The continuum sensitivity will reach several times 10^(-8) photons/s/keV/cm^(2) in the hard X-ray region and a few times10^(-7) photons/s/keV/cm^(2) in the soft gamma-ray region.

astro-ph↗

Performance of a Low Noise Front-end ASIC for Si/CdTe Detectors in Compton Gamma-ray Telescope

Compton telescopes based on semiconductor technologies are being developed to explore the gamma-ray universe in an energy band 0.1--20 MeV, which is not well covered by the present or near-future gamma-ray telescopes. The key feature of such Compton telescopes is the high energy resolution that is crucial for high angular resolution and high background rejection capability. The energy resolution around 1 keV is required to approach physical limit of the angular resolution due to Doppler broadening. We have developed a low noise front-end ASIC (Application-Specific Integrated Circuit), VA32TA, to realize this goal for the readout of Double-sided Silicon Strip Detector (DSSD) and Cadmium Telluride (CdTe) pixel detector which are essential elements of the semiconductor Compton telescope. We report on the design and test results of the VA32TA. We have reached an energy resolution of 1.3 keV (FWHM) for 60 keV and 122 keV at 0 degree C with a DSSD and 1.7 keV (FWHM) with a CdTe detector.

astro-ph↗

Electronic correlation in the infrared optical properties of the quasi two dimensional $κ$-type BEDT-TTF dimer system

The polarized optical reflectance spectra of the quasi two dimensional organic correlated electron system $κ$-(BEDT-TTF)$_{2}$Cu[N(CN)$_{2}$]$Y$, $Y =$ Br and Cl are measured in the infrared region. The former shows the superconductivity at $T_{\rm c} \simeq$ 11.6 K and the latter does the antiferromagnetic insulator transition at $T_{\rm N} \simeq$ 28 K. Both the specific molecular vibration mode $ν_{3}(a_{g})$ of the BEDT-TTF molecule and the optical conductivity hump in the mid-infrared region change correlatively at $T^{*} \simeq$ 38 K of $κ$-(BEDT-TTF)$_{2}$Cu[N(CN)$_{2}$]Br, although no indication of $T^{*}$ but the insulating behaviour below $T_{\rm ins} \simeq$ 50-60 K are found in $κ$-(BEDT-TTF)$_{2}$Cu[N(CN)$_{2}$]Cl. The results suggest that the electron-molecular vibration coupling on the $ν_{3}(a_{g})$ mode becomes weak due to the enhancement of the itinerant nature of the carriers on the dimer of the BEDT-TTF molecules below $T^{*}$, while it does strong below $T_{\rm ins}$ because of the localized carriers on the dimer. These changes are in agreement with the reduction and the enhancement of the mid-infrared conductivity hump below $T^{*}$ and $T_{\rm ins}$, respectively, which originates from the transitions between the upper and lower Mott-Hubbard bands. The present observations demonstrate that two different metallic states of $κ$-(BEDT-TTF)$_{2}$Cu[N(CN)$_{2}$]Br are regarded as {\it a correlated good metal} below $T^{*}$ including the superconducting state and {\it a half filling bad metal} above $T^{*}$. In contrast the insulating state of $κ$-(BEDT-TTF)$_{2}$Cu[N(CN)$_{2}$]Cl below $T_{\rm ins}$ is the Mott insulator.

cond-mat.supr-con↗

Low Noise Double-Sided Silicon Strip Detector for Multiple-Compton Gamma-ray Telescope

A Semiconductor Multiple-Compton Telescope (SMCT) is being developed to explore the gamma-ray universe in an energy band 0.1--20 MeV, which is not well covered by the present or near-future gamma-ray telescopes. The key feature of the SMCT is the high energy resolution that is crucial for high angular resolution and high background rejection capability. We have developed prototype modules for a low noise Double-sided Silicon Strip Detector (DSSD) system which is an essential element of the SMCT. The geometry of the DSSD is optimized to achieve the lowest noise possible. A new front-end VLSI device optimized for low noise operation is also developed. We report on the design and test results of the prototype system. We have reached an energy resolution of 1.3 keV (FWHM) for 60 keV and 122 keV at 0 degree C.

astro-ph↗

B CP-Violation, Mixing and Lifetime Results from Belle

Recent results on the $B$ CP-violation parameter $\sin2ϕ_1$, the $B^0_d$-$\overline{B}^0_d$ mixing parameter $Δm_d$ and $B$-meson lifetimes are reported. The results are based on 10.5 $fb^{-1}$ of data collected with the Belle detector at KEKB. Using both semileptonic and hadronic decay modes the neutral and charged $B$-meson lifetimes are measured to be $\taubz=1.548\pm0.035 (\mathrm{stat.})$~ps and $\taubm=1.656\pm0.038 (\mathrm{stat.})$~ps. The oscillation frequency $Δm_d$ for $B^0_d$-$\overline{B}^0_d$ mixing is measured to be $0.522\pm0.026 (\mathrm{stat.})$~ps$^{-1}$ using semileptonic modes and $0.527\pm0.032 (\mathrm{stat.})$~ps$^{-1}$ using hadronic modes. The above results are preliminary. The time evolution of $B^0_d$ decays into $J/ψK^0_S$, $ψ(2S) K^0_S$, $χ_{c1} K^0_S$, $η_{c} K^0_S$, $J/ψK^0_L$ and $J/ψπ^0$ modes are studied to obtain $\sin2ϕ_1$. Using 282 fully reconstructed events, $\sin2ϕ_1$ is measured to be $$\sin 2ϕ_1=0.58^{+0.32}_{-0.34} (\mathrm{stat.})^{+0.09}_{-0.10} (\mathrm{syst.} ).$$

hep-ex↗

Studies of 100 um-thick silicon strip detector with analog VLSI readout

We evaluate the performances of a 100 um-thick silicon strip detector (SSD) with a 300 MeV proton beam and a 90Sr beta-ray source. Signals from the SSD have been read out using a VLSI chip. Common-mode noise, signal separation efficiency and energy resolution are compared with those for the SSD's with a thickness of 300 um and 500 um. Energy resolution for minimum ionizing particles (MIP's) is improved by fitting the non-constant component in a common-mode noise with a linear function.

physics.ins-det↗

Molecular conductors with two-chain orbitals

We investigate a theoretical model applicable to molecular conductors, such as TTP and $M(dmit)_2$ salts [M=Ni, Pd, Pt], whose charge carriers orig inate from two kinds of molecular orbitals. The model Hamiltonian consists of two independent Hubbard chains. The degree of charge transfer between the two chains is calculated. The results qualitatively agree with some experimental data.

cond-mat↗

Measurement of B(D_s+ -> mu+ nu_mu)/B(D_s+ -> phi mu+ nu_mu) and Determination of the Decay Constant f_{D_s}

We have observed $23.2 \pm 6.0_{-0.9}^{+1.0}$ purely-leptonic decays of $D_s^+ -> μ^+ ν_μ$ from a sample of muonic one prong decay events detected in the emulsion target of Fermilab experiment E653. Using the $D_s^+ -> ϕμ^+ ν_μ$ yield measured previously in this experiment, we obtain $B(D_s^+ --> μ^+ ν_μ) / B(D_s^+ --> ϕμ^+ ν_μ) =0.16 \pm 0.06 \pm 0.03$. In addition, we extract the decay constant $f_{D_s}=194 \pm 35 \pm 20 \pm 14 MeV$.

hep-ex↗