SearcharxivSearch

arXiv subjects

H. Triou

Publications and source records attributed to H. Triou.

4 recordsLinked to original sources

ECLAIRs: the SVOM high-energy transient trigger camera

The core instrument of the SVOM Gamma-ray burst mission launched in June 2024 is the 4-150 keV 2-D coded mask camera ECLAIRs responsible for the autonomous trigger and localization of transient events within its field of view. The flight model of ECLAIRs has been built by several French labs (IRAP, CEA, APC) under the supervision of the French Space Agency (CNES), while APC, LUPM and IAP built a suite of data reduction and analysis software. This paper outlines the main science goals of ECLAIRs and describes the different instrument sub-systems and their main characteristics. The paper then discusses the instrument configuration and operation as well as the main in-flight measured performances. Finally, the paper summarizes the science performance of ECLAIRs up to March 31, 2025.

astro-ph.HE

Designing large pixelated CdTe detection planes for hard X-ray transients detection

We discuss the need for very large detection planes for the detection of hard X-ray transients in the multi-messenger era that started with the quasi-simultaneous detection of GRB~170817A by \textit{Fermi}/GBM and \textit{INTEGRAL}/SPI on one hand and the gravitational waves event GW 170817, detected by the LVC collaboration, on the other hand. Then, we present a brief survey of current and future instruments and their expected sensitivity, pointing the fact that the gain in the number of GRBs is achieved by future projects thanks to their larger field of view rather than to their larger effective area. Based on our experience with \textit{SVOM}/ECLAIRs, we then address various problems associated with the realization of very large detection planes (\mbox{$\ge 1 \mathrm m^{2}$}), and we demonstrate that CdTe detectors are well suited for this task. We conclude with a discussion of some key parameters that must be taken into account in the realization of instruments based on these detectors. We hope that this paper will motivate the elaboration of detailed proposals of large area wide-field hard X-ray monitors that will be crucially needed in the next decade.

astro-ph.IM

The X-/Gamma-ray camera ECLAIRs for the Gammay-ray burst mission SVOM

We present ECLAIRs, the Gamma-ray burst (GRB) trigger camera to fly on-board the Chinese-French mission SVOM. ECLAIRs is a wide-field ($\sim 2$\,sr) coded mask camera with a mask transparency of 40\% and a 1024 $\mathrm{cm}^2$ detection plane coupled to a data processing unit, so-called UGTS, which is in charge of locating GRBs in near real time thanks to image and rate triggers. We present the instrument science requirements and how the design of ECLAIRs has been optimized to increase its sensitivity to high-redshift GRBs and low-luminosity GRBs in the local Universe, by having a low-energy threshold of 4 keV. The total spectral coverage ranges from 4 to 150 keV. ECLAIRs is expected to detect $\sim 200$ GRBs of all types during the nominal 3 year mission lifetime. To reach a 4 keV low-energy threshold, the ECLAIRs detection plane is paved with 6400 $4\times 4~\mathrm{mm}^2$ and 1 mm-thick Schottky CdTe detectors. The detectors are grouped by 32, in 8x4 matrices read by a low-noise ASIC, forming elementary modules called XRDPIX. In this paper, we also present our current efforts to investigate the performance of these modules with their front-end electronics when illuminated by charged particles and/or photons using radioactive sources. All measurements are made in different instrument configurations in vacuum and with a nominal in-flight detector temperature of $-20^\circ$C. This work will enable us to choose the in-flight configuration that will make the best compromise between the science performance and the in-flight operability of ECLAIRs. We will show some highlights of this work.

physics.ins-det

In-flight calibration of the Herschel-SPIRE instrument

SPIRE, the Spectral and Photometric Imaging Receiver, is the Herschel Space Observatory's submillimetre camera and spectrometer. It contains a three-band imaging photometer operating at 250, 350 and 500 μm, and an imaging Fourier transform spectrometer (FTS) covering 194-671 μm (447-1550 GHz). In this paper we describe the initial approach taken to the absolute calibration of the SPIRE instrument using a combination of the emission from the Herschel telescope itself and the modelled continuum emission from solar system objects and other astronomical targets. We present the photometric, spectroscopic and spatial accuracy that is obtainable in data processed through the "standard" pipelines. The overall photometric accuracy at this stage of the mission is estimated as 15% for the photometer and between 15 and 50% for the spectrometer. However, there remain issues with the photometric accuracy of the spectra of low flux sources in the longest wavelength part of the SPIRE spectrometer band. The spectrometer wavelength accuracy is determined to be better than 1/10th of the line FWHM. The astrometric accuracy in SPIRE maps is found to be 2 arcsec when the latest calibration data are used. The photometric calibration of the SPIRE instrument is currently determined by a combination of uncertainties in the model spectra of the astronomical standards and the data processing methods employed for map and spectrum calibration. Improvements in processing techniques and a better understanding of the instrument performance will lead to the final calibration accuracy of SPIRE being determined only by uncertainties in the models of astronomical standards.

astro-ph.IM