Searcharxiv⌕ Search

arXiv subjects

H. Van Swygenhoven

Publications and source records attributed to H. Van Swygenhoven.

3 recordsLinked to original sources

Evaluation of two thermal neutron detection units consisting of ZnS/${}^6$LiF scintillating layers with embedded WLS fibers read out with a SiPM

Two single channel detection units for thermal neutron detection are investigated in a neutron beam. They consist of two ZnS/${}^6$LiF scintillating layers sandwiching an array of WLS fibers. The pattern of this units can be repeated laterally and vertically in order to build up a one dimensional position sensitive multi-channel detector with the needed sensitive surface and with the required neutron absorption probability. The originality of this work arises from the fact that the WLS fibers are read out with SiPMs instead of the traditionally used PMTs or MaPMTs. The signal processing system is based on a photon counting approach. For SiPMs with a dark count rate as high as 0.7 MHz, a trigger efficiency of 80% is achieved together with a system background rate lower than ${10}^{-3}$ Hz and a dead time of 30 $μ$s. No change of performance is observed for neutron count rates of up to 3.6 kHz.

physics.ins-det↗

Upgrade of the POLDI diffractometer with a ZnS(Ag)/6LiF scintillation detector read out with WLS fibers coupled to SiPMs

A thermal neutron detector based on ZnS(Ag)/6LiF scintillator, wavelength-shifting fibers (WLS) and silicon photomultipliers (SiPM) is under development at the Paul Scherrer Institute (PSI) for upgrading the POLDI instrument, a pulse-overlap diffractometer. The design of the detector is outlined, and the measurements performed on a single channel prototype are presented. An innovative signal processing system based on a photon counting approach is under development. Its principle of operation is described and its performances are evaluated on the basis of a Monte Carlo simulation.

physics.ins-det↗

The bandstructure of gold from many-body perturbation theory

The bandstructure of gold is calculated using many-body perturbation theory (MBPT). Different approximations within the GW approach are considered. Standard single shot G0W0 corrections shift the unoccupied bands up by ~0.2 eV and the first sp-like occupied band down by ~0.4 eV, while leaving unchanged the 5d occupied bands. Beyond G0W0, quasiparticle self-consistency on the wavefunctions lowers the occupied 5d bands by 0.35 eV. Globally, many-body effects achieve an opening of the interband gap (5d-6sp gap) of 0.35 to 0.75 eV approaching the experimental results. Finally, the quasiparticle bandstructure is compared to the one obtained by the widely used HSE (Heyd, Scuseria, and Ernzerhof) hybrid functional.

cond-mat.mtrl-sci↗