SearcharxivSearch

arXiv subjects

H. Wollnik

Publications and source records attributed to H. Wollnik.

At least 19 recordsLinked to original sources

High-Precision Mass Measurements of Proton-Rich Rh, Pd, Cd isotopes in the vicinity of 100Sn and Impact on X-Ray Burst and Supernova Nucleosynthesis

Using the ZeroDegree multi-reflection time-of-flight mass spectrograph of the CRISMASS project at RIKEN Radioactive Isotope Beam Factory, we performed high-precision mass measurements of proton-rich nuclei near the doubly magic nucleus 100Sn, achieving uncertainties on the order of 10 keV. The masses of 91Rh, 92Pd, and 96Cd were determined for the first time with high precision, and the accuracy of several additional masses was substantially improved. Incorporating the new data into X-ray burst simulations significantly reduces the abundance uncertainties in the $A$ = 90-100 region, shifting the reaction flow toward $A$ = 90 production and suppressing the synthesis of heavier nuclei. Further investigation of the $\nu p$-process indicates that 99Rh plays a significant role in the reaction flow within the mass region studied. These high-precision mass measurements refine the mass surface near 100Sn and provide critical constraints on models of proton-rich nucleosynthesis.

nucl-ex

A new study of the $N=32$ and $N=34$ shell gap for Ti and V by the first high-precision MRTOF mass measurements at BigRIPS-SLOWRI

The atomic masses of $^{55}$Sc, $^{56,58}$Ti, and $^{56-59}$V have been determined using the high-precision multi-reflection time-of-flight technique. The radioisotopes have been produced at RIKEN's RIBF facility and delivered to the novel designed gas cell and multi-reflection system (ZD MRTOF), which has been recently commissioned downstream of the ZeroDegree spectrometer following the BigRIPS separator. For $^{56,58}$Ti and $^{56-59}$V the mass uncertainties have been reduced down to the order of $10\,\mathrm{keV}$, shedding new light on the $N=34$ shell effect in Ti and V isotopes by the first high-precision mass measurements of the critical species $^{58}$Ti and $^{59}$V. With the new precision achieved, we reveal the non-existence of the $N=34$ empirical two-neutron shell gaps for Ti and V, and the enhanced energy gap above the occupied $νp_{3/2}$ orbit is identified as a feature unique to Ca. We perform new Monte Carlo shell model calculations including the $νd_{5/2}$ and $νg_{9/2}$ orbits and compare the results with conventional shell model calculations, which exclude the $νg_{9/2}$ and the $νd_{5/2}$ orbits. The comparison indicates that the shell gap reduction in Ti is related to a partial occupation of the higher orbitals for the outer two valence neutrons at $N=34$.

nucl-ex

The new MRTOF mass spectrograph following the ZeroDegree spectrometer at RIKEN's RIBF facility

A newly assembled multi-reflection time-of-flight mass spectrograph (MRTOF-MS) at RIKEN's RIBF facility became operational for the first time in spring 2020; further modifications and performance tests using stable ions were completed in early 2021. By using a pulsed-drift-tube technique to modify the ions' kinetic energy in a wide range, we directly characterize the dispersion function of the system for use in a new procedure for optimizing the voltages applied to the electrostatic mirrors. Thus far, a mass resolving power of $R_m > 1\,000\,000$ is reached within a total time-of-flight of only $12.5\,\mathrm{ms}$, making the spectrometer capable of studying short-lived nuclei possessing low-lying isomers. Detailed information about the setup and measurement procedure is reported, and an alternative in-MRTOF ion selection scheme to remove molecular contaminants in the absence of a dedicated deflection device is introduced. The setup underwent an initial on-line commissioning at the BigRIPS facility at the end of 2020, where more than 70 nuclear masses have been measured. A summary of the commissioning experiments and results from a test of mass accuracy will be presented.

physics.ins-det

Alpha-decay-correlated mass measurement of 206,207Ra using an $α$-TOF detector equipped MRTOF-MS system

The atomic masses of the isotopes $^{206,207}$Ra have been measured via decay-correlated mass spectroscopy using a multi-reflection time-of-flight mass spectrograph equipped with an $α$-TOF detector. The Ra isotopes were produced as fusion-evaporation products in the $^{51}$V+$^{159}$Tb reaction system and delivered by the gas-filled recoil ion separator GARIS-II at RIKEN. The $α$-TOF detector provides for high-accuracy mass measurements by correlating time-of-flight signals with subsequent $α$-decay events. The masses of $^{206}$Ra and $^{207g,m}$Ra were directly measured using a multi-reflection time-of-flight mass spectrograph equipped with an $α$-TOF detector. A mass excess of ME = 3538(15) keV/c$^2$ and an excitation energy of E$_{\rm ex}$ = 552(42) keV were determined. The $α$-decay branching ratio of $^{207m}$Ra, b$α$ = 0.26(20), was directly determined from decay-correlated time-of-flight signals, and the reduced alpha width of $^{207m}$Ra was calculated to be $δ^2$ = 50+62-41 keV from the branching ratio. The spin-parity of $^{207m}$Ra was confirmed to be $J^π$ = 13/2$^-$ from decay correlated mass measurement results.

nucl-ex

First high-precision direct determination of the atomic mass of a superheavy nuclide

We present the first direct measurement of the atomic mass of a superheavy nuclide. Atoms of $^{257}$Db ($Z$=105) were produced online at the RIKEN Nishina Center for Accelerator-Based Science using the fusion-evaporation reaction $^{208}$Pb($^{51}$V, 2n)$^{257}$Db. The gas-filled recoil ion separator GARIS-II was used to suppress both the unreacted primary beam and some transfer products, prior to delivering the energetic beam of $^{257}$Db ions to a helium gas-filled ion stopping cell wherein they were thermalized. Thermalized $^{257}$Db$^{3+}$ ions were then transferred to a multi-reflection time-of-flight mass spectrograph for mass analysis. An alpha particle detector embedded in the ion time-of-flight detector allowed disambiguation of the rare $^{257}$Db$^{3+}$ time-of-flight detection events from background by means of correlation with characteristic $α$-decays. The extreme sensitivity of this technique allowed a precision atomic mass determination from 11 events. The mass excess was determined to be $100\,063(231)_\textrm{stat}(132)_\textrm{sys}$~keV/c$^2$. Comparing to several mass models, we show the technique can be used to unambiguously determine the atomic number as $Z$=105 and should allow similar evaluations for heavier species in future work.

nucl-ex

Accurately accounting for effects on times-of-flight caused by finite field-transition times during the ejection of ions from a storage trap: A study for TOF and MRTOF mass spectrometry

In applied forms of time-of-flight mass spectrometry utilizing ion storage devices prior to an analysis device, a non instantaneous electric ejection pulse applied in the region of ion storage is used to accelerate ions into the time-of-flight analyzer. The calculated mass value of the ions from the time-of-flight is dependent on the duration of the field transition up to full strength. For novel applications dedicated to precision measurements, such as multi-reflection time-of-flight mass spectrometry of short-lived isotopes, the goal is to continuously decrease the measurement uncertainty while providing a mass accuracy on the same order. Even though dynamic-field models for time-of-flight mass spectrometry have been considered in the past for technological advances, it is important to study the accuracy of the measured mass in this context. Using a simplified linear model for the field transition, we provide a basic investigation of the scenario, and discuss the deviation from the classical "mass-over-charge" dependency of the ions' time-of-flight, which becomes violated. The emerging mass discrepancy depends on the distance between the mass of the ion used for calibration and that of the ion of interest and, in extreme cases, can increase to about one percent for systems with short times-of-flight. However, for typical conditions in single-reference multi-reflection time-of-flight mass spectrometry, mass deviations caused by this effect typically remain below the 1 ppm level. If a mass calibration using two or more ion species is possible during the measurement, the effect becomes negligible for appropriate choices of reference masses.

physics.ins-det

Development of an "$α$-ToF" detector for correlated measurement of atomic masses and decay properties

We have developed a novel detector, referred to as an "$α$-ToF detector", for correlated measurements of atomic masses and decay properties of low-yield, short-lived radioactive isotopes using a multi-reflection time-of-flight mass spectrograph. By correlating measured time-of-flight signals with decay events, it will be possible to suppress background events and obtain accurate, high-precision mass values even in cases of very low event rates. An offline test of the $α$-ToF detector has shown that the time-of-flight detection efficiency for 5.48~MeV $α$-rays is more than 90\% and yields a time resolution of 251.5(68)~ps and an energy resolution of 141.1(9)~keV. Using a two-dimensional spectrum of the correlated $α$-ray energy and time-of-flight, the $α$-rays from mixed $α$ sources could be fairly well resolved.

physics.ins-det

New mass anchor points for neutron-deficient heavy nuclei from direct mass measurements of radium and actinium isotopes

The masses of the exotic isotopes $^{210-214}$Ac and $^{210-214}$Ra have been measured with a multi-reflection time-of-flight mass spectrograph. These isotopes were obtained in flight as fusion-evaporation products behind the gas-filled recoil ion separator GARIS-II at RIKEN. The new direct mass measurements serve as an independent and direct benchmark for existing $α$-$γ$ spectroscopy data in this mass region. Further, new mass anchor points are set for U and Np nuclei close to the $N=126$ shell closure for a future benchmark of the $Z=92$ sub-shell for neutron-deficient heavy isotopes. Our mass results are in general in good agreement with the previously indirectly-determined mass values. Together with the measurement data, reasons for possible mass ambiguities from decay-data links between ground states are discussed.

nucl-ex

Improving wide-band mass measurements in a multi-reflection time-of-flight mass spectrograph by usage of a concomitant measurement scheme

We introduce a new concomitant referencing mode for operating a multi-reflection time-of-flight mass spectrograph (MRTOF-MS), wherein the reference and analyte ions are interleaved on a cycle by cycle bases. Using this mode, we demonstrate an improved technique for performing wide bandwidth mass measurements via MRTOF-MS. This new technique offers a simplified analysis and high-accuracy.

physics.ins-det

First direct mass measurements of nuclides around $Z=100$ with a Multireflection Time-of-Flight Mass Spectrograph

The masses of $^{246}$Es, $^{251}$Fm and the transfermium nuclei $^{249-252}$Md, and $^{254}$No, produced by hot- and cold-fusion reactions, in the vicinity of the deformed $N=152$ neutron shell closure, have been directly measured using a multireflection time-of-flight mass spectrograph. The masses of $^{246}$Es and $^{249,250,252}$Md were measured for the first time. Using the masses of $^{249,250}$Md as anchor points for $α$ decay chains, the masses of heavier nuclei, up to $^{261}$Bh and $^{266}$Mt, were determined. These new masses were compared with theoretical global mass models and demonstrated to be in good agreement with macroscopic-microscopic models in this region. The empirical shell gap parameter $δ_{2n}$ derived from three isotopic masses was updated with the new masses and corroborate the existence of the deformed $N=152$ neutron shell closure for Md and Lr.

nucl-ex

Atomic masses of intermediate-mass neutron-deficient nuclei with relative uncertainty down to 35-ppb via multireflection time-of-flight mass spectrograph

High-precision mass measurements of $^{63}$Cu, $^{64-66}$Zn, $^{65}$Ga, $^{65-67}$Ge, $^{67}$As, $^{78,81}$Br, $^{80}$Rb, and $^{79}$Sr were performed utilizing a multireflection time-of-flight mass spectrograph combined with the gas-filled recoil ion separator GARIS-II. In the case of $^{65}$Ga, a mass uncertainty of 2.1 keV, corresponding to a relative precision of $δm / m = 3.5\times10^{-8}$, was obtained and the mass value is in excellent agreement with the 2016 Atomic Mass Evaluation. For $^{67}$Ge and $^{81}$Br, where masses were previously deduced through indirect measurements, discrepancies with literature values were found. The feasibility of using this device for mass measurements of nuclides more neutron-deficient side, which have significant impact on the $rp$-process pathway, is discussed.

nucl-ex

First Online Mass Measurements of Isobar Chains via Multi-Reflection Time-of-Flight Mass Spectrograph Coupled with GARIS-II

Using a mulit-reflection time-of-flight mass spectrograph (MRTOF-MS) located after a gas cell coupled with the gas-filled recoil ion separator GARIS-II, the masses of several heavy nuclei have been directly and precisely measured. The nuclei were produced via fusion-evaporation reactions and separated from projectile-like and target-like particles using GARIS-II before being stopped in a helium-filled gas cell. Time-of-flight spectra for three isobar chains, 205Fr-205Rn-205At-205Po, 206Fr-206Rn-206At and 201Rn-201At-201Po-201Bi, were observed. Precision atomic mass values were determined for 205,206Fr, 201At, and 201Po.

nucl-ex

A novel ion cooling trap for multi-reflection time-of-flight mass spectrograph

A radiofrequency quadrupole ion trap system for use with a multi-reflection time-of-flight mass spectrograph (MRTOF) for short-lived nuclei has been developed. The trap system consists of two different parts, an asymmetric taper trap and a flat trap. The ions are cooled to a sufficient small bunch for precise mass measurement with MRTOF in only 2 ms cooling time in the flat trap, then orthogonally ejected to the MRTOF for mass analysis. A trapping efficiency of ~27% for 23Na+ and ~5.1% for 7Li+ has been achieved.

physics.ins-det

Single-reference high-precision mass measurement with a multi-reflection time-of-flight mass spectrograph

A multi-reflection time-of-flight mass spectrograph, competitive with Penning trap mass spectrometers, has been built at RIKEN. We have performed a first online mass measurement, using 8Li+ (T1/2 = 838 ms). A new analysis method has been realized, with which, using only 12C+ references, the mass excess of 8Li was accurately determined to be 20947.6(15)(34) keV (dm/m = 6.6 x 10-7). The speed, precision and accuracy of this first online measurement exemplifies the potential for using this new type of mass spectrograph for precision measurements of short-lived nuclei.

nucl-ex

An rf-carpet electrospray ion source to provide isobaric mass calibrants for trans-uranium elements

For trans-uranium elements, stable atomic isobars do not exist. In order to provide isobaric reference ions for the mass measurement of trans-uranium elements, an electrospray ion source (ESI) was combined with an rf-carpet to collect molecular ions efficiently. The rf-carpet allows for simplification of the pumping system to transport ions from the ESI to a precision mass analyzer. Molecular ions appropriate for isobaric references of trans-uranium elements were extracted from the rf-carpet and analyzed by a multi-reflection time-of-flight mass spectrograph (MRTOF-MS) with a resolving power of $\rm{R_m} \gtrsim100,000$.

nucl-ex

Isospin Dependence in the Odd-Even Staggering of Nuclear Binding Energies

The FRS-ESR facility at GSI provides unique conditions for precision measurements of large areas on the nuclear mass surface in a single experiment. Values for masses of 604 neutron-deficient nuclides (30<=Z<=92) were obtained with a typical uncertainty of 30 microunits. The masses of 114 nuclides were determined for the first time. The odd-even staggering (OES) of nuclear masses was systematically investigated for isotopic chains between the proton shell closures at Z=50 and Z=82. The results were compared with predictions of modern nuclear models. The comparison revealed that the measured trend of OES is not reproduced by the theories fitted to masses only. The spectral pairing gaps extracted from models adjusted to both masses, and density related observables of nuclei agree better with the experimental data.

nucl-th

The Cosmic Ray Muon Flux at WIPP

In this work a measurement of the muon intensity at the Waste Isolation Pilot Plant (WIPP) near Carlsbad, NM, USA is presented. WIPP is a salt mine with a depth of 655 m. The vertical muon flux was measured with a two panels scintillator coincidence setup to Phi_{vert}=3.10(+0.05/-0.07)*10^(-7)s^(-1)cm^(-2)sr^(-1).

astro-ph