Searcharxiv⌕ Search

arXiv subjects

H. Y. Lee

Publications and source records attributed to H. Y. Lee.

At least 37 records · Page 2Linked to original sources

Three-year annual modulation search with COSINE-100

COSINE-100 is a direct detection dark matter experiment that aims to test DAMA/LIBRA's claim of dark matter discovery by searching for a dark matter-induced annual modulation signal with NaI(Tl) detectors. We present new constraints on the annual modulation signal from a dataset with a 2.82 yr livetime utilizing an active mass of 61.3 kg, for a total exposure of 173 kg$\cdot$yr. This new result features an improved event selection that allows for both lowering the energy threshold to 1 keV and a more precise time-dependent background model. In the 1-6 keV and 2-6 keV energy intervals, we observe best-fit values for the modulation amplitude of 0.0067$\pm$0.0042 and 0.0051$\pm$0.0047 counts/(day$\cdot$kg$\cdot$keV), respectively, with a phase fixed at 152.5 days.

hep-ex↗

An induced annual modulation signature in COSINE-100 data by DAMA/LIBRA's analysis method

The DAMA/LIBRA collaboration has reported the observation of an annual modulation in the event rate that has been attributed to dark matter interactions over the last two decades. However, even though tremendous efforts to detect similar dark matter interactions were pursued, no definitive evidence has been observed to corroborate the DAMA/LIBRA signal. Many studies assuming various dark matter models have attempted to reconcile DAMA/LIBRA's modulation signals and null results from other experiments, however no clear conclusion can be drawn. Apart from the dark matter hypothesis, several studies have examined the possibility that the modulation is induced by variations in their detector's environment or their specific analysis methods. In particular, a recent study presents a possible cause of the annual modulation from an analysis method adopted by the DAMA/LIBRA experiment in which the observed annual modulation could be reproduced by a slowly varying time-dependent background. Here, we study the COSINE-100 data using an analysis method similar to the one adopted by the DAMA/LIBRA experiment and observe a significant annual modulation, although the modulation phase is almost opposite to that of the DAMA/LIBRA data. Assuming the same background composition for COSINE-100 and DAMA/LIBRA, simulated experiments for the DAMA/LIBRA without dark matter signals also provide significant annual modulation with an amplitude similar to DAMA/LIBRA with opposite phase. Even though this observation does not explain the DAMA/LIBRA's results directly, this interesting phenomenon motivates deeper studies of the time-dependent DAMA/LIBRA background data.

hep-ex↗

A feasibility study of extruded plastic scintillator embedding WLS fiber for AMoRE-II muon veto

AMoRE-II is the second phase of the Advanced Molybdenum-based Rare process Experiment aiming to search for the neutrino-less double beta decay of 100Mo isotopes using ~ 200 kg of molybdenum-containing cryogenic detectors. The AMoRE-II needs to keep the background level below 10-5 counts/keV/kg/year with various methods to maximize the sensitivity. One of the methods is to have the experiment be carried out deep underground free from the cosmic ray backgrounds. The AMoRE-II will run at Yemilab with ~ 1,000 m depth. However, even in such a deep underground environment, there are still survived cosmic muons, which can affect the measurement and should be excluded as much as possible. A muon veto detector is necessary to reject muon-induced particles coming to the inner detector where the molybdate cryogenic detectors are located. We have studied the possibility of using an extruded plastic scintillator and wavelength shifting fiber together with SiPM as a muon veto system. We found that the best configuration is two layers of plastic scintillators (PSs, 150 cm x 25 cm x 1.2 cm) with two WLS fibers per groove, which could separate radiogenic gammas well with muon detection efficiency above 99.4% along the length of the PS. Based on the expected flux from a prototype measurement at a 700 m deep underground, we found that the dead time of the muon veto system for AMoRE-II at the Yemilab with a 1 ms veto window is 0.6% of whole muon events.

physics.ins-det↗

Implementation and validation of realistic (n,x) reaction yields in GEANT4 utilizing a detailed evaluated nuclear reaction library below 20 MeV

Neutron-induced reactions with charged particle emission play an important role in a variety of research fields ranging from fundamental nuclear physics and nuclear astrophysics to applications of nuclear technologies to energy production and material science. Recently, the capability to study reactions with radioactive targets has become important to significantly advance research in explosive nucleosynthesis and nuclear applications. To achieve the relevant research goals and study (n,x) reactions over a broad neutron beam energy range, the Low Energy Neutron-induced charged-particle (Z) chamber (LENZ) at Los Alamos Neutron Science Center (LANSCE) was developed along with varied ancillary instrumentation to enable the aforementioned research program. For the (n,x) reactions of interest at low energies, a precise simulation of the discrete spectrum of emitted charged particles is essential. In addition, since LANSCE is a user facility, a simulation application that can be easily accessible by users has high value. With these goals in mind, we have developed a detailed simulation using the GEANT4 toolkit. In this work, we present the implementation and the validation of the simulation using experimental data from recent campaigns with the LENZ instrument. Specifically, we benchmark the simulation against a similar MCNP-based tool and determine the realistic range of applicability for the probability biasing technique used. We describe our implementation of an evaluated library with angular distribution and partial cross-section data, and we perform a validation of the application based on comparisons of simulated spectra with the experimental ones, for a number of targets used in previous experimental campaigns. Last, we discuss the limitations, caveats, and assets of the simulation code and techniques used.

physics.ins-det↗

Searching for low-mass dark matter via Migdal effect in COSINE-100

We report on the search for weakly interacting massive particle (WIMP) dark matter candidates in the galactic halo that interact with sodium and iodine nuclei in the COSINE-100 experiment and produce energetic electrons that accompany recoil nuclei via the the Migdal effect. The WIMP mass sensitivity of previous COSINE-100 searches that relied on the detection of ionization signals produced by target nuclei recoiling from elastic WIMP-nucleus scattering was restricted to WIMP masses above $\sim$5 GeV/$c^2$ by the detectors' 1 keVee energy-electron-equivalent threshold. The search reported here looks for recoil signals enhanced by the Migdal electrons that are ejected during the scattering process. This is particularly effective for the detection of low-mass WIMP scattering from the crystals' sodium nuclei in which a relatively larger fraction of the WIMP's energy is transferred to the nucleus recoil energy and the excitation of its orbital electrons. In this analysis, the low-mass WIMP search window of the COSINE-100 experiment is extended to WIMP mass down to 200 MeV/$c^2$. The low-mass WIMP sensitivity will be further improved by lowering the analysis threshold based on a multivariable analysis technique. We consider the influence of these improvements and recent developments in detector performance to re-evaluate sensitivities for the future COSINE-200 experiment. With a 0.2 keVee analysis threshold and high light-yield NaI(Tl) detectors (22 photoelectrons/keVee), the COSINE-200 experiment can explore low-mass WIMPs down to 20 MeV/$c^2$ and probe previously unexplored regions of parameter space.

hep-ex↗

The environmental monitoring system at the COSINE-100 experiment

The COSINE-100 experiment is designed to test the DAMA experiment which claimed an observation of a dark matter signal from an annual modulation in their residual event rate. To measure the 1 %-level signal amplitude, it is crucial to control and monitor nearly all environmental quantities that might systematically mimic the signal. The environmental monitoring also helps ensure a stable operation of the experiment. Here, we describe the design and performance of the centralized environmental monitoring system for the COSINE-100 experiment.

physics.ins-det↗

Scintillation characteristics of a NaI(Tl) crystal at low-temperature with silicon photomultiplier

Scintillation characteristics of a thallium doped sodium iodide (NaI(Tl)) crystal with a dimension of 0.6 x 0.6 x 2 cm3 are studied by attaching a silicon photomultiplier (SiPM) direct to the crystal over a temperature range from 93 to 300 K. The scintillation light output and decay time are measured by irradiating 59.54 keV gamma-rays from a 241Am source. We observed approximately 20% increase in light yield at 230K compared to that at the room temperature. At this condition, the NaI(Tl) crystal coupled with the SiPM can be a good candidate for future dark matter search detector.

physics.ins-det↗

Strong constraints from COSINE-100 on the DAMA dark matter results using the same sodium iodide target

We present new constraints on dark matter interactions using 1.7 years of COSINE-100 data. The COSINE-100 experiment, consisting of 106 kg of tallium-doped sodium iodide (NaI(Tl)) target material, is aimed at testing DAMA's claim of dark matter observation using the same NaI(Tl) detectors. Improved event selection requirements, a more precise understanding of the detector background and the use of a larger data set considerably enhances the COSINE-100 sensitivity for dark matter detection. No signal consistent with the dark matter interaction is identified, and rules out model-dependent dark matter interpretations of the DAMA signals in the specific context of standard halo model with the same NaI(Tl) target for various interaction hypotheses.

hep-ex↗

Identification of new isomers in $^{228}$Ac : Impact on dark matter searches

We report the identification of metastable isomeric states of $^{228}$Ac at 6.28 keV, 6.67 keV and 20.19 keV, with lifetimes of an order of 100 ns. These states are produced by the $β$-decay of $^{228}$Ra, a component of the $^{232}$Th decay chain, with $β$ Q-values of 39.52 keV, 39.13 keV and 25.61 keV, respectively. Due to its low Q-value as well as the relative abundance of $^{232}$Th and their progeny in low background experiments, these observations potentially impact the low-energy background modeling of dark matter search experiments.

hep-ex↗

Performance of the ISS-CREAM calorimeter in a calibration beam test

The Cosmic Ray Energetics And Mass experiment for the International Space Station (ISS-CREAM) was installed on the ISS to measure high-energy cosmic-ray elemental spectra for the charge range $\rm Z=1$ to 26. The ISS-CREAM instrument includes a tungsten scintillating-fiber calorimeter preceded by a carbon target for energy measurements. The carbon target induces hadronic interactions, and showers of secondary particles develop in the calorimeter. The energy deposition in the calorimeter is proportional to the particle energy. As a predecessor to ISS-CREAM, the balloon-borne CREAM instrument was successfully flown seven times over Antarctica for a cumulative exposure of 191 days. The CREAM calorimeter demonstrated its capability to measure energies of cosmic-ray particles, and the ISS-CREAM calorimeter is expected to have a similar performance. Before the launch, an engineering-unit calorimeter was shipped to CERN for calibration and performance tests. This beam test included position, energy, and angle scans of electron and pion beams together with a high-voltage scan for calibration and characterization. Additionally, an attenuation effect in the scintillating fibers was studied. In this paper, beam test results, including corrections for the attenuation effect, are presented.

physics.ins-det↗

An accelerator facility for intermediate energy proton irradiation and testing of nuclear materials

The bulk irradiation of materials with 10-30 MeV protons promises to advance the study of radiation damage for fission and fusion power plants. Intermediate energy proton beams can now be dedicated to materials irradiation within university-scale laboratories. This paper describes the first such facility, with an Ionetix ION-12SC cyclotron producing 12 MeV proton beams. Samples are mm-scale tensile specimens with thicknesses up to 300 um, mounted to a cooled beam target with control over temperature. A specialized tensile tester for radioactive specimens at high temperature (500+ °C) and/or vacuum represents the conditions in fission and fusion systems, while a digital image correlation system remotely measures strain. Overall, the facility provides university-scale irradiation and testing capability with intermediate energy protons to complement traditional in-core fission reactor and micro-scale ion irradiation. This facility demonstrates that bulk proton irradiation is a scalable and effective approach for nuclear materials research, down-selection, and qualification.

cond-mat.mtrl-sci↗

Total kinetic energy release in the fast neutron-induced fission of 237Np

The total kinetic energy (TKE) in the fast neutron induced fission of 237Np was measured for neutron energies from En = 2.6 - 100 MeV at the LANSCE-WNR facility. The post TKE release decreases non-linearly with increasing incident neutron energy and can be represented as TKE(MeV) = (174.38 +- 0.72) - (5.11 +- 0.5821) log10 En for En > 1 MeV. Analysis of the fragment mass distributions indicates that the decrease in TKE with increasing En is a consequence of two factors; shell effects fade out at high excitation energies, resulting in the increasing occurrence of symmetric fission, and TKEasym decreases rapidly at high En.

nucl-ex↗

Isotopically resolved neutron total cross sections at intermediate energies

The neutron total cross sections $σ_{tot}$ of $^{16,18}$O, $^{58,64}$Ni, $^{103}$Rh, and $^{112,124}$Sn have been measured at the Los Alamos Neutron Science Center (LANSCE) from low to intermediate energies (3 $\leq E_{lab} \leq$ 450 MeV) by leveraging waveform-digitizer technology. The $σ_{tot}$ relative differences between isotopes are presented, revealing additional information about the isovector components needed for an accurate optical-model description away from stability. Digitizer-enabled $σ_{tot}$-measurement techniques are discussed and a series of uncertainty-quantified dispersive optical model (DOM) analyses using these new data is presented, validating the use of the DOM for modeling light systems ($^{16,18}$O) and systems with open neutron shells ($^{58,64}$Ni and $^{112,124}$Sn). The valence-nucleon spectroscopic factors extracted for each isotope reaffirm the usefulness of high-energy proton reaction cross sections for characterizing depletion from the mean-field expectation.

nucl-ex↗

Total kinetic energy release in the fast neutron-induced fission of $^{235}$U

We have measured the total kinetic energy (TKE) release for the $^{235}$U(n,f) reaction for $E_{n}$=2-100 MeV using the 2E method with an array of Si PIN diode detectors. The neutron energies were determined by time of flight measurements using the white spectrum neutron beam at the LANSCE facility. To benchmark the TKE measurement, the TKE release for $^{235}$U(n$_{th}$,f) was also measured using a thermal neutron beam from the Oregon State University TRIGA reactor, giving pre-neutron emission $E^*_{TKE}=170.7\pm0.4$ MeV in good agreement with known values. Our measurements are thus absolute measurements. The TKE in $^{235}$U(n,f) decreases non-linearly from 169 MeV to 161 MeV for $E_{n}$=2-100 MeV. The multi-modal fission analysis of mass distributions and TKE indicates the origin of the TKE decrease with increasing neutron energy is a consequence of the fade out of asymmetric fission, which is associated with a higher TKE compared to symmetric fission. The average TKE associated with the superlong, standard I and standard II modes for a given mass is independent of neutron energy. The widths of the TKE distributions are constant from $E_{n}$=20-100 MeV and hence show no dependence with excitation energy.

nucl-ex↗

Total kinetic energy release in the fast neutron-induced fission of $^{235}$U

We have measured the total kinetic energy (TKE) release for the $^{235}$U(n,f) reaction for $E_{n}$=2-100 MeV using the 2E method with an array of Si PIN diode detectors. The neutron energies were determined by time of flight measurements using the white spectrum neutron beam at the LANSCE facility. (To calibrate the apparatus, the TKE release for $^{235}$U(n$_{th}$,f) was also measured using a thermal neutron beam from the OSU TRIGA reactor). The TKE decreases non-linearly from 169.0 MeV to 161.4 MeV for $E_{n}$=2-90 MeV. The standard deviation of the TKE distribution is constant from $E_{n}$=20-90 MeV. Comparison of the data with the multi-modal fission model of Brosa indicates the TKE decrease is a consequence of the growth of symmetric fission and the corresponding decrease of asymmetric fission with increasing neutron energy. The average TKE associated with the Brosa superlong, standard I and standard II modes for a given mass is independent of neutron energy.

nucl-ex↗

Proton and Helium Spectra from the CREAM-III Flight

Primary cosmic-ray elemental spectra have been measured with the balloon-borne Cosmic Ray Energetics And Mass (CREAM) experiment since 2004. The third CREAM payload (CREAM-III) flew for 29 days during the 2007-2008 Antarctic season. Energies of incident particles above 1 TeV are measured with a calorimeter. Individual elements are clearly separated with a charge resolution of ~0.12 e (in charge units) and ~0.14 e for protons and helium nuclei, respectively, using two layers of silicon charge detectors. The measured proton and helium energy spectra at the top of the atmosphere are harder than other existing measurements at a few tens of GeV. The relative abundance of protons to helium nuclei is 9.53+-0.03 for the range of 1 TeV/n to 63 TeV/n. The ratio is considerably smaller than other measurements at a few tens of GeV/n. The spectra become softer above ~20 TeV. However, our statistical uncertainties are large at these energies and more data are needed.

astro-ph.HE↗

The neutron long counter NERO for studies of beta-delayed neutron emission in the r-process

The neutron long counter NERO was built at the National Superconducting Cyclotron Laboratory (NSCL), Michigan State University, for measuring beta-delayed neutron-emission probabilities. The detector was designed to work in conjunction with a beta-decay implantation station, so that beta decays and beta-delayed neutrons emitted from implanted nuclei can be measured simultaneously. The high efficiency of about 40%, for the range of energies of interest, along with the small background, are crucial for measuring beta-delayed neutron emission branchings for neutron-rich r-process nuclei produced as low intensity fragmentation beams in in-flight separator facilities.

nucl-ex↗

Measurements of proton induced reaction cross sections on 120Te for the astrophysical p-process

The total cross sections for the 120Te(p,gamma)121I and 120Te(p,n)120I reactions have been measured by the activation method in the effective center-of-mass energies between 2.47 MeV and 7.93 MeV. The targets were prepared by evaporation of 99.4 % isotopically enriched 120Te on Aluminum and Carbon backing foils, and bombarded with proton beams provided by the FN tandem accelerator at the University of Notre Dame. The cross sections and $S$ factors were deduced from the observed gamma ray activity, which was detected off-line by two Clover HPGe detectors mounted in close geometry. The results are presented and compared with the predictions of statistical model calculations using the codes NON-SMOKER and TALYS.

nucl-ex↗